SPEC 80102
ACSR/AW
Aluminum Conductor, Aluminum-Clad Steel Reinforced

Construction:
- Core: Stranded standard strength aluminum-clad steel core
- Stranding: Hard-drawn aluminum (1350-H19) round wire shaped strands with 61.2% conductivity
Applications and Features:
ACSR/AW (Aluminum Conductor, Aluminum-Clad Steel Reinforced) is a concentrically stranded conductor consisting of one or more layers of hard-drawn aluminum (1350-H19) wires surrounding an aluminum-clad steel core. The aluminum strands provide efficient electrical conductivity, while the aluminum-clad steel core supplies strength, improved sag performance, and enhanced corrosion resistance. ACSR/AW is widely used for overhead transmission and distribution applications where a combination of ampacity, strength, corrosion protection, and long-term reliability is required.
Continuous operating temperature - 75°C
Emergency operating temperature - 100°C
Continuous operating temperature - 75°C
Emergency operating temperature - 100°C
Specifications:
Weights, Measurements, Electrical and Engineering Data
| Stock Number | Code Word | Conductor Size | Stranding | Cross-Sectional Area | Layers of Al | Diameter | Weight | Rated Breaking Strength | DC Resistance @ 20°C | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Individual Strands | AW Core | Complete Conductor | |||||||||||||
| Al | Total | Al | AW | Al | Total | AW2 | AW3 | ||||||||
| AWG/kcmil | Al/AW | in² | in² | in | in | in | in | lb/1000ft | lb/1000ft | lb | lb | Ω/mile | |||
| TBA | SWAN/AW | 4 | 6/1 | 0.0328 | 0.0383 | 1 | 0.0834 | 0.0834 | 0.0834 | 0.250 | 38.95 | 54.66 | 1,780 | 1,860 | 2.0583 |
| TBA | SWANATE/AW | 4 | 7/1 | 0.0328 | 0.0411 | 1 | 0.0772 | 0.1029 | 0.1029 | 0.257 | 38.95 | 62.66 | 2,280 | 2,360 | 2.0037 |
| TBA | SPARROW/AW | 2 | 6/1 | 0.0522 | 0.0609 | 1 | 0.1052 | 0.1052 | 0.1052 | 0.316 | 61.99 | 86.85 | 2,760 | 2,850 | 1.2937 |
| TBA | SPARATE/AW | 2 | 7/1 | 0.0522 | 0.0655 | 1 | 0.0974 | 0.1299 | 0.1299 | 0.325 | 61.99 | 99.99 | 3,510 | 3,640 | 1.2583 |
| TBA | ROBIN/AW | 1 | 6/1 | 0.0657 | 0.0767 | 1 | 0.1181 | 0.1181 | 0.1181 | 0.354 | 78.02 | 109.5 | 3,450 | 3,550 | 1.0277 |
