SPEC 80113
ACSS/AW
Aluminum Conductor, Aluminum-Clad Steel Supported

Construction:
- Core: Stranded aluminum-clad steel core, available in AW2 normal-strength and AW3 high-strength classes
- Stranding: Annealed aluminum (1350-O) round wires with 63% conductivity
Applications and Features:
ACSS/AW (Aluminum Conductor, Aluminum-Clad Steel Supported) is a concentrically stranded, high-temperature overhead conductor consisting of fully annealed aluminum wires surrounding an aluminum-clad steel core. The annealed aluminum provides electrical conductivity, while the aluminum-clad steel core carries the conductor’s mechanical load.
Southwire batch anneals the completed conductor after stranding, allowing the aluminum to be fully annealed while supporting tighter stranding and verification of finished conductor properties after heat exposure.
The aluminum cladding provides additional core conductivity and corrosion protection. ACSS/AW is suitable for overhead transmission and distribution applications requiring increased ampacity, controlled thermal sag, and enhanced corrosion performance. It can be used for new construction, reconductoring, coastal environments, and other applications where an aluminum-clad steel core is preferred.
Continuous operating temperature - 250°C
Southwire batch anneals the completed conductor after stranding, allowing the aluminum to be fully annealed while supporting tighter stranding and verification of finished conductor properties after heat exposure.
The aluminum cladding provides additional core conductivity and corrosion protection. ACSS/AW is suitable for overhead transmission and distribution applications requiring increased ampacity, controlled thermal sag, and enhanced corrosion performance. It can be used for new construction, reconductoring, coastal environments, and other applications where an aluminum-clad steel core is preferred.
Continuous operating temperature - 250°C
Specifications:
Weights, Measurements, Electrical and Engineering Data
| Stock Number | Code Word | Conductor Size | Stranding | Cross-Sectional Area | Layers of Al | Diameter | Weight | Rated Breaking Strength | DC Resistance @ 20°C | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Individual Strands | AW Core | Complete Conductor | |||||||||||||
