SPEC 70118

600V ROYAL® SOOW Cord Control with Black Jacket 90°C. MSHA Approved

600 Volt 90°C Flexible Cord. Heat, Moisture and Oil Resistant EPDM Rubber Insulation, Heat, Moisture and Oil Resistant Flexible CPE Jacket

...

Construction:

  1. Conductor:Class K stranded bare copper per ASTM B-174
  2. Insulation:Heat, moisture and oil resistant EPDM
  3. Filler:Waxed paper fillers, with a tissue-paper separator wrapped around the assembly
  4. Jacket:Black CPE (Other colors available upon request)

Applications and Features:

Southwire Type SOOW Flexible Cords UL/ CSA listed are permitted for use as specified by Article 400 and related articles of the 2014 National Electrical Code. The cable is rated -40°C to 90°C, water, oil, and weather resistant. Southwire Type SOOW Flexible Cords are designed for extra hard usage on industrial equipment, heavy tools, battery chargers, portable lights, welding leads, marine dockside power, power extensions and mining applications.

Specifications:

  • UL 62 Flexible Cords and Cables
  • CSA C22.2 No. 49 Flexible Cords and Cables
  • MSHA flame test - P07-KA070018-1MSHA
  • Passes CSA FT2 Flame Test
  • RoHS-3 Complies with European Directive 2015/863
  • NEC Article 400 Flexible Cords, Cables and Fixture Wire
  • NEC Article 501.140 Class I Division 2
  • Federal Specification J-C-580B
  • Sample Print Legend:

    SOUTHWIRE® ROYAL® CORD XX/C XX AWG ({mm2}) SOOW E46194 {UL} 600V -40°C TO 90°C -- {CSA} LL90458 SOOW 600V -40°C TO 90°C FT2 WATER RESISTANT {NOM}-ANCE -- {MSHA}

    Packaging:

    Standard lengths: 250', 500' and 1,000' reels. Other lengths available upon request.
    Table 1 – Weights and Measurements
    Stock NumberCCI Part #Cond. SizeCond. NumberCond. StrandsInsul. ThicknessJacket ThicknessApprox. ODApprox. WeightAmpacityInsul. ColorJacket Color
    AWG/KcmilNo.No.milmilinchlb/1000ftAmp
    5582368306051861630850.4881375See TableBK
    5582378307051871630800.4881384See TableBK
    5582388308051881630850.5211624See TableBK
    57003483100518101630900.5962003See TableBK
    57003783120518121630900.6172263See TableBK
    59830283140518141630900.6402533See TableBK
    570039831605181616301000.6682823See TableBK
    57004283200518201630950.7393303See TableBK
    570043832405182416301100.8304093See TableBK
    571692833005183016301000.8684563See TableBK
    5582328306061662630900.5161688See TableBK
    5582338307061672630900.5642017See TableBK
    5582348308061682630900.5662077See TableBK
    56052683100616102630900.6482715See TableBK
    560527831206161226301050.6963245See TableBK
    598305831406161426301100.7273375See TableBK
    57001883200616202630950.7453965See TableBK
    560528831606161626301100.7783735See TableBK
    570019832406162426301100.9195074See TableBK
    570026833006163026301300.9826474See TableBK
    55814983060714641451050.66432312See TableBK
    5581508307071474145950.71231210See TableBK
    55823083080714841451150.73034610See TableBK
    569994831007141041451100.7704047See TableBK
    571270831207141241451100.8834717See TableBK
    569995831407141441451300.9806027See TableBK
    569997831607141641451301.0166427See TableBK
    55814483060812665451100.74037916See TableBK
    5581458307081276545950.74035314See TableBK
    55814683080812865451100.79642914See TableBK
    57139783090812965451100.85248314See TableBK
    569981831008121065451000.89450010See TableBK
    569982831208121265451301.02963910See TableBK
    598307831408121465451301.03570410See TableBK
    569983832008122065451151.20093910See TableBK
    569979830609106104451100.83048320See TableBK
    569980830709107104451150.84051617See TableBK
    5956628310091010104451301.02973512See TableBK
    5700068312091012104451301.06784912See TableBK
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item
    * Ampacities are based on TABLE 400.5(A)(1) of the 2023 National Electrical Code and CEC Table 12.
    Table 2 – Weights and Measurements (Metric)
    Stock NumberCCI Part #Cond. SizeCond. NumberCond. StrandsInsul. ThicknessJacket ThicknessApprox. ODApprox. WeightAmpacity *Insul. ColorJacket Color
    AWG/KcmilNo.No.mmmmmmkg/kmAmp
    558236830605186160.762.1612.402045See TableBK
    558237830705187160.762.0312.402054See TableBK
    558238830805188160.762.1613.232414See TableBK
    5700348310051810160.762.2915.142983See TableBK
    5700378312051812160.762.2915.673363See TableBK
    5983028314051814160.762.2916.263773See TableBK
    5700398316051816160.762.5416.974203See TableBK
    5700428320051820160.762.4118.774913See TableBK
    5700438324051824160.762.7921.086093See TableBK
    5716928330051830160.762.5422.056793See TableBK
    558232830606166260.762.2913.112508See TableBK
    558233830706167260.762.2914.332997See TableBK
    558234830806168260.762.2914.383087See TableBK
    5605268310061610260.762.2916.464035See TableBK
    5605278312061612260.762.6717.684825See TableBK
    5983058314061614260.762.7918.475025See TableBK
    5700188320061620260.762.4118.925895See TableBK
    5605288316061616260.762.7919.765555See TableBK
    5700198324061624260.762.7923.347544See TableBK
    5700268330061630260.763.3024.949634See TableBK
    558149830607146411.142.6716.8748112See TableBK
    558150830707147411.142.4118.0846410See TableBK
    558230830807148411.142.9218.5451510See TableBK
    5699948310071410411.142.7919.566017See TableBK
    5712708312071412411.142.7922.437017See TableBK
    5699958314071414411.143.3024.898967See TableBK
    5699978316071416411.143.3025.819557See TableBK
    558144830608126651.142.7918.8056416See TableBK
    558145830708127651.142.4118.8052514See TableBK
    558146830808128651.142.7920.2263814See TableBK
    571397830908129651.142.7921.6471914See TableBK
    5699818310081210651.142.5422.7174410See TableBK
    5699828312081212651.143.3026.1495110See TableBK
    5983078314081214651.143.3026.29104810See TableBK
    5699838320081220651.142.9230.48139710See TableBK
    5699798306091061041.142.7921.0871920See TableBK
    5699808307091071041.142.9221.3476817See TableBK
    59566283100910101041.143.3026.14109412See TableBK
    57000683120910121041.143.3027.10126312See TableBK
    * Ampacities are based on TABLE 400.5(A)(1) of the 2023 National Electrical Code and CEC Table 12.