| TBA | RAVEN/AW | 1/0 | 6/1 | 0.0830 | 0.0968 | 1 | 0.1327 | 0.1327 | 0.1327 | 0.398 | 98.57 | 138.0 | 4,250 | 4,380 | 0.8138 |
| TBA | QUAIL/AW | 2/0 | 6/1 | 0.1045 | 0.1219 | 1 | 0.1489 | 0.1489 | 0.1489 | 0.447 | 124.1 | 173.8 | 5,130 | 5,300 | 0.6463 |
| TBA | PIGEON/AW | 3/0 | 6/1 | 0.1317 | 0.1537 | 1 | 0.1672 | 0.1672 | 0.1672 | 0.502 | 156.4 | 219.3 | 6,300 | 6,620 | 0.5127 |
| TBA | PENGUIN/AW | 4/0 | 6/1 | 0.1662 | 0.1939 | 1 | 0.1878 | 0.1878 | 0.1878 | 0.563 | 197.4 | 276.5 | 7,690 | 8,350 | 0.4063 |
| TBA | MAGPIE/AW | 20.87 | 3/4 | 0.0164 | 0.0383 | 0.5 | 0.0834 | 0.0834 | --- | 0.250 | 19.48 | 82.74 | 4,100 | 4,420 | 3.0091 |
| TBA | SHRIKE/AW | 33.185 | 3/4 | 0.0261 | 0.0609 | 0.5 | 0.1052 | 0.1052 | --- | 0.316 | 31.00 | 131.5 | 6,490 | 6,830 | 1.8917 |
| TBA | SNIPE/AW | 52.77 | 3/4 | 0.0414 | 0.0966 | 0.5 | 0.1326 | 0.1326 | --- | 0.398 | 49.16 | 208.7 | 10,000 | 10,500 | 1.1926 |
| TBA | ALBATROSS/AW | 54.95 | 7/1 | 0.0432 | 0.0542 | 1 | 0.0886 | 0.1181 | 0.1181 | 0.295 | 51.30 | 82.73 | 2,980 | 3,080 | 1.5206 |
| TBA | SHOEBILL/AW | 57.50 | 3/4 | 0.0451 | 0.1053 | 0.5 | 0.1384 | 0.1384 | --- | 0.415 | 53.56 | 227.5 | 10,600 | 11,500 | 1.0944 |
| TBA | LOON/AW | 66.54 | 3/4 | 0.0522 | 0.1219 | 0.5 | 0.1489 | 0.1489 | --- | 0.447 | 61.99 | 263.3 | 11,900 | 12,600 | 0.9454 |
| TBA | GROUSE/AW | 80.00 | 8/1 | 0.0628 | 0.0846 | 1 | 0.1000 | 0.1667 | 0.1667 | 0.367 | 74.95 | 137.2 | 4,880 | 5,190 | 1.0213 |
| TBA | PETREL/AW | 101.8 | 12/7 | 0.0799 | 0.1265 | 1 | 0.0921 | 0.0921 | 0.2763 | 0.461 | 95.82 | 229.5 | 9,910 | 10,400 | 0.7526 |
| TBA | MINORCA/AW | 110.8 | 12/7 | 0.0870 | 0.1378 | 1 | 0.0961 | 0.0961 | 0.2883 | 0.481 | 104.3 | 250.0 | 10,800 | 11,300 | 0.6911 |
| TBA | LEGHORN/AW | 134.6 | 12/7 | 0.1057 | 0.1674 | 1 | 0.1059 | 0.1059 | 0.3177 | 0.530 | 126.8 | 303.8 | 13,000 | 13,600 | 0.5689 |
| TBA | GUINEA/AW | 159.0 | 12/7 | 0.1249 | 0.1977 | 1 | 0.1151 | 0.1151 | 0.3453 | 0.576 | 149.8 | 358.6 | 15,300 | 16,000 | 0.4815 |
| TBA | DOTTEREL/AW | 176.9 | 12/7 | 0.1389 | 0.2199 | 1 | 0.1214 | 0.1214 | 0.3642 | 0.607 | 166.6 | 399.0 | 16,900 | 17,300 | 0.4330 |