| Al | Total | Al | AW | Al | Total | AW2 | AW3 | ||||||||
| kcmil | Al/AW | in² | in² | in | in | in | in | lb/1000ft | lb/1000ft | lb | lb | Ω/mile | |||
| TBA | PARTRIDGE/ACSS/AW | 266.8 | 26/7 | 0.2095 | 0.2436 | 2 | 0.1013 | 0.0788 | 0.2364 | 0.642 | 251.2 | 349.0 | 8,370 | 8,880 | 0.3170 |
| TBA | JUNCO/ACSS/AW | 266.8 | 30/7 | 0.2095 | 0.2584 | 2 | 0.0943 | 0.0943 | 0.2829 | 0.660 | 251.9 | 392.2 | 11,200 | 11,700 | 0.3109 |
| TBA | OSTRICH/ACSS/AW | 300.0 | 26/7 | 0.2355 | 0.2738 | 2 | 0.1074 | 0.0835 | 0.2505 | 0.680 | 282.4 | 392.3 | 9,400 | 9,970 | 0.2820 |
| TBA | WIDGEON/ACSS/AW | 336.4 | 24/7 | 0.2642 | 0.2984 | 2 | 0.1184 | 0.0789 | 0.2367 | 0.710 | 316.8 | 414.9 | 8,830 | 9,340 | 0.2540 |
| TBA | LINNET/ACSS/AW | 336.4 | 26/7 | 0.2640 | 0.3070 | 2 | 0.1137 | 0.0884 | 0.2652 | 0.720 | 316.6 | 440.0 | 10,500 | 11,200 | 0.2515 |
| TBA | ORIOLE/ACSS/AW | 336.4 | 30/7 | 0.2642 | 0.3259 | 2 | 0.1059 | 0.1059 | 0.3177 | 0.741 | 317.6 | 494.6 | 14,200 | 14,800 | 0.2465 |
| TBA | BRANT/ACSS/AW | 397.5 | 24/7 | 0.3122 | 0.3527 | 2 | 0.1287 | 0.0858 | 0.2574 | 0.772 | 374.4 | 490.6 | 10,400 | 11,000 | 0.2149 |
| TBA | IBIS/ACSS/AW | 397.5 | 26/7 | 0.3120 | 0.3628 | 2 | 0.1236 | 0.0961 | 0.2883 | 0.783 | 374.2 | 519.9 | 12,400 | 13,000 | 0.2129 |
| TBA | LARK/ACSS/AW | 397.5 | 30/7 | 0.3121 | 0.3849 | 2 | 0.1151 | 0.1151 | 0.3453 | 0.806 | 375.2 | 584.0 | 16,700 | 17,500 | 0.2087 |
| TBA | TOUCAN/ACSS/AW | 477.0 | 22/7 | 0.3744 | 0.4112 | 2 | 0.1472 | 0.0818 | 0.2454 | 0.834 | 449.0 | 554.6 | 10,200 | 10,800 | 0.1810 |
| TBA | FLICKER/ACSS/AW | 477.0 | 24/7 | 0.3747 | 0.4233 | 2 | 0.1410 | 0.0940 | 0.2820 | 0.846 | 449.4 | 588.8 | 12,500 | 13,000 | 0.1791 |
| TBA | HAWK/ACSS/AW | 477.0 | 26/7 | 0.3744 | 0.4354 | 2 | 0.1354 | 0.1053 | 0.3159 | 0.858 | 449.0 | 624.0 | 14,900 | 15,600 | 0.1774 |
| TBA | HEN/ACSS/AW | 477.0 | 30/7 | 0.3747 | 0.4621 | 2 | 0.1261 | 0.1261 | 0.3783 | 0.883 | 450.5 | 701.2 | 20,100 | 20,500 | 0.1738 |
| TBA | HERON/ACSS/AW | 500.0 | 30/7 | 0.3927 | 0.4843 | 2 | 0.1291 | 0.1291 | 0.3873 | 0.904 | 472.1 | 734.9 | 20,600 | 21,500 | 0.1658 |
