SPEC 10025

SIMpull CoilPAK™ Wire Payoff

Work smarter with the SIMpull CoilPAK™ Wire Payoff by reducing the physical effort associated with material handling, setup, and pulling compared to traditional spools, increasing both safety and productivity on the job.

...

Construction:

  1. Conductor:Solid soft drawn bare copper per ASTM B3 or combination-unilay stranded soft drawn bare copper per ASTM B787
  2. Insulation:Heat and moisture resistant PVC insulation in various colors
  3. Sheath:Nylon jacket utilizing SIMpull®Technology

  4. For information about our SIMpull CoilPAK™ Wire Payoff please visit us at:  SIMpull CoilPAK™ Wire Payoff

Applications and Features:

The SIMpull CoilPAK™ Wire Payoff provides greater versatility and efficiency to branch circuit installations, eliminating the need for handling bulky spools and all the setup and energy that go along with them. SIMpull CoilPAK™ Wire Payoffs increase both safety and productivity by reducing the physical effort associated with material handling, pulling wire out of the package, and pulling wire through conduit.

Specifications:

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B787 19 Wire Combination Unilay-Stranded Copper Conductors
  • UL 83 Thermoplastic Insulated Wires and Cables
  • NMX-J-010-ANCE Thermoplastic insulated wires and cables
  • NOM-063-SCFI Electrical Products – Conductors – Safety Requirements
  • Table 1 – Weights and Measurements
    Stock NumberCond. SizeCond. NumberStrand CountDiameter Over ConductorInsul. ThicknessJacket ThicknessApprox. ODCopper WeightApprox. Weight
    AWG/KcmilNo. of Strandsinchmilmilinchlb/1000ftlb/1000ft
    58062205141Solid0.0641650.1061215
    58028605141Solid0.0641650.1061215
    58029105141Solid0.0641650.1061215
    58028905141Solid0.0641650.1061215
    58029505141Solid0.0641650.1061215
    58029205141Solid0.0641650.1061215
    58028805141Solid0.0641650.1061215
    58029405141Solid0.0641650.1061215
    58028705141Solid0.0641650.1061215
    58029305141Solid0.0641650.1061215
    58028505141Solid0.0641650.1061215
    58189905141190.0731650.1131216
    58189805141190.0731650.1131216
    58017805141190.0731650.1131216
    58017605141190.0731650.1131216
    58017305141190.0731650.1131216
    58018105141190.0731650.1131216
    58017705141190.0731650.1131216
    58017205141190.0731650.1131216
    58018005141190.0731650.1131216
    58017105141190.0731650.1131216
    58017905141190.0731650.1131216
    58017005141190.0731650.1131216
    58017606141190.0731650.1131216
    58193305141190.0731650.1131216
    58027905121Solid0.0801650.1221923
    58026305121Solid0.0801650.1221923
    58027805121Solid0.0801650.1221923
    58027705121Solid0.0801650.1221923
    58456605121Solid0.0801650.1221923
    58028305121Solid0.0801650.1221923
    58028105121Solid0.0801650.1221923
    58028005121Solid0.0801650.1221923
    58193105121Solid0.0801650.1221923
    58026405121Solid0.0801650.1221923
    58027105121Solid0.0801650.1221923
    58026905121Solid0.0801650.1221923
    58027605121Solid0.0801650.1221923
    58027205121Solid0.0801650.1221923
    58026805121Solid0.0801650.1221923
    58027505121Solid0.0801650.1221923
    58026705121Solid0.0801650.1221923
    58027305121Solid0.0801650.1221923
    58026505121Solid0.0801650.1221923
    58026404121Solid0.0801650.1221923
    58026504121Solid0.0801650.1221923
    58026704121Solid0.0801650.1221923
    58026804121Solid0.0801650.1221923
    58026904121Solid0.0801650.1221923
    58027104121Solid0.0801650.1221923
    58027204121Solid0.0801650.1221923
    58027304121Solid0.0801650.1221923
    58027504121Solid0.0801650.1221923
    58027604121Solid0.0801650.1221923
    58027704121Solid0.0801650.1221923
    58027804121Solid0.0801650.1221923
    58027904121Solid0.0801650.1221923
    58028004121Solid0.0801650.1221923
    58028104121Solid0.0801650.1221923
    58028304121Solid0.0801650.1221923
    58193104121Solid0.0801650.1221923
    58456604121Solid0.0801650.1221923
    58614504122Solid0.0801650.1221923
    58614704122Solid0.0801650.1221923
    58614804122Solid0.0801650.1221923
    58619404122Solid0.0801650.1221923