| TBA | DORKING/AW | 190.8 | 12/7 | 0.1499 | 0.2373 | 1 | 0.1261 | 0.1261 | 0.3783 | 0.631 | 179.8 | 430.5 | 18,300 | 18,700 | 0.4012 |
| TBA | AUK/AW | 203.0 | 8/7 | 0.1594 | 0.2025 | 1 | 0.1593 | 0.0885 | 0.2655 | 0.584 | 190.2 | 313.8 | 10,900 | 11,500 | 0.4121 |
| TBA | BRAHMA/AW | 203.2 | 16/19 | 0.1596 | 0.3020 | 1 | 0.1127 | 0.0977 | 0.4885 | 0.714 | 191.4 | 600.7 | 27,100 | 28,400 | 0.3466 |
| TBA | COCHIN/AW | 211.3 | 12/7 | 0.1660 | 0.2628 | 1 | 0.1327 | 0.1327 | 0.3981 | 0.664 | 199.1 | 476.8 | 19,800 | 20,700 | 0.3623 |
| TBA | JAEGER/AW | 228.2 | 18/1 | 0.1792 | 0.1892 | 2 | 0.1126 | 0.1126 | 0.1126 | 0.563 | 213.9 | 242.5 | 5,920 | 6,020 | 0.3926 |
| TBA | WAXWING/AW | 266.8 | 18/1 | 0.2094 | 0.2210 | 2 | 0.1217 | 0.1217 | 0.1217 | 0.609 | 249.9 | 283.0 | 6,820 | 6,880 | 0.3360 |
| TBA | PARTRIDGE/AW | 266.8 | 26/7 | 0.2095 | 0.2436 | 2 | 0.1013 | 0.0788 | 0.2364 | 0.642 | 251.2 | 349.0 | 10,800 | 11,300 | 0.3258 |
| TBA | JUNCO/AW | 266.8 | 30/7 | 0.2095 | 0.2584 | 2 | 0.0943 | 0.0943 | 0.2829 | 0.660 | 251.9 | 392.2 | 13,500 | 13,900 | 0.3193 |
| TBA | OSTRICH/AW | 300.0 | 26/7 | 0.2355 | 0.2738 | 2 | 0.1074 | 0.0835 | 0.2505 | 0.680 | 282.4 | 392.3 | 12,100 | 12,700 | 0.2899 |
| TBA | MERLIN/AW | 336.4 | 18/1 | 0.2642 | 0.2789 | 2 | 0.1367 | 0.1367 | 0.1367 | 0.684 | 315.3 | 357.3 | 8,540 | 8,680 | 0.2663 |
| TBA | WIDGEON/AW | 336.4 | 24/7 | 0.2642 | 0.2984 | 2 | 0.1184 | 0.0789 | 0.2367 | 0.710 | 316.8 | 414.9 | 12,000 | 12,500 | 0.2612 |
| TBA | LINNET/AW | 336.4 | 26/7 | 0.2640 | 0.3070 | 2 | 0.1137 | 0.0884 | 0.2652 | 0.720 | 316.6 | 440.0 | 13,500 | 14,100 | 0.2586 |
| TBA | ORIOLE/AW | 336.4 | 30/7 | 0.2642 | 0.3259 | 2 | 0.1059 | 0.1059 | 0.3177 | 0.741 | 317.6 | 494.6 | 16,700 | 17,300 | 0.2532 |
| TBA | CHICKADEE/AW | 397.5 | 18/1 | 0.3122 | 0.3295 | 2 | 0.1486 | 0.1486 | 0.1486 | 0.743 | 372.6 | 422.0 | 9,780 | 9,940 | 0.2254 |
| TBA | BRANT/AW | 397.5 | 24/7 | 0.3122 | 0.3527 | 2 | 0.1287 | 0.0858 | 0.2574 | 0.772 | 374.4 | 490.6 | 14,100 | 14,600 | 0.2210 |