| TBA | SAPSUCKER/ACSS/AW | 556.5 | 22/7 | 0.4368 | 0.4797 | 2 | 0.1590 | 0.0883 | 0.2649 | 0.901 | 523.8 | 646.9 | 11,900 | 12,600 | 0.1552 |
| TBA | PARAKEET/ACSS/AW | 556.5 | 24/7 | 0.4372 | 0.4938 | 2 | 0.1523 | 0.1015 | 0.3045 | 0.914 | 524.3 | 686.7 | 14,600 | 15,200 | 0.1535 |
| TBA | DOVE/ACSS/AW | 556.5 | 26/7 | 0.4371 | 0.5083 | 2 | 0.1463 | 0.1138 | 0.3414 | 0.927 | 524.2 | 728.4 | 17,500 | 18,200 | 0.1519 |
| TBA | EAGLE/ACSS/AW | 556.5 | 30/7 | 0.4371 | 0.5391 | 2 | 0.1362 | 0.1362 | 0.4086 | 0.953 | 525.5 | 818.1 | 22,900 | 24,000 | 0.1490 |
| TBA | PEACOCK/ACSS/AW | 605.0 | 24/7 | 0.4753 | 0.5370 | 2 | 0.1588 | 0.1059 | 0.3177 | 0.953 | 570.0 | 747.0 | 15,900 | 16,500 | 0.1412 |
| TBA | SQUAB/ACSS/AW | 605.0 | 26/7 | 0.4749 | 0.5522 | 2 | 0.1525 | 0.1186 | 0.3558 | 0.966 | 569.5 | 791.2 | 19,000 | 19,700 | 0.1398 |
| TBA | WOOD DUCK/ACSS/AW | 605.0 | 30/7 | 0.4751 | 0.5860 | 2 | 0.1420 | 0.1420 | 0.4260 | 0.994 | 571.2 | 889.3 | 24,400 | 25,500 | 0.1371 |
| TBA | TEAL/ACSS/AW | 605.0 | 30/19 | 0.4751 | 0.5834 | 2 | 0.1420 | 0.0852 | 0.4260 | 0.994 | 571.2 | 882.5 | 25,000 | 26,600 | 0.1373 |
| TBA | DUCK/ACSS/AW | 605.0 | 54/7 | 0.4747 | 0.5362 | 3 | 0.1058 | 0.1058 | 0.3174 | 0.952 | 569.3 | 745.7 | 15,900 | 16,500 | 0.1414 |
| TBA | TURACOS/ACSS/AW | 636.0 | 20/7 | 0.4994 | 0.5339 | 2 | 0.1783 | 0.0792 | 0.2376 | 0.951 | 598.9 | 697.9 | 10,800 | 11,300 | 0.1370 |
| TBA | GOLDFINCH/ACSS/AW | 636.0 | 22/7 | 0.4994 | 0.5484 | 2 | 0.1700 | 0.0944 | 0.2832 | 0.963 | 598.9 | 739.5 | 13,600 | 14,100 | 0.1357 |
| TBA | ROOK/ACSS/AW | 636.0 | 24/7 | 0.4996 | 0.5643 | 2 | 0.1628 | 0.1085 | 0.3255 | 0.977 | 599.1 | 784.7 | 16,700 | 17,300 | 0.1343 |
| TBA | GROSBEAK/ACSS/AW | 636.0 | 26/7 | 0.4995 | 0.5808 | 2 | 0.1564 | 0.1216 | 0.3648 | 0.990 | 599.0 | 832.2 | 19,900 | 20,300 | 0.1330 |
| TBA | SCOTER/ACSS/AW | 636.0 | 30/7 | 0.4995 | 0.6160 | 2 | 0.1456 | 0.1456 | 0.4368 | 1.019 | 600.5 | 934.7 | 25,100 | 26,800 | 0.1304 |
| TBA | EGRET/ACSS/AW | 636.0 | 30/19 | 0.4995 | 0.6135 | 2 | 0.1456 | 0.0874 | 0.4370 | 1.019 | 600.5 | 928.2 | 26,300 | 28,000 | 0.1306 |
| TBA | GOOSE/ACSS/AW | 636.0 | 54/7 | 0.4993 | 0.5640 | 3 | 0.1085 | 0.1085 | 0.3255 | 0.977 | 598.8 | 784.4 | 16,700 | 17,300 | 0.1344 |
