SPEC 87100
Tracer Wire
Construction:
- Conductor:Solid bare copper per ASTM B3
- Insulation:Polyethylene (PE)
Applications and Features:
Specifications:
Table 1 – Weights and Measurements
All dimensions are nominal and subject to normal manufacturing tolerances
◊ Cable marked with this symbol is a standard stock item
Table 2 – Insulation Colors & Applications
Conductor Size | ||||||||
---|---|---|---|---|---|---|---|---|
Insulation Color | Application | 18 AWG | 16 AWG | 14 AWG | 12 AWG | 10 AWG | 8 AWG | |
Red | Electrical Power Line | X | X | |||||
Yellow | Natural Gas Pipeline | X | X | X | X | |||
Green | Sewer Pipeline | X | X | X | X | |||
Blue | Potable Water Pipeline | X | X | X | X | |||
Purple | Reclaimed Water, Irrigation, or Slurry Lines | X | ||||||
Black | Pet Containment / Invisible Fence | X | X |
Revision: 1.000.042
Updated On: Sept. 24, 2024, 7:37 p.m. UTC