    58619504122Solid0.0801650.1221923
    58614401122Solid0.0801550.2453947
    58614404122Solid0.0801550.2453947
    13937005122Solid0.0801550.2453947
    58389701123Solid0.0801550.2453947
    58389703123Solid0.0801550.2453947
    58018805121190.0901650.1322024
    58019005121190.0901650.1322024
    58018905121190.0901650.1322024
    58386305121190.0901650.1322024
    58019405121190.0901650.1322024
    58019305121190.0901650.1322024
    58019205121190.0901650.1322024
    58193205121190.0901650.1322024
    58019505121190.0901650.1322024
    58020005121190.0901650.1322024
    58019605121190.0901650.1322024
    58019905121190.0901650.1322024
    58018405121190.0901650.1322024
    58019805121190.0901650.1322024
    58018204121190.0901550.1322024
    58018205121190.0901650.1322024
    58018404121190.0901550.1322024
    58018504121190.0901550.1322024
    58018604121190.0901550.1322024
    58018704121190.0901550.1322024
    58018904121190.0901550.1322024
    58019004121190.0901550.1322024
    58019204121190.0901550.1322024
    58019304121190.0901550.1322024
    58019404121190.0901550.1322024
    58019504121190.0901550.1322024
    58019604121190.0901550.1322024
    58019704121190.0901550.1322024
    58019804121190.0901550.1322024
    58019904121190.0901550.1322024
    58020004121190.0901550.1322024
    58193204121190.0901550.1322024
    58386304121190.0901550.1322024
    58018705121190.0901550.1322024
    58018605121190.0901550.1322024
    58019705121190.0901550.1322024
    58018505121190.0901550.1322024
    58609704122190.0901550.1322024
    58610004122190.0901550.1322024
    58610104122190.0901550.1322024
    58612004122190.0901550.1322024
    58609501122190.0901550.2604048
    58609504122190.0901550.2604048
    58609604122190.0901550.2604048
    58453301123190.0901550.2604048
    58453303123190.0901550.2604048
    58020105101Solid0.1012150.1533036
    58021005101Solid0.1012150.1533036
    58020805101Solid0.1012150.1533036
    58022605101Solid0.1012150.1533036
    58021205101Solid0.1012150.1533036
    58021905101Solid0.1012150.1533036
    58021805101Solid0.1012150.1533036
    58021605101Solid0.1012150.1533036
    58020205101Solid0.1012150.1533036
    58021105101Solid0.1012150.1533036
    58020605101Solid0.1012150.1533036
    58022005101Solid0.1012150.1533036
    58021305101Solid0.1012150.1533036
    58020505101Solid0.1012150.1533036
    58021505101Solid0.1012150.1533036
    58020405101Solid0.1012150.1533036
    58021405101Solid0.1012150.1533036
    58020305101Solid0.1012150.1533036
    58029705102Solid0.1012050.3036172
    58022705101190.1172150.1653238
    58025905101190.1172150.1653238
    58025705101190.1172150.1653238
    58020705101190.1172150.1653238
    58456705101190.1172150.1653238
    58026205101190.1172150.1653238
    58026105101190.1172150.1653238
    58026005101190.1172150.1653238
    58193005101190.1172150.1653238
    58025305101190.1172150.1653238
    58025005101190.1172150.1653238
    58022305101190.1172150.1653238
    58025505101190.1172150.1653238
    58022205101190.1172150.1653238
    58025405101190.1172150.1653238
    58022105101190.1172150.1653238
    58025205101190.1172050.1653238
    58025605101190.1172050.1653238
    58025105101190.1172050.1653238
    59805002101190.1172050.1653238
    58725101102190.1172050.3266476
    58619401122Solid0.0801550.2453947
    58614801122Solid0.0801550.2453947
    58619501122Solid0.0801550.2453947
    58614701122Solid0.0801550.2453947
    58614501122Solid0.0801550.2453947
    58609701122190.0901550.2604048
    58610101122190.0901550.2604048
    58610001122190.0901550.2604048
    58609601122190.0901550.2604048
    58612001122190.0901550.2604048
    58105505102Solid0.1012050.3036172
    58105005102Solid0.1012050.3036172
    58920505102Solid0.1012050.3036172
    58920605102Solid0.1012050.3036172
    58920705102Solid0.1012050.3036172
    58725501102190.1172050.3266476
    58725601102190.1172050.3266476
    58725701102190.1172050.3266476
    58725201102190.1172050.3266476
    59306201102190.1172050.3266476
    58725401102190.1172050.3306477
    59799501103190.1172050.48396114
    58114302103190.1172050.48996115