| TBA | FLAMINGO/ACSS/AW | 666.6 | 24/7 | 0.5238 | 0.5917 | 2 | 0.1667 | 0.1111 | 0.3333 | 1.000 | 628.2 | 823.0 | 17,500 | 18,200 | 0.1281 |
| TBA | GANNET/ACSS/AW | 666.6 | 26/7 | 0.5234 | 0.6086 | 2 | 0.1601 | 0.1245 | 0.3735 | 1.014 | 627.7 | 872.1 | 20,900 | 21,300 | 0.1269 |
| TBA | GULL/ACSS/AW | 666.6 | 54/7 | 0.5235 | 0.5914 | 3 | 0.1111 | 0.1111 | 0.3333 | 1.000 | 627.8 | 822.6 | 17,500 | 18,200 | 0.1282 |
| TBA | STILT/ACSS/AW | 715.5 | 24/7 | 0.5622 | 0.6350 | 2 | 0.1727 | 0.1151 | 0.3453 | 1.036 | 674.2 | 883.0 | 18,800 | 19,500 | 0.1194 |
| TBA | STARLING/ACSS/AW | 715.5 | 26/7 | 0.5620 | 0.6535 | 2 | 0.1659 | 0.1290 | 0.3870 | 1.051 | 674.0 | 936.5 | 22,000 | 22,900 | 0.1182 |
| TBA | REDWING/ACSS/AW | 715.5 | 30/19 | 0.5617 | 0.6897 | 2 | 0.1544 | 0.0926 | 0.4630 | 1.081 | 675.3 | 1043 | 29,500 | 30,800 | 0.1162 |
| TBA | CROW/ACSS/AW | 715.5 | 54/7 | 0.5619 | 0.6347 | 3 | 0.1151 | 0.1151 | 0.3453 | 1.036 | 673.9 | 882.7 | 18,800 | 19,500 | 0.1194 |
| TBA | TURBIT/ACSS/AW | 795.0 | 20/7 | 0.6246 | 0.6678 | 2 | 0.1994 | 0.0886 | 0.2658 | 1.063 | 749.1 | 873.0 | 13,500 | 14,200 | 0.1095 |
| TBA | PUFFIN/ACSS/AW | 795.0 | 22/7 | 0.6244 | 0.6857 | 2 | 0.1901 | 0.1056 | 0.3168 | 1.077 | 748.8 | 924.6 | 17,100 | 17,700 | 0.1086 |
| TBA | CUCKOO/ACSS/AW | 795.0 | 24/7 | 0.6244 | 0.7053 | 2 | 0.1820 | 0.1213 | 0.3639 | 1.092 | 748.8 | 980.9 | 20,900 | 21,300 | 0.1075 |
| TBA | DRAKE/ACSS/AW | 795.0 | 26/7 | 0.6247 | 0.7264 | 2 | 0.1749 | 0.1360 | 0.4080 | 1.108 | 749.2 | 1041 | 24,400 | 25,400 | 0.1063 |
| TBA | SKIMMER/ACSS/AW | 795.0 | 30/7 | 0.6245 | 0.7702 | 2 | 0.1628 | 0.1628 | 0.4884 | 1.140 | 750.8 | 1169 | 29,900 | 33,500 | 0.1043 |
| TBA | MALLARD/ACSS/AW | 795.0 | 30/19 | 0.6245 | 0.7669 | 2 | 0.1628 | 0.0977 | 0.4885 | 1.140 | 750.8 | 1160 | 32,900 | 34,300 | 0.1045 |
| TBA | TERN/ACSS/AW | 795.0 | 45/7 | 0.6242 | 0.6674 | 3 | 0.1329 | 0.0886 | 0.2658 | 1.063 | 748.6 | 872.5 | 13,500 | 14,200 | 0.1096 |
| TBA | CONDOR/ACSS/AW | 795.0 | 54/7 | 0.6240 | 0.7049 | 3 | 0.1213 | 0.1213 | 0.3639 | 1.092 | 748.3 | 980.4 | 20,900 | 21,300 | 0.1075 |