    Color Table

    Stock NumberSize (AWG)Conductor NumberInsulation ColorFiller/Binder
    5700341810BK, WE, RD, GN, OE, BE, BK-WE 1xStripe, RD-WE 1xStripe, GN-WE 1xStripe, OE-WE 1xStripeNone/Paper
    5700371812BK, WE, RD, GN, OE, BE, BK-WE 1xStripe, RD-WE 1xStripe, GN-WE 1xStripe, OE-WE 1xStripe, BE-WE 1xStripe, WE-BK 1xStripeNone/Paper
    5983021814BK, WE, RD, GN, OE, BE, BK-WE 1xStripe, RD-WE 1xStripe, GN-WE 1xStripe, OE-WE 1xStripe, BE-WE 1xStripe, WE-BK 1xStripe, RD-BK 1xStripe, GN-BK 1xStripeNone/Paper
    5700391816BK, WE, RD, GN, OE, BE, BK-WE 1xStripe, RD-WE 1xStripe, GN-WE 1xStripe, OE-WE 1xStripe, BE-WE 1xStripe, WE-BK 1xStripe, RD-BK 1xStripe, GN-BK 1xStripe, OE-BK 1xStripe, BE-BK 1xStripeNone/Paper
    5700421820BK, WE, RD, GN, OE, BE, BK-WE 1xStripe, RD-WE 1xStripe, GN-WE 1xStripe, OE-WE 1xStripe, BE-WE 1xStripe, WE-BK 1xStripe, RD-BK 1xStripe, GN-BK 1xStripe, OE-BK 1xStripe, BE-BK 1xStripe, BK-RD 1xStripe, WE-RD 1xStripe, GN-RD 1xStripe, OE-RD 1xStripeNone/Paper
    5700431824BK, WE, RD, GN, OE, BE, BK-WE 1xStripe, RD-WE 1xStripe, GN-WE 1xStripe, OE-WE 1xStripe, BE-WE 1xStripe, WE-BK 1xStripe, RD-BK 1xStripe, GN-BK 1xStripe, OE-BK 1xStripe, BE-BK 1xStripe, BK-RD 1xStripe, WE-RD 1xStripe, GN-RD 1xStripe, OE-RD 1xStripe, BE-RD 1xStripe, BK-WE 2xStripe, RD-WE 2xStripe, GN-WE 2xStripeNone/Paper
    5716921830BK, WE, RD, GN, OE, BE, BK-WE 1xStripe, RD-WE 1xStripe, GN-WE 1xStripe, OE-WE 1xStripe, BE-WE 1xStripe, WE-BK 1xStripe, RD-BK 1xStripe, GN-BK 1xStripe, OE-BK 1xStripe, BE-BK 1xStripe, BK-RD 1xStripe, WE-RD 1xStripe, GN-RD 1xStripe, OE-RD 1xStripe, BE-RD 1xStripe, BK-WE 2xStripe, RD-WE 2xStripe, GN-WE 2xStripe, OE-WE 2xStripe, BE-WE 2xStripe, WE-BK 2xStripe, RD-BK 2xStripe, GN-BK 2xStripe, OE-BK 2xStripeNone/Paper
    5605261610BK, WE, RD, GN, OE, BE, BK-WE 1xStripe, RD-WE 1xStripe, GN-WE 1xStripe, OE-WE 1xStripePaper/Paper
    5605271612BK, WE, RD, GN, OE, BE, BK-WE 1xStripe, RD-WE 1xStripe, GN-WE 1xStripe, OE-WE 1xStripe, BE-WE 1xStripe, WE-BK 1xStripePaper/Paper
    5983051614BK, WE, RD, GN, OE, BE, BK-WE 1xStripe, RD-WE 1xStripe, GN-WE 1xStripe, OE-WE 1xStripe, BE-WE 1xStripe, WE-BK 1xStripe, RD-BK 1xStripe, GN-BK 1xStripePaper/Paper
    5605281616BK, WE, RD, GN, OE, BE, BK-WE 1xStripe, RD-WE 1xStripe, GN-WE 1xStripe, OE-WE 1xStripe, BE-WE 1xStripe, WE-BK 1xStripe, RD-BK 1xStripe, GN-BK 1xStripe, OE-BK 1xStripe, BE-BK 1xStripeNone/Paper
    5700181620BK, WE, RD, GN, OE, BE, BK-WE 1xStripe, RD-WE 1xStripe, GN-WE 1xStripe, OE-WE 1xStripe, BE-WE 1xStripe, WE-BK 1xStripe, RD-BK 1xStripe, GN-BK 1xStripe, OE-BK 1xStripe, BE-BK 1xStripe, BK-RD 1xStripe, WE-RD 1xStripe, GN-RD 1xStripe, OE-RD 1xStripeNone/Paper