    58139402124190.0901550.5208097
    58138504104190.1172050.652128153
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item
    Table 2 – Electrical and Engineering Data
    Stock NumberCond. SizeCond. NumberMin Bending RadiusMax Pull TensionDC Resistance @ 25°CAC Resistance @ 75°CInductive Reactance @ 60HzAllowable Ampacity At 75°CAllowable Ampacity At 90°C
    AWG/KcmilinchlbΩ/1000ftΩ/1000ftΩ/1000ftAmpAmp
    580622051410.4322.6313.1700.0582025
    580286051410.4322.6313.1700.0582025
    580291051410.4322.6313.1700.0582025
    580289051410.4322.6313.1700.0582025
    580295051410.4322.6313.1700.0582025
    580292051410.4322.6313.1700.0582025
    580288051410.4322.6313.1700.0582025
    580294051410.4322.6313.1700.0582025
    580287051410.4322.6313.1700.0582025
    580293051410.4322.6313.1700.0582025
    580285051410.4322.6313.1700.0582025
    581899051410.5322.6313.1700.0582025
    581898051410.5322.6313.1700.0582025
    580178051410.5322.6313.1700.0582025
    580176051410.5322.6313.1700.0582025
    580173051410.5322.6313.1700.0582025
    580181051410.5322.6313.1700.0582025
    580177051410.5322.6313.1700.0582025
    580172051410.5322.6313.1700.0582025
    580180051410.5322.6313.1700.0582025
    580171051410.5322.6313.1700.0582025
    580179051410.5322.6313.1700.0582025
    580170051410.5322.6313.1700.0582025
    580176061410.5322.6313.1700.0582025
    581933051410.5322.6313.1700.0582025
    580279051210.5521.6622.0020.0542530
    580263051210.5521.6622.0020.0542530
    580278051210.5521.6622.0020.0542530
    580277051210.5521.6622.0020.0542530
    584566051210.5521.6622.0020.0542530
    580283051210.5521.6622.0020.0542530
    580281051210.5521.6622.0020.0542530
    580280051210.5521.6622.0020.0542530
    581931051210.5521.6622.0020.0542530
    580264051210.5521.6622.0020.0542530
    580271051210.5521.6622.0020.0542530
    580269051210.5521.6622.0020.0542530
    580276051210.5521.6622.0020.0542530
    580272051210.5521.6622.0020.0542530
    580268051210.5521.6622.0020.0542530
    580275051210.5521.6622.0020.0542530
    580267051210.5521.6622.0020.0542530
    580273051210.5521.6622.0020.0542530
    580265051210.5521.6622.0020.0542530
    580264041210.5521.6622.0020.0542530
    580265041210.5521.6622.0020.0542530
    580267041210.5521.6622.0020.0542530
    580268041210.5521.6622.0020.0542530
    580269041210.5521.6622.0020.0542530
    580271041210.5521.6622.0020.0542530
    580272041210.5521.6622.0020.0542530
    580273041210.5521.6622.0020.0542530
    580275041210.5521.6622.0020.0542530
    580276041210.5521.6622.0020.0542530
    580277041210.5521.6622.0020.0542530
    580278041210.5521.6622.0020.0542530
    580279041210.5521.6622.0020.0542530
    580280041210.5521.6622.0020.0542530
    580281041210.5521.6622.0020.0542530
    580283041210.5521.6622.0020.0542530
    581931041210.5521.6622.0020.0542530
    584566041210.5521.6622.0020.0542530
    586145041220.5521.6622.0020.0542530
    586147041220.5521.6622.0020.0542530
    586148041220.5521.6622.0020.0542530
    586194041220.5521.6622.0020.0542530
    586195041220.5521.6622.0020.0542530
    586144011221.01041.6622.0020.0542530
    586144041221.01041.6622.0020.0542530
    139370051221.01041.6622.0020.0542530
    583897011231.01041.6622.0020.0542530
    583897031231.01041.6622.0020.0542530
    580188051210.5521.6622.0020.0542530
    580190051210.5521.6622.0020.0542530
    580189051210.5521.6622.0020.0542530
    583863051210.5521.6622.0020.0542530
    580194051210.5521.6622.0020.0542530
    580193051210.5521.6622.0020.0542530
    580192051210.5521.6622.0020.0542530
    581932051210.5521.6622.0020.0542530
    580195051210.5521.6622.0020.0542530
    580200051210.5521.6622.0020.0542530
    580196051210.5521.6622.0020.0542530
    580199051210.5521.6622.0020.0542530
    580184051210.5521.6622.0020.0542530
    580198051210.5521.6622.0020.0542530
    580182041210.5521.6622.0020.0542530
    580182051210.5521.6622.0020.0542530
    580184041210.5521.6622.0020.0542530
    580185041210.5521.6622.0020.0542530
    580186041210.5521.6622.0020.0542530
    580187041210.5521.6622.0020.0542530
    580189041210.5521.6622.0020.0542530
