SPEC 13152

Category 6 CMP-LP

Category 6 250 MHz CMP-LP

...

Construction:

  1. Conductor:Bare solid copper
  2. Insulation:Fluorinated Polyethylene (FPE)
  3. Separator:Spline separator cabled and jacketed
  4. Rip Cord:Rip cord for ease of jacket removal
  5. Jacket:Flame Retardant Polyvinyl Chloride (PVC)

Applications and Features:

Southwire Cat 6 unshielded twisted pair cable is a high performance data communication cable. This ethernet cable is designed for indoor and riser network installations type CMP (Plenum rated communication cable), may be used in Ethernet Networking system, PoE applications, Video MPEG4 / M-JPEG/ Digital / Analog / Baseband / Broadband and other Multimedia Voice applications.

  • DC Resistance: <9.38 Ω/100m
  • DC Resistance Unbalance: <5.00%
  • Mutual Capacitance: <5.60 nF/100m
  • Capacitance Unbalance (Pair to Ground): <330 pF/100m
  • Insulation Resistance: >500 MΩ/100m
  • Dielectric Strength: 2.5 DCkV/sec
  • Impedance (mean): >100+/- 15% (1 < freq < 250MHz)
  • Propagation Delay Skew: <45 nano sec /100m
  • Specifications:

  • UL 444 Listed CMP
  • IEEE 802.3 and IEC 61156-5 Ed. 2.0
  • RoHS-3 Complies with European Directive 2015/863
  • NFPA 262
  • TIA/EIA 568.D.2 (Cat.6) Standard
  • NEC Article 800
  • Sample Print Legend:

    6P CAT6 SOUTHWIRE® TAPPAN™ I99993 E118871 LBI 23AWG 4PR UTP TYPE CMP LP ( 105 C C(UL)US LISTED TYPE CMP FT6 UL VERIFIED TO TIA/EIA 568.D.2 RoHS 2 COMPLIANT XX/XX/XX/XX 0000FT
    Table 1 – Weights and Measurements
    Stock NumberCond. SizeNumber of PairsJacket ThicknessApprox. ODApprox. Weight
    AWG/Kcmilpairmilinchlb/1000ft
    I99993234180.21326
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item
    Table 2 – Weights and Measurements (Metric)
    Stock NumberCond. SizeNumber of PairsJacket ThicknessApprox. ODApprox. Weight
    AWG/Kcmilpairmmmmlb/km
    I999932340.465.4139

    Electrical Performance

    Freq.
    (MHz)
    Attenuation
    (dB/100m)Max
    NEXT
    (dB/100m) Min
    PSNEXT
    (dB/100m)Min
    ELFEXT
    (dB/100m)Min
    PSELFEXT
    (dB/100m)Min
    TCL
    (dB/100m) Min
    RL
    (dB/100m) Min
    P.Delay
    (ns/100m)Max
    1274.372.367.864.84020570
    43.865.363.355.852.84023552
    85.560.858.849.746.74024.5547
    10659.357.347.844.84025545
    167.656.254.243.740.73825543
    208.554.852.841.838.83725542
    259.553.351.339.836.83624.3541
    31.2510.751.949.937.934.935.123.6540
    62.515.447.445.431.928.93221.5539
    10019.844.342.327.824.83020.1538
    2002939.837.821.818.82718537
    25032.838.336.319.816.82617.3536

    Revision: 1.000.131