| TBA | IBIS/AW | 397.5 | 26/7 | 0.3120 | 0.3628 | 2 | 0.1236 | 0.0961 | 0.2883 | 0.783 | 374.2 | 519.9 | 15,800 | 16,300 | 0.2188 |
| TBA | LARK/AW | 397.5 | 30/7 | 0.3121 | 0.3849 | 2 | 0.1151 | 0.1151 | 0.3453 | 0.806 | 375.2 | 584.0 | 19,600 | 20,300 | 0.2144 |
| TBA | PELICAN/AW | 477.0 | 18/1 | 0.3747 | 0.3955 | 2 | 0.1628 | 0.1628 | 0.1628 | 0.814 | 447.2 | 506.6 | 11,500 | 11,800 | 0.1878 |
| TBA | TOUCAN/AW | 477.0 | 22/7 | 0.3744 | 0.4112 | 2 | 0.1472 | 0.0818 | 0.2454 | 0.834 | 449.0 | 554.6 | 14,700 | 15,200 | 0.1862 |
| TBA | FLICKER/AW | 477.0 | 24/7 | 0.3747 | 0.4233 | 2 | 0.1410 | 0.0940 | 0.2820 | 0.846 | 449.4 | 588.8 | 16,700 | 17,200 | 0.1841 |
| TBA | HAWK/AW | 477.0 | 26/7 | 0.3744 | 0.4354 | 2 | 0.1354 | 0.1053 | 0.3159 | 0.858 | 449.0 | 624.0 | 18,900 | 19,500 | 0.1823 |
| TBA | HEN/AW | 477.0 | 30/7 | 0.3747 | 0.4621 | 2 | 0.1261 | 0.1261 | 0.3783 | 0.883 | 450.5 | 701.2 | 23,400 | 23,800 | 0.1785 |
| TBA | HERON/AW | 500.0 | 30/7 | 0.3927 | 0.4843 | 2 | 0.1291 | 0.1291 | 0.3873 | 0.904 | 472.1 | 734.9 | 24,100 | 25,000 | 0.1704 |
| TBA | OSPREY/AW | 556.5 | 18/1 | 0.4369 | 0.4612 | 2 | 0.1758 | 0.1758 | 0.1758 | 0.879 | 521.4 | 590.8 | 13,200 | 13,700 | 0.1610 |
| TBA | SAPSUCKER/AW | 556.5 | 22/7 | 0.4368 | 0.4797 | 2 | 0.1590 | 0.0883 | 0.2649 | 0.901 | 523.8 | 646.9 | 17,000 | 17,600 | 0.1596 |
| TBA | PARAKEET/AW | 556.5 | 24/7 | 0.4372 | 0.4938 | 2 | 0.1523 | 0.1015 | 0.3045 | 0.914 | 524.3 | 686.7 | 19,300 | 19,800 | 0.1578 |
| TBA | DOVE/AW | 556.5 | 26/7 | 0.4371 | 0.5083 | 2 | 0.1463 | 0.1138 | 0.3414 | 0.927 | 524.2 | 728.4 | 21,900 | 22,600 | 0.1562 |
| TBA | EAGLE/AW | 556.5 | 30/7 | 0.4371 | 0.5391 | 2 | 0.1362 | 0.1362 | 0.4086 | 0.953 | 525.5 | 818.1 | 26,800 | 27,800 | 0.1531 |
| TBA | PEACOCK/AW | 605.0 | 24/7 | 0.4753 | 0.5370 | 2 | 0.1588 | 0.1059 | 0.3177 | 0.953 | 570.0 | 747.0 | 21,000 | 21,600 | 0.1452 |
| TBA | SQUAB/AW | 605.0 | 26/7 | 0.4749 | 0.5522 | 2 | 0.1525 | 0.1186 | 0.3558 | 0.966 | 569.5 | 791.2 | 23,600 | 24,300 | 0.1437 |
| TBA | WOOD DUCK/AW | 605.0 | 30/7 | 0.4751 | 0.5860 | 2 | 0.1420 | 0.1420 | 0.4260 | 0.994 | 571.2 | 889.3 | 28,400 | 28,900 | 0.1408 |