    580190041210.5521.6622.0020.0542530
    580192041210.5521.6622.0020.0542530
    580193041210.5521.6622.0020.0542530
    580194041210.5521.6622.0020.0542530
    580195041210.5521.6622.0020.0542530
    580196041210.5521.6622.0020.0542530
    580197041210.5521.6622.0020.0542530
    580198041210.5521.6622.0020.0542530
    580199041210.5521.6622.0020.0542530
    580200041210.5521.6622.0020.0542530
    581932041210.5521.6622.0020.0542530
    583863041210.5521.6622.0020.0542530
    580187051210.5521.6622.0020.0542530
    580186051210.5521.6622.0020.0542530
    580197051210.5521.6622.0020.0542530
    580185051210.5521.6622.0020.0542530
    586097041220.5521.6622.0020.0542530
    586100041220.5521.6622.0020.0542530
    586101041220.5521.6622.0020.0542530
    586120041220.5521.6622.0020.0542530
    586095011221.01041.6622.0020.0542530
    586095041221.01041.6622.0020.0542530
    586096041221.01041.6622.0020.0542530
    584533011231.01041.6622.0020.0542530
    584533031231.01041.6622.0020.0542530
    580201051010.6831.0401.2530.0503540
    580210051010.6831.0401.2530.0503540
    580208051010.6831.0401.2530.0503540
    580226051010.6831.0401.2530.0503540
    580212051010.6831.0401.2530.0503540
    580219051010.6831.0401.2530.0503540
    580218051010.6831.0401.2530.0503540
    580216051010.6831.0401.2530.0503540
    580202051010.6831.0401.2530.0503540
    580211051010.6831.0401.2530.0503540
    580206051010.6831.0401.2530.0503540
    580220051010.6831.0401.2530.0503540
    580213051010.6831.0401.2530.0503540
    580205051010.6831.0401.2530.0503540
    580215051010.6831.0401.2530.0503540
    580204051010.6831.0401.2530.0503540
    580214051010.6831.0401.2530.0503540
    580203051010.6831.0401.2530.0503540
    580297051021.21661.0401.2530.0503540
    580227051010.7831.0401.2530.0503540
    580259051010.7831.0401.2530.0503540
    580257051010.7831.0401.2530.0503540
    580207051010.7831.0401.2530.0503540
    584567051010.7831.0401.2530.0503540
    580262051010.7831.0401.2530.0503540
    580261051010.7831.0401.2530.0503540
    580260051010.7831.0401.2530.0503540
    581930051010.7831.0401.2530.0503540
    580253051010.7831.0401.2530.0503540
    580250051010.7831.0401.2530.0503540
    580223051010.7831.0401.2530.0503540
    580255051010.7831.0401.2530.0503540
    580222051010.7831.0401.2530.0503540
    580254051010.7831.0401.2530.0503540
    580221051010.7831.0401.2530.0503540
    580252051010.7831.0401.2530.0503540
    580256051010.7831.0401.2530.0503540
    580251051010.7831.0401.2530.0503540
    598050021010.7831.0401.2530.0503540
    587251011021.31661.0401.2530.0503540
    586194011221.01041.6622.0020.0542530
    586148011221.01041.6622.0020.0542530
    586195011221.01041.6622.0020.0542530
    586147011221.01041.6622.0020.0542530
    586145011221.01041.6622.0020.0542530
    586097011221.01041.6622.0020.0542530
    586101011221.01041.6622.0020.0542530
    586100011221.01041.6622.0020.0542530
    586096011221.01041.6622.0020.0542530
    586120011221.01041.6622.0020.0542530
    581055051021.21661.0401.2530.0503540
    581050051021.21661.0401.2530.0503540
    589205051021.21661.0401.2530.0503540
    589206051021.21661.0401.2530.0503540
    589207051021.21661.0401.2530.0503540
    587255011021.31661.0401.2530.0503540
    587256011021.31661.0401.2530.0503540
    587257011021.31661.0401.2530.0503540
    587252011021.31661.0401.2530.0503540
    593062011021.31661.0401.2530.0503540
    587254011021.31661.0401.2530.0503540
    597995011031.92491.0401.2530.0503540
    581143021032.02491.0401.2530.0503540
    581394021242.11671.6622.0020.0542024
    581385041042.62651.0401.2530.0502832
    *Ampacities based upon 2023 NEC Table 310.16 and do not take into account the overcurrent protection limitations in NEC 240.4(D) of 15 Amps for 14 AWG CU, 20 Amps for 12 AWG CU, and 30 Amps for 10 AWG CU (independent of the conductor temperature rating and stranding if size is present in table). Also, see NEC sections 310.15 and 110.14(C) for additional requirements.
    * Inductive Reactance is based on non-ferrous conduit with one diameter spacing center-to-center.