| TBA | RUDDY/ACSS/AW | 900.0 | 45/7 | 0.7066 | 0.7555 | 3 | 0.1414 | 0.0943 | 0.2829 | 1.131 | 847.4 | 987.7 | 15,300 | 15,800 | 0.0968 |
| TBA | CANARY/ACSS/AW | 900.0 | 54/7 | 0.7069 | 0.7985 | 3 | 0.1291 | 0.1291 | 0.3873 | 1.162 | 847.7 | 1111 | 23,200 | 24,100 | 0.0949 |
| TBA | CORNCRAKE/ACSS/AW | 954.0 | 20/7 | 0.7492 | 0.8010 | 2 | 0.2184 | 0.0971 | 0.2913 | 1.165 | 898.5 | 1047 | 16,200 | 16,700 | 0.0913 |
| TBA | REDBIRD/ACSS/AW | 954.0 | 24/7 | 0.7495 | 0.8466 | 2 | 0.1994 | 0.1329 | 0.3987 | 1.196 | 898.8 | 1177 | 24,600 | 25,500 | 0.0895 |
| TBA | MERGANSER/ACSS/AW | 954.0 | 30/7 | 0.7491 | 0.9239 | 2 | 0.1783 | 0.1783 | 0.5349 | 1.248 | 900.5 | 1402 | 35,000 | 40,200 | 0.0869 |
| TBA | CANVASBACK/ACSS/AW | 954.0 | 30/19 | 0.7491 | 0.9199 | 2 | 0.1783 | 0.1070 | 0.5350 | 1.248 | 900.5 | 1391 | 39,400 | 41,100 | 0.0871 |
| TBA | PHOENIX/ACSS/AW | 954.0 | 42/7 | 0.7491 | 0.7876 | 3 | 0.1507 | 0.0837 | 0.2511 | 1.155 | 898.4 | 1009 | 13,600 | 14,200 | 0.0919 |
| TBA | RAIL/ACSS/AW | 954.0 | 45/7 | 0.7492 | 0.8010 | 3 | 0.1456 | 0.0971 | 0.2913 | 1.165 | 898.5 | 1047 | 16,200 | 16,700 | 0.0913 |
| TBA | TOWHEE/ACSS/AW | 954.0 | 48/7 | 0.7495 | 0.8157 | 3 | 0.1410 | 0.1097 | 0.3291 | 1.175 | 898.8 | 1089 | 19,000 | 19,700 | 0.0907 |
| TBA | CARDINAL/ACSS/AW | 954.0 | 54/7 | 0.7491 | 0.8462 | 3 | 0.1329 | 0.1329 | 0.3987 | 1.196 | 898.4 | 1177 | 24,600 | 25,500 | 0.0896 |
| TBA | SNOWBIRD/ACSS/AW | 1033.5 | 42/7 | 0.8121 | 0.8539 | 3 | 0.1569 | 0.0872 | 0.2616 | 1.203 | 973.9 | 1094 | 14,800 | 15,400 | 0.0847 |
| TBA | ORTOLAN/ACSS/AW | 1033.5 | 45/7 | 0.8112 | 0.8673 | 3 | 0.1515 | 0.1010 | 0.3030 | 1.212 | 972.8 | 1134 | 17,600 | 18,100 | 0.0843 |
| TBA | WHOOPER/ACSS/AW | 1033.5 | 48/7 | 0.8113 | 0.8829 | 3 | 0.1467 | 0.1141 | 0.3423 | 1.223 | 973.0 | 1178 | 20,600 | 21,300 | 0.0838 |
| TBA | CURLEW/ACSS/AW | 1033.5 | 54/7 | 0.8112 | 0.9164 | 3 | 0.1383 | 0.1383 | 0.4149 | 1.245 | 972.8 | 1275 | 26,100 | 27,700 | 0.0827 |
| TBA | AVOCET/ACSS/AW | 1113.0 | 42/7 | 0.8743 | 0.9192 | 3 | 0.1628 | 0.0904 | 0.2712 | 1.248 | 1049 | 1178 | 15,900 | 16,300 | 0.0787 |
| TBA | BLUEJAY/ACSS/AW | 1113.0 | 45/7 | 0.8745 | 0.9350 | 3 | 0.1573 | 0.1049 | 0.3147 | 1.259 | 1049 | 1223 | 18,900 | 19,500 | 0.0782 |
