SPEC 26406
HVTECK CU 1/C 320NLEPR CB PVC AIA PVC 25kV 133% CSA
Single Conductor, 320 Mils No Lead Ethylene Propylene Rubber (NL-EPR), 133% Insulation Level, Concentric Bond, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket

Construction:
- Conductor:Class B compressed stranded bare copper per ASTM B3 and ASTM B8
- Conductor Shield:Semi-conducting cross-linked copolymer
- Insulation:320 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% insulation level
- Insulation Shield:Strippable semi-conducting cross-linked copolymer
- Concentric Shield:Concentrically applied copper bond / shield wires. Complies with greater than the minimum requirement as per Table 44, CSA Standard C68.10 and Table 16A, Canadian Electrical Code Part 1
- Neutral Separator:Mylar tape
- Inner Jacket:PVC inner jacket
- Armour:Aluminum Interlocked Armour (AIA)
- Overall Jacket:Black Polyvinyl Chloride (PVC) Jacket
Applications and Features:
Southwire's 25kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs /FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant.
Specifications:
Sample Print Legend:
(CSA) SOUTHWIRE (NESC) #P# 1/C [#AWG or #kcmil] CU 320 NLEPR AIA 25kV 133% INS LEVEL CB [No. x SIZE] AWG SUN RES 105°C FT4 HL (-40°C) LTGG RoHS YEAR [SEQUENTIAL METER MARKS]
Table 1 – Weights and Measurements
Cond. Size | Strand | Diameter Over Conductor | Diameter Over Insulation | Insul. Thickness | Diameter Over Insulation Shield | Concentric Neutral | Inner Jacket Thickness | Dia. Over Armour | Overall Jacket Thickness | Approx. OD | Approx. Weight |
---|---|---|---|---|---|---|---|---|---|---|---|
AWG/Kcmil | No. | inch | inch | mil | inch | No. x AWG | mil | inch | mil | inch | lb/1000ft |
1 | 19 | 0.322 | 1.000 | 320 | 1.060 | 11 x 14 | 80 | 1.710 | 60 | 1.830 | 1487 |
1/0 | 19 | 0.361 | 1.039 | 320 | 1.099 | 11 x 14 | 80 | 1.749 | 60 | 1.869 | 1595 |
2/0 | 19 | 0.405 | 1.083 | 320 | 1.143 | 11 x 14 | 80 | 1.793 | 60 | 1.913 | 1726 |
3/0 | 19 | 0.456 | 1.134 | 320 | 1.194 | 13 x 14 | 80 | 1.844 | 60 | 1.964 | 1917 |
4/0 | 19 | 0.512 | 1.190 | 320 | 1.250 | 13 x 14 | 80 | 1.900 | 60 | 2.020 | 2204 |
250 | 37 | 0.558 | 1.244 | 320 | 1.304 | 17 x 14 | 80 | 1.954 | 60 | 2.074 | 2440 |
350 | 37 | 0.661 | 1.347 | 320 | 1.407 | 21 x 14 | 110 | 2.117 | 60 | 2.237 | 3042 |
500 | 37 | 0.789 | 1.475 | 320 | 1.535 | 26 x 14 | 110 | 2.245 | 60 | 2.365 | 3725 |
750 | 61 | 0.968 | 1.664 | 320 | 1.724 | 21 x 12 | 110 | 2.468 | 75 | 2.618 | 4911 |
1000 | 61 | 1.117 | 1.813 | 320 | 1.873 | 21 x 12 | 110 | 2.617 | 75 | 2.767 | 5865 |
