SPEC 44080

Southwire® RenewaFLEX™ Power Cables for Battery Energy Storage Systems

Single Conductor, Copper, 2000V, XLPE insulation Type RHH/RHW-2, Flexible Power Cable.

...

Construction:

  1. Conductor:Sizes 6 - 4/0 AWG: Class K, flexible stranded, bare copper per ASTM B3 and B172.
                        Sizes 250 - 1000 kcmil: Class I, flexible stranded, bare copper per ASTM B3 and B172.
  2. Insulation: Cross Linked Polyethylene (XLPE) Type RHH/RHW-2

Applications and Features:

Southwire’s 2000 Volt power cables are suited for use in the internal wiring of Battery Energy Storage Systems (BESS), in wet and dry locations, conduits, ducts, troughs, covered trays, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation, 130°C for emergency overload, and 250°C for short circuit conditions. Gasoline and Oil Resistant. For CT USE sizes 1/0 AWG and larger. Rated 1000 lb/ft maximum sidewall pressure.

Also available in different colors like: black, red, green, brown, yellow, etc.

Specifications:

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors
  • UL 44 Thermoset-Insulated Wires and Cables
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
  • RoHS-3 Complies with European Directive 2015/863
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661
  • Sample Print Legend:

    For 8 - 2 AWG:
    {SQFTG} SOUTHWIRE E30117 {UL} XX AWG CU TYPE RHH OR RHW-2 XX MILS XLP PRI/II GRI/II 2000 VOLTS

    For 1/0 - 4/0 AWG:
    {SQFTG} SOUTHWIRE E30117 {UL} XX AWG CU TYPE RHH OR RHW-2 XX MILS XLP FOR CT USE PRI/II GRI/II 2000 VOLTS

    For 250 -1000 kcmil:
    {SQFTG} SOUTHWIRE E30117 {UL} XX kcmil CU TYPE RHH OR RHW-2 XX MILS XLP FOR CT USE PRI/II GRI/II 2000 VOLTS
    Table 1 – Weights and Measurements
    Stock NumberCond. SizeStrandInsul. ThicknessApprox. ODApprox. WeightMin Bending RadiusMax Pull TensionDC Resistance @ 25°CAC Resistance @ 75°CInductive Reactance @ 60HzAllowable Ampacity In Raceway 90°CJacket Color
    AWG/KcmilNo.milinchlb/1000ftinchlbΩ/1000ftΩ/1000ftΩ/1000ftAmp
    TBA8168700.293731.21320.6660.8270.05255OE
    6657776259700.3271251.32090.4190.520.05175OE
    6657764413700.3831741.53330.2630.3260.04895OE
    6657752665700.4482621.85300.1670.2070.045130OE
    6654221/01064900.5584162.28440.1050.130.044170OE
    1389232/01330900.615102.410640.0850.1050.043195OE
    1389244/02109900.717722.816920.0530.0660.041260OE
    1389252506271050.8259093.320000.0450.0560.041290OE
    1389263508931050.8912423.628000.0320.0410.04350OE
    13892750012211051.07817105.440000.0220.0290.039430OE
    13895060014801201.21521126.148000.0180.0240.039475OE
    13895175018501201.34626506.760000.0150.0210.038535OE
    516431777.719241201.28227346.462210.0150.0210.038543RD
    516430777.719241201.28227346.462210.0150.0210.038543BK
    516432777.719241201.28227346.462210.0150.0210.038543GN
    TBA100025161201.4332597.280000.0110.0160.037615OE
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item
    • TBA stock codes are estimations only and actual product may vary. Please wait until a stock code is assigned to purchase connectors and/or fittings.
    Table 2 – Weights and Measurements (Metric)
    Stock NumberCond. SizeStrandInsul. ThicknessApprox. ODApprox. WeightMin Bending RadiusMax Pull TensionDC Resistance @ 25°CAC Resistance @ 75°CInductive Reactance @ 60HzAllowable Ampacity In Raceway 90°CJacket Color
    AWG/KcmilNo.mmmmkg/kmmmnewtonΩ/kmΩ/kmΩ/kmAmp
    TBA81681.787.4410930.485872.192.710.170655OE
    66577762591.788.3118633.029301.371.710.167375OE
    66577644131.789.7325938.1014820.861.070.157595OE
    66577526651.7811.3839045.7223590.550.680.1476130OE
    6654221/010642.2914.1761955.8837560.340.430.1444170OE
    1389232/013302.2915.4975960.9647350.280.340.1411195OE
    1389244/021092.2918.03114971.1275290.170.220.1345260OE
    1389252506272.6720.96135383.8289000.150.180.1345290OE
    1389263508932.6722.61184891.44124600.100.130.1312350OE
    13892750012212.6727.382545137.16178000.070.100.1280430OE
    13895060014803.0530.863143154.94213600.060.080.1280475OE
    13895175018503.0534.193944170.18267000.050.070.1247535OE
    516431777.719243.0532.564069162.56276830.050.070.1247543RD
    516430777.719243.0532.564069162.56276830.050.070.1247543BK
    516432777.719243.0532.564069162.56276830.050.070.1247543GN
    TBA100025163.0536.324850182.88356000.040.050.1214615OE
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item
    • TBA stock codes are estimations only and actual product may vary. Please wait until a stock code is assigned to purchase connectors and/or fittings.

    Revision: 1.000.078

    Updated On: Nov. 18, 2026, 3:54 p.m. UTC