SPEC 13057

OSDP Access Control

OSDP COMPOSITE CABLE - Four Cable Component Assemblies 60°C , 300V Plenum Rated

...

Construction:

  1. Door:Number of Conductors: 4/C 22AWG Stranded Bare Copper.
    * Conductor Insulation: Plenum Polymer. Color Code: Black, Red, White, Green
    * Jacket: Plenum Polymer. Color: White/Red Stripe.
    * Rip Cord: Nylon
    * Nominal Diameter: 0.116 inch
  2. REX/Spare:Number of Conductors: 2/C 22AWG Stranded Bare Copper.
    * Conductor Insulation: Plenum Polymer. Color Code: Black, Red
    * Jacket: Plenum Polymer. Color: White/Green Stripe.
    * Rip Cord: Nylon
    * Nominal Diameter: 0.133 inch
  3. OSDP:Number of Conductors: 2/C 18AWG Stranded Bare Copper + 2/C 22AWG Tinned Copper Shielded
    * Insulation: Plenum Polymer on 18 AWG (Blk & Red) & Foam FEP on 22 AWG (Green & White). 22AWG 1pr shielded : Aluminum/Polyester, 24AWG Stranded Tin Copper
    * Jacket: Plenum Polymer. Color: White.
    * Low CAP Cable Electricals: 120 ohm Impedance; 12.5 pF/ft Capacitance
    * Rip Cord: Nylon
    * Nominal Diameter: 0.220 inch
  4. Lock Power: Number of Conductors: 4/C 18AWG Stranded Bare
    * Insulation: Plenum Polymer Color Code: Black, Red, White, Green
    * Jacket: Plenum Polymer. Color: White/Orange Stripe.
    * Rip Cord: Nylon
    * Nominal Diameter: 0.174 inch
  5. Overall Construction Four components are cabled together and overall jacketed
    * Jacket: Remguard Plenum Polymer, Color: Yellow
    * Jacket Thickness: 15 mils
    * Nominal Diameter: 0.414 inch
Part Number : H93001

Applications and Features:

Access control doors with four functions, typically device dependent. General purpose low voltage and power-limited systems' circuits to NEC Articles 725 and 800

  • Voltage: 300 Volts
  • Temperature: 75ºC
  • Specifications:

  • ASTM B3 Soft or Annealed Copper Wire
  • UL 444 Communications Cables (90ºC, 300V)
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661
  • Sample Print Legend:

    SOUTHWIRE OSDP COMPOSITE CABLE CMP 6/18AWG 8/22AWG C(ETL)US RS-485

    Table 1 – Weights and Measurements

    Stock CodeCond. SizeJacket ThicknessJacket ThicknessNominal ODNominal ODNominal WeightNominal Weight
    (AWG)milsmmInchmmLbs/Mftkg/km
    H930016 cable assy 18 AWG And 8 cable assy 22 AWG150.3810.41710.59292136.9

    Revision: 1.000.031

    Updated On: Dec. 13, 2024, 4:48 p.m. UTC