SPEC 70305

Royal® EXCELENE® NON-UL WELDING CABLE. Silicone Free and Halogen Free

600 Volt 105°C Flexible Cord. Heat, Abrasion, Tear Resistant, Moisture and Flexible EPDM Insulation. Silicone Free and Halogen Free

...

Construction:

  1. Conductor:Annealed flexible soft drawn bare copper per ASTM B3
  2. Separator:Paper separator for ease of stripability
  3. Insulation:Black, silicone-free, and halogen-free EPDM (Other colors available upon request)

Applications and Features:

Southwire Excelene® Welding cable are extra flexible and rated for temperatures -50°C to 105°C. This cable used for secondary voltage resistance welding cable leads per National Electrical Code Article 630 electric welders and for temporary power industrial applications.

Specifications:

  • ASTM B3 Soft or Annealed Copper Wire
  • RoHS Compliant Lead-Free, Silicone-Free, Halogen Free
  • Sample Print Legend:

    With Metric Print:
    {SQFTG} SOUTHWIRE® ROYAL® EXCELENE® XX (XXmm2) WELDING CABLE 600V -50C TO +105C MADE IN USA

    No Metric Print:
    {SQFTG} SOUTHWIRE® ROYAL® EXCELENE® XX WELDING CABLE 600V -50C TO +105C MADE IN USA

    Packaging:

    Standard lengths: 250', 500' and 1,000' reels. Other lengths available upon request.
    Table 1 – Weights and Measurements
    Stock NumberCond. SizeCond. NumberCond. StrandsJacket ThicknessApprox. ODApprox. WeightAmpacityInsul. Color
    AWG/KcmilNo.No.milinchlb/1000ftAmp
    1041081135700.2858080BK
    1041161259650.305120105BK
    1041241385600.340167140BK
    1041321651700.420260190BK
    10483^21651700.420260190BK
    10484^11798850.498334220BK
    1041411798850.498334220BK
    104151/011026850.525411260BK
    10485^1/011026850.525411260BK
    104162/011254850.570465300BK
    10487^3/011615800.617609350BK
    104173/011615900.635617350BK
    104184/012052800.695773405BK
    10488^4/012052800.695773405BK
    F25001250124511450.8751015455BK
    F35003350134581350.9751310570BK
    F50001500149211601.1501879700BK
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item
    * Ampacities are based on TABLE 400.5(A)(2) of the 2023 National Electrical Code and CEC Table 12(A). The ampacity values assume a continuous sinusoidal 60 Hz current and are for reference only and should not be used as a final value.
    TBA stock codes are estimations only and actual product may vary. Please wait until a stock code is assigned to purchase connectors and/or fittings.
    ^ No metric print
    Table 2 – Weights and Measurements (Metric)
    Stock NumberCond. SizeCond. NumberCond. StrandsJacket ThicknessApprox. ODApprox. WeightAmpacity *Insul. Color
    AWG/KcmilNo.No.mmmmkg/kmAmp
    10410811351.787.2411980BK
    10411612591.657.75179105BK
    10412413851.528.64249140BK
    10413216511.7810.67387190BK
    10483^216511.7810.67387190BK
    10484^117982.1612.65497220BK
    10414117982.1612.65497220BK
    104151/0110262.1613.33612260BK
    10485^1/0110262.1613.33612260BK
    104162/0112542.1614.48692300BK
    10487^3/0116152.0315.67906350BK
    104173/0116152.2916.13918350BK
    104184/0120522.0317.651150405BK
    10488^4/0120522.0317.651150405BK
    F25001250124513.6822.221510455BK
    F35003350134583.4324.761949570BK
    F50001500149214.0629.212796700BK