| TBA | TEAL/AW | 605.0 | 30/19 | 0.4751 | 0.5834 | 2 | 0.1420 | 0.0852 | 0.4260 | 0.994 | 571.2 | 882.5 | 28,500 | 30,000 | 0.1411 |
| TBA | DUCK/AW | 605.0 | 54/7 | 0.4747 | 0.5362 | 3 | 0.1058 | 0.1058 | 0.3174 | 0.952 | 569.3 | 745.7 | 21,600 | 22,200 | 0.1454 |
| TBA | KINGBIRD/AW | 636.0 | 18/1 | 0.4997 | 0.5275 | 2 | 0.1880 | 0.1880 | 0.1880 | 0.940 | 596.3 | 675.7 | 15,000 | 15,700 | 0.1408 |
| TBA | SWIFT/AW | 636.0 | 36/1 | 0.4994 | 0.5133 | 3 | 0.1329 | 0.1329 | 0.1329 | 0.930 | 596.0 | 635.7 | 13,600 | 13,800 | 0.1422 |
| TBA | TURACOS/AW | 636.0 | 20/7 | 0.4994 | 0.5339 | 2 | 0.1783 | 0.0792 | 0.2376 | 0.951 | 598.9 | 697.9 | 16,900 | 17,400 | 0.1409 |
| TBA | GOLDFINCH/AW | 636.0 | 22/7 | 0.4994 | 0.5484 | 2 | 0.1700 | 0.0944 | 0.2832 | 0.963 | 598.9 | 739.5 | 19,400 | 19,800 | 0.1396 |
| TBA | ROOK/AW | 636.0 | 24/7 | 0.4996 | 0.5643 | 2 | 0.1628 | 0.1085 | 0.3255 | 0.977 | 599.1 | 784.7 | 22,000 | 22,600 | 0.1381 |
| TBA | GROSBEAK/AW | 636.0 | 26/7 | 0.4995 | 0.5808 | 2 | 0.1564 | 0.1216 | 0.3648 | 0.990 | 599.0 | 832.2 | 24,800 | 25,200 | 0.1367 |
| TBA | SCOTER/AW | 636.0 | 30/7 | 0.4995 | 0.6160 | 2 | 0.1456 | 0.1456 | 0.4368 | 1.019 | 600.5 | 934.7 | 29,300 | 30,400 | 0.1339 |
| TBA | EGRET/AW | 636.0 | 30/19 | 0.4995 | 0.6135 | 2 | 0.1456 | 0.0874 | 0.4370 | 1.019 | 600.5 | 928.2 | 29,900 | 31,500 | 0.1342 |
| TBA | GOOSE/AW | 636.0 | 54/7 | 0.4993 | 0.5640 | 3 | 0.1085 | 0.1085 | 0.3255 | 0.977 | 598.8 | 784.4 | 22,700 | 23,300 | 0.1382 |
| TBA | FLAMINGO/AW | 666.6 | 24/7 | 0.5238 | 0.5917 | 2 | 0.1667 | 0.1111 | 0.3333 | 1.000 | 628.2 | 823.0 | 23,100 | 23,700 | 0.1317 |
| TBA | GANNET/AW | 666.6 | 26/7 | 0.5234 | 0.6086 | 2 | 0.1601 | 0.1245 | 0.3735 | 1.014 | 627.7 | 872.1 | 26,000 | 26,400 | 0.1304 |
| TBA | GULL/AW | 666.6 | 54/7 | 0.5235 | 0.5914 | 3 | 0.1111 | 0.1111 | 0.3333 | 1.000 | 627.8 | 822.6 | 23,500 | 24,200 | 0.1318 |
| TBA | STILT/AW | 715.5 | 24/7 | 0.5622 | 0.6350 | 2 | 0.1727 | 0.1151 | 0.3453 | 1.036 | 674.2 | 883.0 | 24,800 | 25,500 | 0.1227 |
| TBA | STARLING/AW | 715.5 | 26/7 | 0.5620 | 0.6535 | 2 | 0.1659 | 0.1290 | 0.3870 | 1.051 | 674.0 | 936.5 | 27,500 | 28,400 | 0.1215 |