| TBA | BULLFINCH/ACSS/AW | 1113.0 | 48/7 | 0.8744 | 0.9516 | 3 | 0.1523 | 0.1185 | 0.3555 | 1.269 | 1049 | 1271 | 22,200 | 23,000 | 0.0778 |
| TBA | FINCH/ACSS/AW | 1113.0 | 54/19 | 0.8746 | 0.9855 | 3 | 0.1436 | 0.0862 | 0.4310 | 1.293 | 1054 | 1373 | 28,800 | 30,400 | 0.0772 |
| TBA | OXBIRD/ACSS/AW | 1192.5 | 42/7 | 0.9366 | 0.9848 | 3 | 0.1685 | 0.0936 | 0.2808 | 1.292 | 1123 | 1261 | 17,000 | 17,500 | 0.0735 |
| TBA | BUNTING/ACSS/AW | 1192.5 | 45/7 | 0.9367 | 1.0014 | 3 | 0.1628 | 0.1085 | 0.3255 | 1.302 | 1123 | 1309 | 20,300 | 20,900 | 0.0730 |
| TBA | CORMORANT/ACSS/AW | 1192.5 | 48/7 | 0.9364 | 1.0190 | 3 | 0.1576 | 0.1226 | 0.3678 | 1.313 | 1123 | 1360 | 23,800 | 24,200 | 0.0726 |
| TBA | GRACKLE/ACSS/AW | 1192.5 | 54/19 | 0.9365 | 1.0552 | 3 | 0.1486 | 0.0892 | 0.4460 | 1.338 | 1129 | 1470 | 30,800 | 32,600 | 0.0721 |
| TBA | SCISSORTAIL/ACSS/AW | 1272.0 | 42/7 | 0.9987 | 1.0501 | 3 | 0.1740 | 0.0967 | 0.2901 | 1.334 | 1198 | 1345 | 18,200 | 18,700 | 0.0689 |
| TBA | BITTERN/ACSS/AW | 1272.0 | 45/7 | 0.9987 | 1.0678 | 3 | 0.1681 | 0.1121 | 0.3363 | 1.345 | 1198 | 1396 | 21,600 | 22,300 | 0.0685 |
| TBA | DIVER/ACSS/AW | 1272.0 | 48/7 | 0.9992 | 1.0873 | 3 | 0.1628 | 0.1266 | 0.3798 | 1.357 | 1198 | 1451 | 25,300 | 25,800 | 0.0681 |
| TBA | PHEASANT/ACSS/AW | 1272.0 | 54/19 | 0.9993 | 1.1259 | 3 | 0.1535 | 0.0921 | 0.4605 | 1.382 | 1204 | 1568 | 32,800 | 34,100 | 0.0675 |
| TBA | RINGDOVE/ACSS/AW | 1351.5 | 42/7 | 1.0617 | 1.1163 | 3 | 0.1794 | 0.0997 | 0.2991 | 1.376 | 1273 | 1430 | 19,300 | 19,900 | 0.0648 |
| TBA | DIPPER/ACSS/AW | 1351.5 | 45/7 | 1.0614 | 1.1347 | 3 | 0.1733 | 0.1155 | 0.3465 | 1.386 | 1273 | 1483 | 23,000 | 23,700 | 0.0645 |
| TBA | MARTIN/ACSS/AW | 1351.5 | 54/19 | 1.0614 | 1.1958 | 3 | 0.1582 | 0.0949 | 0.4745 | 1.424 | 1279 | 1665 | 34,900 | 36,200 | 0.0636 |
| TBA | POPINJAY/ACSS/AW | 1431.0 | 42/7 | 1.1241 | 1.1820 | 3 | 0.1846 | 0.1026 | 0.3078 | 1.415 | 1348 | 1514 | 20,500 | 21,000 | 0.0612 |
| TBA | BOBOLINK/ACSS/AW | 1431.0 | 45/7 | 1.1236 | 1.2013 | 3 | 0.1783 | 0.1189 | 0.3567 | 1.427 | 1347 | 1570 | 24,300 | 25,100 | 0.0609 |
| TBA | WAGTAIL/ACSS/AW | 1431.0 | 48/7 | 1.1244 | 1.2236 | 3 | 0.1727 | 0.1343 | 0.4029 | 1.439 | 1348 | 1633 | 28,000 | 29,000 | 0.0605 |