All dimensions are nominal and subject to normal manufacturing tolerances
◊ Cable marked with this symbol is a standard stock item
1 Comply with ICEA S-93-639 Appendix C for jacket thickness determination
Table 2 – Electrical and Engineering Data
Cond. Size | Min Bending Radius | Max Pull Tension | DC Resistance @ 25°C | AC Resistance @ 90°C | Capacitive Reactance @ 60Hz | Inductive Reactance @ 60Hz | Zero Sequence Impedance* | Positive Sequence Impedance* | Phase Short Circuit Current @ 60Hz | Allowable Ampacity In Air 90°C | Allowable Ampacity Directly Buried 90°C |
---|---|---|---|---|---|---|---|---|---|---|---|
AWG/Kcmil | inch | lb | Ω/1000ft | Ω/1000ft | MΩ/1000ft | Ω/1000ft | Ω/1000ft | Ω/1000ft | kAmp | Amp | Amp |
1 | 12.8 | 669 | 0.128 | 0.162 | 0.059 | 0.062 | 0.144 + j0.037 | 0.15 + j0.045 | 8577 | 245 | 244 |
1/0 | 13.0 | 844 | 0.102 | 0.128 | 0.055 | 0.059 | 0.11 + j0.035 | 0.116 + j0.043 | 8577 | 278 | 272 |
2/0 | 13.3 | 1064 | 0.081 | 0.102 | 0.051 | 0.057 | 0.084 + j0.033 | 0.09 + j0.041 | 8577 | 316 | 303 |
3/0 | 13.7 | 1342 | 0.064 | 0.081 | 0.047 | 0.055 | 0.063 + j0.031 | 0.069 + j0.039 | 10137 | 356 | 333 |
4/0 | 14.1 | 1692 | 0.051 | 0.065 | 0.044 | 0.053 | 0.047 + j0.029 | 0.053 + j0.038 | 10137 | 403 | 367 |
250 | 14.5 | 2000 | 0.043 | 0.056 | 0.041 | 0.052 | 0.038 + j0.028 | 0.044 + j0.036 | 13256 | 455 | 411 |
350 | 15.6 | 2800 | 0.031 | 0.041 | 0.037 | 0.050 | 0.023 + j0.026 | 0.029 + j0.034 | 16376 | 537 | 459 |
500 | 16.5 | 4000 | 0.022 | 0.030 | 0.032 | 0.047 | 0.012 + j0.024 | 0.018 + j0.032 | 20275 | 616 | 499 |
750 | 18.3 | 6000 | 0.014 | 0.023 | 0.028 | 0.045 | 0.005 + j0.022 | 0.012 + j0.03 | 26018 | 716 | 557 |
1000 | 19.3 | 8000 | 0.011 | 0.019 | 0.025 | 0.043 | 0.001 + j0.02 | 0.008 + j0.028 | 26018 | 825 | 608 |
* Inductive impedance is based on non-ferrous conduit with one diameter spacing.
Table 3 – Weights and Measurements (Metric)
Cond. Size | Strand | Diameter Over Conductor | Diameter Over Insulation | Insul. Thickness | Diameter Over Insulation Shield | Concentric Neutral | Inner Jacket Thickness | Dia. Over Armour | Overall Jacket Thickness | Approx. OD | Approx. Weight |
---|---|---|---|---|---|---|---|---|---|---|---|
AWG/Kcmil | No. | mm | mm | mm | mm | No. x AWG | mm | mm | mm | mm | kg/km |
1 | 19 | 8.18 | 25.40 | 8.13 | 26.92 | 11 x 14 | 2.03 | 43.43 | 1.52 | 46.48 | 2213 |
1/0 | 19 | 9.17 | 26.39 | 8.13 | 27.91 | 11 x 14 | 2.03 | 44.42 | 1.52 | 47.47 | 2374 |
2/0 | 19 | 10.29 | 27.51 | 8.13 | 29.03 | 11 x 14 | 2.03 | 45.54 | 1.52 | 48.59 | 2569 |
