SPEC 45309
CU 600/1000V XLPE Insulation 50% Ground AIA PVC Jacket XHHW-2. CT Rated -Sunlight Resistant - For Direct Burial - Silicone Free
Type MC Power Cable 600Volt Four Conductor Copper, Cross Linked Polyethylene (XLPE) insulation XHHW-2 Three Bare CU 50% Ground Aluminum Interlocked Armor (AIA), Polyvinyl Chloride (PVC) Jacket. Silicone Free.

Construction:
- Conductor:Class B compressed stranded bare copper per ASTM B3 and ASTM B8
- Insulation:Cross Linked Polyethylene (XLPE) Type XHHW-2
- Grounding Conductor:Class B compressed stranded bare copper per ASTM B3 and ASTM B8
- Filler:Paper filler
- Binder:Polypropylene tape
- Armor:Aluminum Interlocked Armor (AIA)
- Overall Jacket:Polyvinyl Chloride (PVC) Jacket
Applications and Features:
Southwire’s 600 Volt Type MC power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of op- erating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. The ground is sized to 50% of the phase conductor with three separate bare grounds one in each interstecie between condutors. Silicone Free.
Specifications:
Sample Print Legend:
{SQFTG_DUAL} SOUTHWIRE {UL} 4/C (XXX KCMIL) XXXmm2 CU 65 MILS XLP 600 VOLTS GW 3 X 1 AWG CU TYPE MC FOR CT USE SUN. RES. DIRECT BURIAL 90°C USA -- {NOM}-ANCE Tipo MC XHHW-2 CT
Table 1 – Weights and Measurements
| Stock Number | Cond. Size | Cond. Number | Strand Count | Diameter Over Conductor | Insul. Thickness | Ground | Diameter Over Armor | Jacket Thickness | Approx. OD | Copper Weight | Approx. Weight | Jacket Color |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| AWG/Kcmil | No. of Strands | inch | mil | No. x AWG | inch | mil | inch | lb/1000ft | lb/1000ft | |||
| 665399 | 1/0 | 4 | 19 | 0.362 | 55 | 3 x 6 | 1.382 | 50 | 1.487 | 1563 | 2046 | BK |
| TBA | 2/0 | 4 | 19 | 0.405 | 55 | 3 x 6 | 1.459 | 50 | 1.559 | BK | ||
| TBA | 3/0 | 4 | 19 | 0.456 | 55 | 3 x 5 | 1.683 | 50 | 1.783 | BK | ||
| 665402 | 4/0 | 4 | 19 | 0.512 | 55 | 3 x 4 | 1.815 | 60 | 1.941 | 3030 | 3755 | BK |
| 665410 | 250 | 4 | 37 | 0.558 | 65 | 3 x 4 | 1.964 | 60 | 2.09 | 3509 | 4325 | BK |
| TBA | 350 | 4 | 37 | 0.661 | 65 | 3 x 2 | 2.227 | 60 | 2.347 | BK | ||
| 952374 | 500 | 4 | 37 | 0.789 | 65 | 3 x 1 | 2.505 | 75 | 2.663 | 7020 | 8244 | BK |
| TBA | 600 | 4 | 61 | 0.866 | 80 | 3 x 1/0 | 2.796 | 75 | 2.946 | BK | ||
| TBA | 750 | 4 | 61 | 0.968 | 80 | 3 x 2/0 | 3.043 | 75 | 3.193 | BK |
All dimensions are nominal and subject to normal manufacturing tolerances
◊ Cable marked with this symbol is a standard stock item
TBA stock codes are estimations only and actual product may vary. Please wait until a stock code is assigned to purchase connectors and/or fittings.
Table 2 – Electrical and Engineering Data
| Stock Number | Cond. Size | Cond. Number | Min Bending Radius | Max Pull Tension | DC Resistance @ 25°C | AC Resistance @ 75°C | Inductive Reactance @ 60Hz | Allowable Ampacity At 75°C | Allowable Ampacity At 90°C |
|---|---|---|---|---|---|---|---|---|---|
| AWG/Kcmil | inch | lb | Ω/1000ft | Ω/1000ft | Ω/1000ft | Amp | Amp | ||
| 665399 | 1/0 | 4 | 10.4 | 3379 | 0.102 | 0.127 | 0.044 | 120 | 136 |
| TBA | 2/0 | 4 | 10.9 | 4259 | 0.082 | 0.102 | 0.043 | 140 | 156 |
| TBA | 3/0 | 4 | 12.5 | 5369 | 0.064 | 0.079 | 0.042 | 160 | 180 |
| 665402 | 4/0 | 4 | 13.6 | 6771 | 0.051 | 0.063 | 0.041 | 184 | 208 |
| 665410 | 250 | 4 | 14.6 | 8000 | 0.043 | 0.053 | 0.041 | 204 | 232 |
| TBA | 350 | 4 | 16.4 | 11200 | 0.031 | 0.039 | 0.04 | 248 | 280 |
| 952374 | 500 | 4 | 18.6 | 16000 | 0.021 | 0.027 | 0.039 | 304 | 344 |
| TBA | 600 | 4 | 20.6 | 19200 | 0.018 | 0.024 | 0.039 | 336 | 380 |
| TBA | 750 | 4 | 22.4 | 24000 | 0.014 | 0.019 | 0.038 | 380 | 428 |
* Ampacities based upon 2023 NEC Table 310.16. See NEC sections 310.15 and 110.14(C) for additional requirements.
* Ampacities have been adjusted for more than Three Current-Carrying Conductors.
* Ampacities have been adjusted for more than Three Current-Carrying Conductors.