| TBA | PLOVER/ACSS/AW | 1431.0 | 54/19 | 1.1241 | 1.2665 | 3 | 0.1628 | 0.0977 | 0.4885 | 1.465 | 1355 | 1764 | 36,900 | 38,400 | 0.0600 |
| TBA | NUTHATCH/ACSS/AW | 1510.5 | 45/7 | 1.1862 | 1.2682 | 3 | 0.1832 | 0.1221 | 0.3663 | 1.466 | 1423 | 1658 | 25,700 | 26,100 | 0.0577 |
| TBA | PARROT/ACSS/AW | 1510.5 | 54/19 | 1.1856 | 1.3357 | 3 | 0.1672 | 0.1003 | 0.5015 | 1.505 | 1429 | 1860 | 38,900 | 40,400 | 0.0569 |
| TBA | RATITE/ACSS/AW | 1590.0 | 42/7 | 1.2492 | 1.3134 | 3 | 0.1946 | 0.1081 | 0.3243 | 1.492 | 1498 | 1682 | 22,700 | 23,400 | 0.0551 |
| TBA | LAPWING/ACSS/AW | 1590.0 | 45/7 | 1.2492 | 1.3355 | 3 | 0.1880 | 0.1253 | 0.3759 | 1.504 | 1498 | 1746 | 27,000 | 27,500 | 0.0548 |
| TBA | HORNBILL/ACSS/AW | 1590.0 | 48/7 | 1.2487 | 1.3589 | 3 | 0.1820 | 0.1416 | 0.4248 | 1.517 | 1498 | 1814 | 30,600 | 31,700 | 0.0545 |
| TBA | FALCON/ACSS/AW | 1590.0 | 54/19 | 1.2489 | 1.4072 | 3 | 0.1716 | 0.1030 | 0.5150 | 1.545 | 1505 | 1960 | 41,100 | 42,600 | 0.0540 |
| TBA | CHUKAR/ACSS/AW | 1780.0 | 84/19 | 1.3986 | 1.5126 | 4 | 0.1456 | 0.0874 | 0.4370 | 1.602 | 1685 | 2013 | 33,600 | 35,400 | 0.0490 |
| TBA | WOODPECKER/ACSS/AW | 1843.0 | 72/7 | 1.4476 | 1.5102 | 4 | 0.1600 | 0.1067 | 0.3201 | 1.600 | 1745 | 1925 | 24,000 | 24,600 | 0.0479 |
| TBA | SEAHAWK/ACSS/AW | 1869.0 | 68/7 | 1.4681 | 1.5147 | 4 | 0.1658 | 0.0921 | 0.2763 | 1.603 | 1769 | 1903 | 21,100 | 21,500 | 0.0474 |
| TBA | MOCKINGBIRD/ACSS/AW | 2034.5 | 72/7 | 1.5979 | 1.6670 | 4 | 0.1681 | 0.1121 | 0.3363 | 1.681 | 1926 | 2124 | 26,500 | 27,200 | 0.0434 |
| TBA | BLUEBIRD/ACSS/AW | 2156.0 | 84/19 | 1.6931 | 1.8309 | 4 | 0.1602 | 0.0961 | 0.4805 | 1.762 | 2040 | 2436 | 40,700 | 42,100 | 0.0404 |
| TBA | KIWI/ACSS/AW | 2167.0 | 72/7 | 1.7022 | 1.7758 | 4 | 0.1735 | 0.1157 | 0.3471 | 1.735 | 2051 | 2262 | 28,200 | 29,000 | 0.0407 |
| TBA | THRASHER/ACSS/AW | 2312.0 | 76/19 | 1.8155 | 1.9144 | 4 | 0.1744 | 0.0814 | 0.4070 | 1.802 | 2188 | 2472 | 34,100 | 35,600 | 0.0380 |
| TBA | JOREE/ACSS/AW | 2515.0 | 76/19 | 1.9750 | 2.0826 | 4 | 0.1819 | 0.0849 | 0.4245 | 1.880 | 2380 | 2689 | 37,100 | 38,700 | 0.0350 |
Revision: 1.000.003
Updated On: Nov. 20, 2026, 11:22 p.m. UTC