Toggle navigation
Submit an Idea
Products
Industrial
Utility
Residential and Commercial
Innovation
Sustainability
Tech Blog
My Products
COMEX CU
Close:
4.8055
Products
>
Industrial
> LV and MV Armor
Canada
United States
Canada
International
LV and MV Armor
Cable Type
3/C MV AIA
3/C MV ARMOR-X
3/C MV GSIA
LV AIA
LV ARMOR-X
SPOS
STOS
TECK
Conductor Type
Copper
Aluminum
Voltage
600V
1000V
2400V
5000V
8000V
15000V
25000V
35000V
Number of Conductor
1C
2C
3C
4C
8C
12C
16C
24C
36C
Apply Filter
SPEC: 43701
600V CU PVC TRIADS ARMOR-X
®
PVC STOS Instrumentation
Add to My Products
SPEC: 43702
600V CU PVC PAIRS ARMOR-X
®
PVC SPOS Instrumentation
Add to My Products
SPEC: 43705
600V CU PVC PAIRS ARMOR-X
®
SOLONON
®
LSZH SPOS Instrumentation
Add to My Products
SPEC: 43706
600V CU PVC TRIADS ARMOR-X
®
SOLONON
®
LSZH STOS Instrumentation
Add to My Products
SPEC: 45226
CU 600V XLPE Insulation ARMOR-X
®
PVC Jacket XHHW-2 VFD Cable. CT Rated - Sunlight Resistant - For Direct Burial - Silicone Free
Add to My Products
SPEC: 45351
CU 600/1000V XLPE Insulation ARMOR-X
®
PVC Jacket XHHW-2. VFD Cable - CT Rated -Sunlight Resistant - For Direct Burial - Silicone Free
Add to My Products
SPEC: 45360
CU 600/1000V XLPE Insulation PVC AIA PVC Jacket XHHW-2. Teck - CT Rated -Sunlight Resistant - For Direct Burial - Silicone Free
Add to My Products
SPEC: 46026
CU Compressed 2.4kV NLEPR Insulation 100% IL AIA PVC Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial
Add to My Products
SPEC: 46027
CU Compressed 2.4kV NLEPR Insulation 100% IL ARMOR-X
®
PVC Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial - VFD Cable
Add to My Products
SPEC: 46253
CU Compressed 5/8kV NLEPR Insulation 133/100% IL GSIA PVC Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial
Add to My Products
SPEC: 46254
CU Compressed 5/8kV NLEPR Insulation 133/100% IL AIA PVC Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial
Add to My Products
SPEC: 46255
CU Compressed 5/8kV NLEPR Insulation 133/100% IL ARMOR-X
®
PVC Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial - VFD Cable
Add to My Products
SPEC: 46257
AL Compact 5/8kV NLEPR Insulation 133/100% IL AIA PVC Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial
Add to My Products
SPEC: 46258
CU Compressed 5/8kV NLEPR Insulation 133/100% IL AIA LSZH-TP Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial
Add to My Products
SPEC: 46259
CU Compressed 5/8kV NLEPR Insulation 133/100% IL AIA CPE-TP Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial
Add to My Products
SPEC: 46280
CU Compressed 8kV NLEPR Insulation 133% IL AIA PVC Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial
Add to My Products
SPEC: 46284
CU Compressed 8kV NLEPR Insulation 133% IL ARMOR-X
®
PVC Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial - VFD Cable
Add to My Products
SPEC: 46451
CU Compressed 15kV NLEPR Insulation 100% IL AIA Red PVC Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial
Add to My Products
SPEC: 46453
CU Compressed 15kV NLEPR Insulation 133% IL AIA Red PVC Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial
Add to My Products
SPEC: 46454
CU Compressed 15kV NLEPR Insulation 133% IL ARMOR-X
®
Red PVC Jacket. MV 105 Tray Rated - Sunlight Resistant - For Direct Burial
Add to My Products
SPEC: 46455
CU Compressed 15kV NLEPR Insulation 133% IL AIA Red PVC Jacket. MV 105 - 50% Ground - Tray Rated - Sunlight Resistant - For Direct Burial
Add to My Products
SPEC: 46456
CU Compressed 15kV NLEPR Insulation 133% IL Three Grounds, ARMOR-X
®
Red PVC Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial
Add to My Products
SPEC: 46457
AL Compact 15kV NLEPR Insulation 133% IL AIA Black PVC Jacket. MV 105 - 50% Ground - Tray Rated - Sunlight Resistant - For Direct Burial
Add to My Products
SPEC: 46459
AL Compact 15kV NLEPR Insulation 133% IL AIA Red PVC Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial
Add to My Products
SPEC: 46460
CU Compressed 15kV NLEPR Insulation 133% IL AIA Red LSZH-TP Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial
Add to My Products
SPEC: 46461
CU Compressed 15kV NLEPR Insulation 133% IL AIA Red CPE-TP Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial
Add to My Products
SPEC: 46462
CU Compressed 15kV NLEPR Insulation 133% IL GSIA Red PVC Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial
Add to My Products
SPEC: 46468
CU Compressed 15kV NLEPR Insulation 133% IL AIA Black PVC Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial
Add to My Products
SPEC: 46469
CU Compressed 15kV NLEPR Insulation 133% IL AIA Black CPE Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial
Add to My Products
SPEC: 46470
AL Compact 15kV NLEPR Insulation 173% IL AIA Black PVC Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial
Add to My Products
SPEC: 46653
CU Compressed 25kV NLEPR Insulation 133% IL AIA Orange PVC Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial
Add to My Products
SPEC: 46654
CU Compressed 25kV NLEPR Insulation 133% IL ARMOR-X
®
Orange PVC Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial
Add to My Products
SPEC: 46852
CU Compressed 35kV NLEPR Insulation 100% IL ARMOR-X
®
Orange PVC Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial
Add to My Products
SPEC: 46854
CU Compressed 35kV NLEPR Insulation 133% IL ARMOR-X
®
Orange PVC Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial
Add to My Products
SPEC: 46862
AL Compact 35kV NLEPR Insulation 133% IL ARMOR-X
®
Orange PVC Jacket. MV 105 - Tray Rated - Sunlight Resistant - For Direct Burial
Add to My Products