    5700191624BK, WE, RD, GN, OE, BE, BK-WE 1xStripe, RD-WE 1xStripe, GN-WE 1xStripe, OE-WE 1xStripe, BE-WE 1xStripe, WE-BK 1xStripe, RD-BK 1xStripe, GN-BK 1xStripe, OE-BK 1xStripe, BE-BK 1xStripe, BK-RD 1xStripe, WE-RD 1xStripe, GN-RD 1xStripe, OE-RD 1xStripe, BE-RD 1xStripe, BK-WE 2xStripe, RD-WE 2xStripe, GN-WE 2xStripeNone/Paper
    5700261630BK, WE, RD, GN, OE, BE, BK-WE 1xStripe, RD-WE 1xStripe, GN-WE 1xStripe, OE-WE 1xStripe, BE-WE 1xStripe, WE-BK 1xStripe, RD-BK 1xStripe, GN-BK 1xStripe, OE-BK 1xStripe, BE-BK 1xStripe, BK-RD 1xStripe, WE-RD 1xStripe, GN-RD 1xStripe, OE-RD 1xStripe, BE-RD 1xStripe, BK-WE 2xStripe, RD-WE 2xStripe, GN-WE 2xStripe, OE-WE 2xStripe, BE-WE 2xStripe, WE-BK 2xStripe, RD-BK 2xStripe, GN-BK 2xStripe, OE-BK 2xStripePaper/Mylar
    5699941410BK, WE, RD, GN, OE, BE, BK-WE 1xStripe, RD-WE 1xStripe, GN-WE 1xStripe, OE-WE 1xStripePaper/Paper
    5712701412BK, WE, RD, GN, OE, BE, BK-WE 1xStripe, RD-WE 1xStripe, GN-WE 1xStripe, OE-WE 1xStripe, BE-WE 1xStripePaper/Paper
    5699951414BK, WE, RD, GN, OE, BE, BK-WE 1xStripe, RD-WE 1xStripe, GN-WE 1xStripe, OE-WE 1xStripe, BE-WE 1xStripe, WE-BK 1xStripe, RD-BK 1xStripe, GN-BK 1xStripePaper/Paper
    5699971416BK, WE, RD, GN, OE, BE, BK-WE 1xStripe, RD-WE 1xStripe, GN-WE 1xStripe, OE-WE 1xStripe, BE-WE 1xStripe, WE-BK 1xStripe, RD-BK 1xStripe, GN-BK 1xStripe, OE-BK 1xStripe, BE-BK 1xStripePaper/String
    571397129BK, WE, RD, GN, OE, BE, BK-WE 1xStripe, RD-WE 1xStripe, GN-WE 1xStripeNone/Paper
    5699811210BK, WE, RD, GN, OE, BE, BK-WE 1xStripe, RD-WE 1xStripe, GN-WE 1xStripe, OE-WE 1xStripePaper/Paper
    5699821212BK, WE, RD, GN, OE, BE, BK-WE 1xStripe, RD-WE 1xStripe, GN-WE 1xStripe, OE-WE 1xStripe, BE-WE 1xStripe, WE-BK 1xStripeNone/Paper
    5983071214BK, WE, RD, GN, OE, BE, BK-WE 1xStripe, RD-WE 1xStripe, GN-WE 1xStripe, OE-WE 1xStripe, BE-WE 1xStripe, WE-BK 1xStripe, RD-BK 1xStripe, GN-BK 1xStripePaper/Paper
    5699831220BK, WE, RD, GN, OE, BE, BK-WE 1xStripe, RD-WE 1xStripe, GN-WE 1xStripe, OE-WE 1xStripe, BE-WE 1xStripe, WE-BK 1xStripe, RD-BK 1xStripe, GN-BK 1xStripe, OE-BK 1xStripe, BE-BK 1xStripe, BK-RD 1xStripe, WE-RD 1xStripe, GN-RD 1xStripe, OE-RD 1xStripePoly/Paper
    5956621010BK, WE, RD, GN, OE, BE, BK-WE 1xStripe, RD-WE 1xStripe, GN-WE 1xStripe, OE-WE 1xStripePaper/Paper
    5700061012BK, WE, RD, GN, OE, BE, BK-WE 1xStripe, RD-WE 1xStripe, GN-WE 1xStripe, OE-WE 1xStripe, BE-WE 1xStripe, WE-BK 1xStripeNone/Paper

    Revision: 1.000.059

    Updated On: April 30, 2025, 2:16 p.m. UTC