SPEC 70002
600V ROYAL® SOOW Power Cord Non-UL/CSA with Black Jacket 90°C. MSHA Approved
600 Volt, 90°C Flexible Cord. Heat, Moisture and Oil Resistant EPDM Rubber Insulation and Heat, Moisture and Oil Resistant Flexible CPE Jacket, Non-UL / Non-CSA.

Construction:
- Conductor:Class K flexible stranded bare copper per ASTM B3 and B174
- Insulation:Heat, moisture, and oil resistant EPDM
- Filler:Waxed paper fillers
- Jacket:Black Chlorinated Polyethylene (CPE) (other colors available upon request)
Applications and Features:
Southwire Royal® Non-UL/Non-CSA SOOW cord is designed for use with industrial equipment, heavy tools, battery chargers, portable lights and power extensions, suitable for outdoor applications. The cable is rated -40°C to 90°C, sunlight, water, oil, and weather resistant. Southwire Type SOOW Flexible Cords are permitted for use as specified by Article 400 and related articles of the 2023 National Electrical Code.
Specifications:
Sample Print Legend:
SOUTHWIRE® ROYAL® CORD X/C X AWG (X.XXmm2) SOOW 600V -40C TO 90C
Packaging:
Standard lengths: 250', 500' and 1,000' reels. Other lengths available upon request.
Table 1 – Weights and Measurements
| Stock Number | Cond. Size | Cond. Number | Cond. Strands | Insul. Thickness | Jacket Thickness | Approx. OD | Approx. Weight | Ampacity | DC Resistance | Insul. Color | Jacket Color |
|---|---|---|---|---|---|---|---|---|---|---|---|
| AWG/Kcmil | No. | No. | mil | mil | inch | lb/1000ft | Amp | Ω/1000ft | |||
| 569972 | 8 | 2 | 133 | 45 | 75 | 0.615 | 218 | 40 | 0.708 | BK,WE | BK |
| 558088 | 8 | 3 | 133 | 45 | 75 | 0.645 | 290 | 35 | 0.708 | BK,WE,GN | BK |
| 558093 | 8 | 4 | 133 | 45 | 75 | 0.715 | 376 | 28 | 0.708 | BK,WE,RD,GN | BK |
| 558105 | 8 | 5 | 133 | 45 | 105 | 0.834 | 492 | 28 | 0.708 | BK,WE,RD,GN,OE | BK |
| 569973 | 6 | 2 | 133 | 45 | 100 | 0.721 | 337 | 55 | 0.446 | BK,WE | BK |
| 558092 | 6 | 3 | 133 | 45 | 90 | 0.726 | 419 | 45 | 0.446 | BK,WE,GN | BK |
| 558091 | 6 | 4 | 133 | 45 | 85 | 0.803 | 539 | 36 | 0.446 | BK,WE,RD,GN | BK |
| 558161 | 6 | 5 | 133 | 45 | 110 | 0.937 | 702 | 36 | 0.446 | BK,WE,RD,GN,OE | BK |
| 558137 | 4 | 3 | 133 | 45 | 95 | 0.825 | 590 | 60 | 0.279 | BK,WE,GN | BK |
| 558090 | 4 | 4 | 133 | 45 | 100 | 0.95 | 762 | 48 | 0.279 | BK,WE,RD,GN | BK |
| 558136 | 2 | 3 | 168 | 45 | 115 | 1.09 | 992 | 80 | 0.166 | BK,WE,GN | BK |
| 558089 | 2 | 4 | 168 | 45 | 130 | 1.29 | 1314 | 64 | 0.166 | BK,WE,RD,GN | BK |
| 569976 | 2 | 5 | 168 | 45 | 120 | 1.373 | 1654 | 64 | 0.166 | BK,WE,RD,GN,OE | BK |
All dimensions are nominal and subject to normal manufacturing tolerances
◊ Cable marked with this symbol is a standard stock item
* Ampacities are based on TABLE 400.5(A)(1) of the 2023 National Electrical Code and CEC Table 12.
TBA stock codes are estimations only and actual product may vary. Please wait until a stock code is assigned to purchase connectors and/or fittings.
TBA stock codes are estimations only and actual product may vary. Please wait until a stock code is assigned to purchase connectors and/or fittings.
Table 2 – Weights and Measurements (Metric)
| Stock Number | Cond. Size | Cond. Number | Cond. Strands | Insul. Thickness | Jacket Thickness | Approx. OD | Approx. Weight | Ampacity * | DC Resistance | Insul. Color | Jacket Color |
|---|---|---|---|---|---|---|---|---|---|---|---|
| AWG/Kcmil | No. | No. | mm | mm | mm | kg/km | Amp | Ω/km | |||
| 569972 | 8 | 2 | 133 | 1.14 | 1.91 | 15.62 | 324 | 40 | 2.32 | BK,WE | BK |
| 558088 | 8 | 3 | 133 | 1.14 | 1.91 | 16.38 | 432 | 35 | 2.32 | BK,WE,GN | BK |
| 558093 | 8 | 4 | 133 | 1.14 | 1.91 | 18.16 | 560 | 28 | 2.32 | BK,WE,RD,GN | BK |
| 558105 | 8 | 5 | 133 | 1.14 | 2.67 | 21.18 | 732 | 28 | 2.32 | BK,WE,RD,GN,OE | BK |
| 569973 | 6 | 2 | 133 | 1.14 | 2.54 | 18.31 | 502 | 55 | 1.46 | BK,WE | BK |
| 558092 | 6 | 3 | 133 | 1.14 | 2.29 | 18.44 | 624 | 45 | 1.46 | BK,WE,GN | BK |
| 558091 | 6 | 4 | 133 | 1.14 | 2.16 | 20.40 | 802 | 36 | 1.46 | BK,WE,RD,GN | BK |
| 558161 | 6 | 5 | 133 | 1.14 | 2.79 | 23.80 | 1045 | 36 | 1.46 | BK,WE,RD,GN,OE | BK |
| 558137 | 4 | 3 | 133 | 1.14 | 2.41 | 20.96 | 878 | 60 | 0.92 | BK,WE,GN | BK |
| 558090 | 4 | 4 | 133 | 1.14 | 2.54 | 24.13 | 1134 | 48 | 0.92 | BK,WE,RD,GN | BK |
| 558136 | 2 | 3 | 168 | 1.14 | 2.92 | 27.69 | 1476 | 80 | 0.54 | BK,WE,GN | BK |
| 558089 | 2 | 4 | 168 | 1.14 | 3.30 | 32.77 | 1955 | 64 | 0.54 | BK,WE,RD,GN | BK |
| 569976 | 2 | 5 | 168 | 1.14 | 3.05 | 34.87 | 2461 | 64 | 0.54 | BK,WE,RD,GN,OE | BK |
* Ampacities are based on TABLE 400.5(A)(1) of the 2023 National Electrical Code and CEC Table 12.