    Table 3 - One Conductor Stock Code Colors ( / means stripe. Blue/White: Blue with White Stripe)

    Size (Strand)Cond.
    Number
    BlueBlackBrownGreenGreen/YellowGrayGray/BrownGray/OrangeGray/PurpleGray/Yellow
    14 (Solid)15802870558028505580288055802910558028905
    14 (19)15801710558017005580172055801760558017305
    12 (Solid)158026705580265055802680558027105584566055802690558027705580278055802630558027905
    12 (19)158018405580182055801850558019505583863055801860558018705580189055801880558019005
    10 (Solid)158020405580203055802050558021105580212055802060558022605580208055802010558021005
    10 (19)158022205580221055802230558025105584567055802500558020705580257055802270558025905

    Table 3 Cont. - One Conductor Stock Code Colors ( / means stripe. Blue/White: Blue with White Stripe)

    Size (Strand)Cond.
    Number
    OrangePurplePinkRedTanWhiteWhite/BlueWhite/BlackWhite/RedYellow
    14 (Solid)1580292055802860558029305580294055806220558029505
    14 (19)15801770558017805581933055801790558018005581899055818980558018105
    12 (Solid)1580272055802640558193105580273055802750558028105580280055802830558027605
    12 (19)1580196055801970558193205580198055801990558019305580192055801940558020005
    10 (Solid)15802130558020205580214055802150558021805580216055802190558022005
    10 (19)158025205580253055819300558025405598050025802550558026105580260055802620558025605

    Table 4 - Multi Conductor Stock Code Colors ( / means stripe. Blue/White: Blue with White Stripe)

    Size (Strand)Cond.
    Number
    Blue, White/BlueBlack, RedBlack, White/BlackBrown, Gray/BrownOrange, Gray/OrangeRed, White/RedYellow, Gray/YellowBrown, Orange, YellowBlack, Red, GreenBlack, White, GreenBrown, Orange, Yellow, Green
    12 (Solid)2586145015861940158619501586147015861440158614801
    12 (19)2586097015860950158612001586100015860960158610101
    10 (Solid)2581050055802970558920505589207055810550558920605
    10 (19)258725401593062015872510158725701587255015872520158725601
    12(Solid)358389701
    12(19)358453301
    10(19)35811430259799501
    12(19)458139402
    10(19)458138504

    Table 5 - MINI One Conductor Stock Code Colors ( / means stripe. Blue/White: Blue with White Stripe)

    Size (Strand)Cond.
    Number
    BlueBlackBrownGreenGreen/YellowGrayGray/BrownGray/OrangeGray/Yellow
    14 (19)158017606
    12 (Solid)1580267045802650458026804580271045845660458026904580277045802780458027904
    12 (19)1580184045801820458018504580195045838630458018604580187045801890458019004

    Table 5 Cont. - MINI One Conductor Stock Code Colors ( / means stripe. Blue/White: Blue with White Stripe)

    Size (Strand)Cond.
    Number
    OrangePurplePinkRedWhiteWhite/BlueWhite/BlackWhite/RedYellow
    12 (Solid)1580272045802640458193104580273045802750458028104580280045802830458027604
    12 (19)1580196045801970458193204580198045801990458019304580192045801940458020004

    Table 6 - MINI Multi Conductor Stock Code Colors ( / means stripe. Blue/White: Blue with White Stripe)

    Size (Strand)Cond.
    Number
    Blue, White/BlueBlack, White/BlackBrown, Gray/BrownOrange, Gray/OrangeRed, White/RedYellow, Gray/YellowBlack, White, Green
    12 (Solid)2586145045861940458619504586147045861440458614804
    12 (19)2586097045860950458612004586100045860960458610104
    12 (Solid)358389703
    12 (19)358453303