SPEC 10090
CU 150V HVAC Wire Unshielded Thermostat CL2/CMH
CU 150V HDPE Insulation PVC Jacket CL2/CMH Power Limited Unshielded Thermostat Wire

Construction:
- Conductor:Solid bare copper per ASTM B3
- Insulation:High Density Polyethylene HDPE
- Rip Cord:Rip cord for ease of jacket strip ability
- Overall Jacket:Polyvinyl Chloride (PVC) Jacket in Brown
Applications and Features:
Specifications:
Sample Print Legend:
TYPE CL2 C{ETL}US XX AWG XX/C BAROSTAT II SUN RES -- TYPE CMH FT1 -- {MM/DD/YY} {HH:MM}
Table 1 – Physical and Electrical Data
| Stock Number | Cond. Size | Cond. Number | Cond. Strands | Diameter Over Cond. | Insulation Color | Insul. Thickness | Jacket Thickness | Approx. OD | Copper Weight | Approx. Weight | DC Resistance @ 25°C | AC Resistance @ 75°C | Inductive Rectance | Min Bending Radius | Jacket Color | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| AWG | No. | strands | inch | mil | mil | inch | lb/1000ft | lb/1000ft | Ω/1000ft | Ω/1000ft | Ω/1000ft | inch | |||||||
| 20 AWG | |||||||||||||||||||
| 55202◊ | 20 | 2 | SOLID | 0.032 | RD,WE | 5 | 14 | 0.114 | 6 | 9 | 10.503 | 12.655 | 0.027 | 0.5 | BN | ||||
| 55203◊ | 20 | 3 | SOLID | 0.032 | RD,WE,GN | 5 | 14 | 0.121 | 9 | 13 | 10.503 | 12.655 | 0.027 | 0.5 | BN | ||||
| 55204◊ | 20 | 4 | SOLID | 0.032 | RD,WE,GN,BE | 5 | 14 | 0.132 | 12 | 16 | 10.503 | 12.655 | 0.027 | 0.5 | BN | ||||
| 55205◊ | 20 | 5 | SOLID | 0.032 | RD,WE,GN,BE,YW | 5 | 15 | 0.147 | 15 | 20 | 10.503 | 12.655 | 0.027 | 0.6 | BN | ||||
| 55206◊ | 20 | 6 | SOLID | 0.032 | RD,WE,GN,BE,YW,BN | 5 | 15 | 0.16 | 18 | 24 | 10.503 | 12.655 | 0.027 | 0.6 | BN | ||||
| 55207◊ | 20 | 7 | SOLID | 0.032 | RD,WE,GN,BE,YW,BN,OE | 5 | 15 | 0.16 | 18 | 27 | 10.503 | 12.655 | 0.027 | 0.6 | BN | ||||
| 55210◊ | 20 | 10 | SOLID | 0.032 | RD,WE,GN,BE,YW,BN,OE,BK,PK,GY | 5 | 15 | 0.202 | 30 | 38 | 10.503 | 12.655 | 0.027 | 0.8 | BN | ||||
| 55212◊ | 20 | 12 | SOLID | 0.032 | RD,WE,GN,BE,YW,BN,OE,BK,PK,GY,TN,PE | 5 | 15 | 0.209 | 36 | 42 | 10.503 | 12.655 | 0.027 | 0.8 | BN | ||||
| 18 AWG | |||||||||||||||||||
| 55302◊ | 18 | 2 | SOLID | 0.04 | RD,WE | 5 | 14 | 0.132 | 10 | 14 | 6.659 | 8.265 | 0.036 | 0.5 | BN | ||||
| 55303◊ | 18 | 3 | SOLID | 0.04 | RD,WE,GN | 5 | 14 | 0.14 | 15 | 19 | 6.659 | 8.265 | 0.036 | 0.6 | BN | ||||
| 55304◊ | 18 | 4 | SOLID | 0.04 | RD,WE,GN,BE | 5 | 14 | 0.154 | 19 | 25 | 6.659 | 8.265 | 0.036 | 0.6 | BN | ||||
| 55305◊ | 18 | 5 | SOLID | 0.04 | RD,WE,GN,BE,YW | 5 | 15 | 0.17 | 24 | 30 | 6.659 | 8.265 | 0.036 | 0.7 | BN | ||||
| 55306◊ | 18 | 6 | SOLID | 0.04 | RD,WE,GN,BE,YW,BN | 5 | 15 | 0.186 | 29 | 37 | 6.659 | 8.265 | 0.036 | 0.74 | BN | ||||
| 55307◊ | 18 | 7 | SOLID | 0.04 | RD,WE,GN,BE,YW,BN,OE | 5 | 15 | 0.186 | 34 | 41 | 6.659 | 8.265 | 0.036 | 0.7 | BN | ||||
| 55308◊ | 18 | 8 | SOLID | 0.04 | RD,WE,GN,BE,YW,BN,OE,BK | 5 | 15 | 0.202 | 29 | 48 | 6.659 | 8.265 | 0.036 | 0.8 | BN | ||||
| 55310◊ | 18 | 10 | SOLID | 0.04 | RD,WE,GN,BE,YW,BN,OE,BK,PK,GY | 5 | 15 | 0.238 | 48 | 58 | 6.659 | 8.265 | 0.036 | 1 | BN | ||||
| 55312◊ | 18 | 12 | SOLID | 0.04 | RD,WE,GN,BE,YW,BN,OE,BK,PK,GY,TN,PE | 5 | 15 | 0.245 | 58 | 69 | 6.659 | 8.265 | 0.036 | 1 | BN | ||||
All dimensions are nominal and subject to normal manufacturing tolerances
◊ Cable marked with this symbol is a standard stock item
TBA stock codes are estimations only and actual product may vary. Please wait until a stock code is assigned to purchase connectors and/or fittings.
Revision: 1.000.010
Updated On: April 1, 2025, 11:18 p.m. UTC