| TBA | REDWING/AW | 715.5 | 30/19 | 0.5617 | 0.6897 | 2 | 0.1544 | 0.0926 | 0.4630 | 1.081 | 675.3 | 1043 | 33,400 | 34,600 | 0.1193 |
| TBA | CROW/AW | 715.5 | 54/7 | 0.5619 | 0.6347 | 3 | 0.1151 | 0.1151 | 0.3453 | 1.036 | 673.9 | 882.7 | 25,300 | 26,000 | 0.1228 |
| TBA | COOT/AW | 795.0 | 36/1 | 0.6244 | 0.6417 | 3 | 0.1486 | 0.1486 | 0.1486 | 1.040 | 745.2 | 794.6 | 16,600 | 16,800 | 0.1137 |
| TBA | TURBIT/AW | 795.0 | 20/7 | 0.6246 | 0.6678 | 2 | 0.1994 | 0.0886 | 0.2658 | 1.063 | 749.1 | 873.0 | 21,200 | 21,800 | 0.1127 |
| TBA | PUFFIN/AW | 795.0 | 22/7 | 0.6244 | 0.6857 | 2 | 0.1901 | 0.1056 | 0.3168 | 1.077 | 748.8 | 924.6 | 24,200 | 24,800 | 0.1116 |
| TBA | CUCKOO/AW | 795.0 | 24/7 | 0.6244 | 0.7053 | 2 | 0.1820 | 0.1213 | 0.3639 | 1.092 | 748.8 | 980.9 | 27,500 | 27,900 | 0.1105 |
| TBA | DRAKE/AW | 795.0 | 26/7 | 0.6247 | 0.7264 | 2 | 0.1749 | 0.1360 | 0.4080 | 1.108 | 749.2 | 1041 | 30,500 | 31,500 | 0.1093 |
| TBA | SKIMMER/AW | 795.0 | 30/7 | 0.6245 | 0.7702 | 2 | 0.1628 | 0.1628 | 0.4884 | 1.140 | 750.8 | 1169 | 35,600 | 37,700 | 0.1071 |
| TBA | MALLARD/AW | 795.0 | 30/19 | 0.6245 | 0.7669 | 2 | 0.1628 | 0.0977 | 0.4885 | 1.140 | 750.8 | 1160 | 37,100 | 38,400 | 0.1073 |
| TBA | TERN/AW | 795.0 | 45/7 | 0.6242 | 0.6674 | 3 | 0.1329 | 0.0886 | 0.2658 | 1.063 | 748.6 | 872.5 | 21,500 | 22,100 | 0.1128 |
| TBA | CONDOR/AW | 795.0 | 54/7 | 0.6240 | 0.7049 | 3 | 0.1213 | 0.1213 | 0.3639 | 1.092 | 748.3 | 980.4 | 27,800 | 28,200 | 0.1106 |
| TBA | RUDDY/AW | 900.0 | 45/7 | 0.7066 | 0.7555 | 3 | 0.1414 | 0.0943 | 0.2829 | 1.131 | 847.4 | 987.7 | 24,000 | 24,400 | 0.0996 |
| TBA | CANARY/AW | 900.0 | 54/7 | 0.7069 | 0.7985 | 3 | 0.1291 | 0.1291 | 0.3873 | 1.162 | 847.7 | 1111 | 31,000 | 31,900 | 0.0976 |
| TBA | CORNCRAKE/AW | 954.0 | 20/7 | 0.7492 | 0.8010 | 2 | 0.2184 | 0.0971 | 0.2913 | 1.165 | 898.5 | 1047 | 25,100 | 25,600 | 0.0939 |
| TBA | REDBIRD/AW | 954.0 | 24/7 | 0.7495 | 0.8466 | 2 | 0.1994 | 0.1329 | 0.3987 | 1.196 | 898.8 | 1177 | 32,600 | 33,500 | 0.0921 |
| TBA | MERGANSER/AW | 954.0 | 30/7 | 0.7491 | 0.9239 | 2 | 0.1783 | 0.1783 | 0.5349 | 1.248 | 900.5 | 1402 | 41,900 | 45,200 | 0.0893 |
