SPEC 70078

600V SEOPRENE PLUS® SEOOW Cord with Yellow Jacket 105°C. Silicone-Free

600 Volt, 105°C Flexible Cord. Premium Oil Resistance, Sunlight, Water Resistance and Flame Retardant, UL / CSA listed.

...

Construction:

  1. Conductor:Class K stranded bare copper per ASTM B-174
  2. Insulation:Heat, moisture and oil resistant TPE
  3. Filler:Non-wicking polypropylene fillers, with a tissue-paper separator wrapped around the assembly
  4. Jacket:Yellow TPE (other colors available upon request)

Applications and Features:

Southwire Type SEOOW Flexible Cords are permitted for indoor and outdoor temporary power uses, portable industrial machinery and compressors, food processing and washdown facilities. Type SEOOW Cords are suitable for use in temperatures between -40°C to maximum 105°C.

Specifications:

  • UL 62 Flexible Cords and Cables
  • CSA C22.2 No. 49 Flexible Cords and Cables
  • Passes CSA FT2 Flame Test
  • RoHS-3 Complies with European Directive 2015/863
  • NEC Article 400 Flexible Cords, Cables and Fixture Wire
  • NEC Article 501.140 Class I Division 2
  • Sample Print Legend:

    SOUTHWIRE® SEOPRENE PLUS{TM} CORD X/C XX AWG (X.XX{mm2}) SEOOW E46194 {UL} 600V -40°C TO 105°C -- CSA LL90458 SEOOW 600V -50°C TO 105°C FT2 WATER RESISTANT

    Packaging:

    Standard lengths: 250', 500' and 1,000' reels. Other lengths available upon request.
    Table 1 – Weights and Measurements
    Stock NumberCond. SizeCond. NumberCond. StrandsInsul. ThicknessJacket ThicknessApprox. ODApprox. WeightAmpacityInsul. ColorJacket Color
    AWG/KcmilNo.No.milmilinchlb/1000ftAmp
    6556621831630600.363637BK/WE/GNYellow
    5983351841630600.387755BK/WE/RD/GYellow
    6556881622630600.3676113BK/WEYellow
    6556961632630600.3877710BK/WE/GNYellow
    6557041642630600.416938BK/WE/GN/RYellow
    6722721652630850.5031318BK/WE/RD/GYellow
    5983361424145800.49711118BK/WEYellow
    6557201434145800.52213515BK/WE/GNYellow
    6557381444145800.56516412BK/WE/RD/GYellow
    6557461226545950.57014925WE/BKYellow
    6557531236545950.59218520BK/WE/GNYellow
    6557611246545950.64222916BK/WE/RD/GYellow
    655787103104451050.65224425BK/WE/GNYellow
    655795104104451000.70330120BK/WE/RD/GYellow
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item
    * Ampacities are based on TABLE 400.5(A)(1) of the 2023 National Electrical Code and CEC Table 12.
    Table 2 – Weights and Measurements (Metric)
    Stock NumberCond. SizeCond. NumberCond. StrandsInsul. ThicknessJacket ThicknessApprox. ODApprox. WeightAmpacity *Insul. ColorJacket Color
    AWG/KcmilNo.No.mmmmmmkg/kmAmp
    655662183160.761.529.22947BK/WE/GNYellow
    598335184160.761.529.831125BK/WE/RD/GYellow
    655688162260.761.529.329113BK/WEYellow
    655696163260.761.529.8311510BK/WE/GNYellow
    655704164260.761.5210.571388BK/WE/GN/RYellow
    672272165260.762.1612.781958BK/WE/RD/GYellow
    598336142411.142.0312.6216518BK/WEYellow
    655720143411.142.0313.2620115BK/WE/GNYellow
    655738144411.142.0314.3524412BK/WE/RD/GYellow
    655746122651.142.4114.4822225WE/BKYellow
    655753123651.142.4115.0427520BK/WE/GNYellow
    655761124651.142.4116.3134116BK/WE/RD/GYellow
    6557871031041.142.6716.5636325BK/WE/GNYellow
    6557951041041.142.5417.8644820BK/WE/RD/GYellow
    * Ampacities are based on TABLE 400.5(A)(1) of the 2023 National Electrical Code and CEC Table 12.

    Color Code

    # of ConductorColor Sequence
    2Black, White
    3Black, White, Green
    4Black, White, Red, Green

    Revision: 1.000.000

    Updated On: July 3, 2024, 9:53 p.m. UTC