3/0 | 19 | 11.58 | 28.80 | 8.13 | 30.33 | 13 x 14 | 2.03 | 46.84 | 1.52 | 49.89 | 2853 |
4/0 | 19 | 13.00 | 30.23 | 8.13 | 31.75 | 13 x 14 | 2.03 | 48.26 | 1.52 | 51.31 | 3280 |
250 | 37 | 14.17 | 31.60 | 8.13 | 33.12 | 17 x 14 | 2.03 | 49.63 | 1.52 | 52.68 | 3631 |
350 | 37 | 16.79 | 34.21 | 8.13 | 35.74 | 21 x 14 | 2.79 | 53.77 | 1.52 | 56.82 | 4527 |
500 | 37 | 20.04 | 37.47 | 8.13 | 38.99 | 26 x 14 | 2.79 | 57.02 | 1.52 | 60.07 | 5543 |
750 | 61 | 24.59 | 42.27 | 8.13 | 43.79 | 21 x 12 | 2.79 | 62.69 | 1.91 | 66.50 | 7308 |
1000 | 61 | 28.37 | 46.05 | 8.13 | 47.57 | 21 x 12 | 2.79 | 66.47 | 1.91 | 70.28 | 8728 |
All dimensions are nominal and subject to normal manufacturing tolerances
◊ Cable marked with this symbol is a standard stock item
1 Comply with ICEA S-93-639 Appendix C for jacket thickness determination
Table 4 – Electrical and Engineering Data (Metric)
Cond. Size | Min Bending Radius | Max Pull Tension | DC Resistance @ 25°C | AC Resistance @ 90°C | Capacitive Reactance @ 60Hz | Inductive Reactance @ 60Hz | Zero Sequence Impedance* | Positive Sequence Impedance* | Phase Short Circuit Current @ 60Hz | Allowable Ampacity In Air 90°C | Allowable Ampacity Directly Buried 90°C |
---|---|---|---|---|---|---|---|---|---|---|---|
AWG/Kcmil | mm | newton | Ω/km | Ω/km | MΩ/km | Ω/km | Ω/1000ft | Ω/1000ft | kAmp | Amp | Amp |
1 | 325.12 | 2977 | 0.4199 | 0.53 | 0.0180 | 0.2034 | 0.144 + j0.037 | 0.15 + j0.045 | 8577 | 245 | 244 |
1/0 | 330.20 | 3756 | 0.3346 | 0.42 | 0.0168 | 0.1936 | 0.11 + j0.035 | 0.116 + j0.043 | 8577 | 278 | 272 |
2/0 | 337.82 | 4735 | 0.2657 | 0.33 | 0.0155 | 0.1870 | 0.084 + j0.033 | 0.09 + j0.041 | 8577 | 316 | 303 |
3/0 | 347.98 | 5972 | 0.2100 | 0.27 | 0.0143 | 0.1804 | 0.063 + j0.031 | 0.069 + j0.039 | 10137 | 356 | 333 |
4/0 | 358.14 | 7529 | 0.1673 | 0.21 | 0.0134 | 0.1739 | 0.047 + j0.029 | 0.053 + j0.038 | 10137 | 403 | 367 |
250 | 368.30 | 8900 | 0.1411 | 0.18 | 0.0125 | 0.1706 | 0.038 + j0.028 | 0.044 + j0.036 | 13256 | 455 | 411 |
350 | 396.24 | 12460 | 0.1017 | 0.13 | 0.0113 | 0.1640 | 0.023 + j0.026 | 0.029 + j0.034 | 16376 | 537 | 459 |
500 | 419.10 | 17800 | 0.0722 | 0.10 | 0.0098 | 0.1542 | 0.012 + j0.024 | 0.018 + j0.032 | 20275 | 616 | 499 |
750 | 464.82 | 26700 | 0.0459 | 0.08 | 0.0085 | 0.1476 | 0.005 + j0.022 | 0.012 + j0.03 | 26018 | 716 | 557 |
1000 | 490.22 | 35600 | 0.0361 | 0.06 | 0.0076 | 0.1411 | 0.001 + j0.02 | 0.008 + j0.028 | 26018 | 825 | 608 |
* Inductive impedance is based on non-ferrous conduit with one diameter spacing.
Revision: 1.000.000
Updated On: Aug. 18, 2023, 2:39 p.m. UTC