SPEC 70078

600V SEOPRENE PLUS® SEOOW Cord with Yellow Jacket 105°C. Silicone-Free

600 Volt, 105°C Flexible Cord. Premium Oil Resistance, Sunlight, Water Resistance and Flame Retardant, UL / CSA listed.

...

Construction:

  1. Conductor:Class K stranded bare copper per ASTM B-174
  2. Insulation:Heat, moisture and oil resistant TPE
  3. Filler:Non-wicking polypropylene fillers, with a tissue-paper separator wrapped around the assembly
  4. Jacket:Yellow TPE (other colors available upon request)

Applications and Features:

Southwire Type SEOOW Flexible Cords are permitted for indoor and outdoor temporary power uses, portable industrial machinery and compressors, food processing and washdown facilities. Type SEOOW Cords are suitable for use in temperatures between -40°C to maximum 105°C.

Specifications:

  • UL 62 Flexible Cords and Cables
  • CSA C22.2 No. 49 Flexible Cords and Cables
  • Passes CSA FT2 Flame Test
  • RoHS-3 Complies with European Directive 2015/863
  • NEC Article 400 Flexible Cords, Cables and Fixture Wire
  • NEC Article 501.140 Class I Division 2
  • Sample Print Legend:

    SOUTHWIRE® SEOPRENE PLUS{TM} CORD X/C XX AWG (X.XX{mm2}) SEOOW E46194 {UL} 600V -40°C TO 105°C -- CSA LL90458 SEOOW 600V -50°C TO 105°C FT2 WATER RESISTANT

    Packaging:

    Standard lengths: 250', 500' and 1,000' reels. Other lengths available upon request.
    Table 1 – Weights and Measurements
    Stock NumberCond. SizeCond. NumberCond. StrandsInsul. ThicknessJacket ThicknessApprox. ODApprox. WeightAmpacityInsul. ColorJacket Color
    AWG/KcmilNo.No.milmilinchlb/1000ftAmp
    6556621831630600.363637BK,WE,GNYW
    6556881622630600.3676113BK,WEYW
    6556961632630600.3877710BK,WE,GNYW
    6557041642630600.416938BK,WE,GN,RDYW
    6722721652630850.5031318BK,WE,RD,GN,OEYW
    5983361424145800.49711118BK,WEYW
    6557201434145800.52213515BK,WE,GNYW
    6557381444145800.56516412BK,WE,RD,GNYW
    6557531236545950.59218520BK,WE,GNYW
    6557611246545950.64222916BK,WE,RD,GNYW
    655787103104451050.65224425BK,WE,GNYW
    655795104104451000.70330120BK,WE,RD,GNYW
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item
    * Ampacities are based on TABLE 400.5(A)(1) of the 2023 National Electrical Code and CEC Table 12.
    TBA stock codes are estimations only and actual product may vary. Please wait until a stock code is assigned to purchase connectors and/or fittings.
    Table 2 – Weights and Measurements (Metric)
    Stock NumberCond. SizeCond. NumberCond. StrandsInsul. ThicknessJacket ThicknessApprox. ODApprox. WeightAmpacity *Insul. ColorJacket Color
    AWG/KcmilNo.No.mmmmmmkg/kmAmp
    655662183160.761.529.22947BK,WE,GNYW
    655688162260.761.529.329113BK,WEYW
    655696163260.761.529.8311510BK,WE,GNYW
    655704164260.761.5210.571388BK,WE,GN,RDYW
    672272165260.762.1612.781958BK,WE,RD,GN,OEYW
    598336142411.142.0312.6216518BK,WEYW
    655720143411.142.0313.2620115BK,WE,GNYW
    655738144411.142.0314.3524412BK,WE,RD,GNYW
    655753123651.142.4115.0427520BK,WE,GNYW
    655761124651.142.4116.3134116BK,WE,RD,GNYW
    6557871031041.142.6716.5636325BK,WE,GNYW
    6557951041041.142.5417.8644820BK,WE,RD,GNYW
    * Ampacities are based on TABLE 400.5(A)(1) of the 2023 National Electrical Code and CEC Table 12.

    Revision: 1.000.001

    Updated On: March 31, 2025, 12:33 a.m. UTC