SPEC 70305

Royal® EXCELENE ® NON-UL WELDING CABLE. Silicone Free

600 Volt 105°C Flexible Cord. Heat, Abrasion, Tear Resistant, Moisture and Flexible EPDM Jacket.

...

Construction:

  1. Conductor:Annealed flexible soft drawn bare copper per ASTM B3.
  2. Separator:Paper separator for ease of stripability
  3. Insulation:EPDM, Black (Other colors available upon request)

Applications and Features:

Southwire Excelene® Welding cable, extra flexible, rated for -50°C to 105°C temperatures. This cable used for secondary voltage resistance welding cable leads, National electrical code Article 630 electric welders and for temporary power industrial applications.

Specifications:

  • RoHS Compliant Lead-Free, Silicone-Free
  • Sample Print Legend:

    SOUTHWIRE® ROYAL® EXCELENE® XXX KCMIL (XXXmm2) WELDING CABLE 600V -50C TO +105C MADE IN USA--Sequential Footage Marking--

    Packaging:

    Standard lengths: 250', 500' and 1,000' reels. Other lengths available upon request.
    Table 1 – Weights and Measurements
    Stock NumberCond. SizeCond. NumberCond. StrandsJacket ThicknessApprox. ODApprox. WeightAmpacityInsul. Color
    AWG/KcmilNo.No.milinchlb/1000ftAmp
    10410081135700.2858080BK
    10411061259650.305120105BK
    10412041385600.340167140BK
    10483021651700.420260190BK
    10413021651700.420260190BK
    10484011798850.498334220BK
    10414011798850.498334220BK
    1048501/011026850.525411260BK
    1041501/011026850.525411260BK
    1041602/011254850.570465300BK
    1048703/011615800.617609350BK
    1041703/011615900.635617350BK
    1048804/012052800.695773405BK
    1041804/012052800.695773405BK
    TBA250124511450.712821455BK
    TBA350134581350.8241130570BK
    TBA500149211600.9971630700BK
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item
    * Ampacities are based on TABLE 400.5(A)(2) of the 2023 National Electrical Code and CEC Table 12(A). The ampacity values assume a continuous sinusoidal 60 Hz current and are for reference only and should not be used as a final value.
    Table 2 – Weights and Measurements (Metric)
    Stock NumberCond. SizeCond. NumberCond. StrandsJacket ThicknessApprox. ODApprox. WeightAmpacity *Insul. Color
    AWG/KcmilNo.No.mmmmkg/kmAmp
    104100811351.787.2411980BK
    104110612591.657.75179105BK
    104120413851.528.64249140BK
    104830216511.7810.67387190BK
    104130216511.7810.67387190BK
    104840117982.1612.65497220BK
    104140117982.1612.65497220BK
    1048501/0110262.1613.33612260BK
    1041501/0110262.1613.33612260BK
    1041602/0112542.1614.48692300BK
    1048703/0116152.0315.67906350BK
    1041703/0116152.2916.13918350BK
    1048804/0120522.0317.651150405BK
    1041804/0120522.0317.651150405BK
    TBA250124513.6818.081222455BK
    TBA350134583.4320.931682570BK
    TBA500149214.0625.322426700BK