| TBA | CANVASBACK/AW | 954.0 | 30/19 | 0.7491 | 0.9199 | 2 | 0.1783 | 0.1070 | 0.5350 | 1.248 | 900.5 | 1391 | 44,500 | 46,100 | 0.0895 |
| TBA | PHOENIX/AW | 954.0 | 42/7 | 0.7491 | 0.7876 | 3 | 0.1507 | 0.0837 | 0.2511 | 1.155 | 898.4 | 1009 | 22,800 | 23,400 | 0.0945 |
| TBA | RAIL/AW | 954.0 | 45/7 | 0.7492 | 0.8010 | 3 | 0.1456 | 0.0971 | 0.2913 | 1.165 | 898.5 | 1047 | 25,400 | 25,900 | 0.0939 |
| TBA | TOWHEE/AW | 954.0 | 48/7 | 0.7495 | 0.8157 | 3 | 0.1410 | 0.1097 | 0.3291 | 1.175 | 898.8 | 1089 | 27,800 | 28,500 | 0.0933 |
| TBA | CARDINAL/AW | 954.0 | 54/7 | 0.7491 | 0.8462 | 3 | 0.1329 | 0.1329 | 0.3987 | 1.196 | 898.4 | 1177 | 32,900 | 33,800 | 0.0921 |
| TBA | SNOWBIRD/AW | 1033.5 | 42/7 | 0.8121 | 0.8539 | 3 | 0.1569 | 0.0872 | 0.2616 | 1.203 | 973.9 | 1094 | 24,800 | 25,400 | 0.0872 |
| TBA | ORTOLAN/AW | 1033.5 | 45/7 | 0.8112 | 0.8673 | 3 | 0.1515 | 0.1010 | 0.3030 | 1.212 | 972.8 | 1134 | 27,100 | 27,700 | 0.0868 |
| TBA | WHOOPER/AW | 1033.5 | 48/7 | 0.8113 | 0.8829 | 3 | 0.1467 | 0.1141 | 0.3423 | 1.223 | 973.0 | 1178 | 30,100 | 30,800 | 0.0862 |
| TBA | CURLEW/AW | 1033.5 | 54/7 | 0.8112 | 0.9164 | 3 | 0.1383 | 0.1383 | 0.4149 | 1.245 | 972.8 | 1275 | 35,100 | 36,600 | 0.0851 |
| TBA | AVOCET/AW | 1113.0 | 42/7 | 0.8743 | 0.9192 | 3 | 0.1628 | 0.0904 | 0.2712 | 1.248 | 1049 | 1178 | 26,600 | 27,100 | 0.0810 |
| TBA | BLUEJAY/AW | 1113.0 | 45/7 | 0.8745 | 0.9350 | 3 | 0.1573 | 0.1049 | 0.3147 | 1.259 | 1049 | 1223 | 29,300 | 29,800 | 0.0805 |
| TBA | BULLFINCH/AW | 1113.0 | 48/7 | 0.8744 | 0.9516 | 3 | 0.1523 | 0.1185 | 0.3555 | 1.269 | 1049 | 1271 | 32,100 | 32,800 | 0.0800 |
| TBA | FINCH/AW | 1113.0 | 54/19 | 0.8746 | 0.9855 | 3 | 0.1436 | 0.0862 | 0.4310 | 1.293 | 1054 | 1373 | 37,500 | 39,100 | 0.0793 |
| TBA | OXBIRD/AW | 1192.5 | 42/7 | 0.9366 | 0.9848 | 3 | 0.1685 | 0.0936 | 0.2808 | 1.292 | 1123 | 1261 | 28,500 | 29,000 | 0.0756 |
| TBA | BUNTING/AW | 1192.5 | 45/7 | 0.9367 | 1.0014 | 3 | 0.1628 | 0.1085 | 0.3255 | 1.302 | 1123 | 1309 | 31,300 | 32,000 | 0.0751 |
| TBA | CORMORANT/AW | 1192.5 | 48/7 | 0.9364 | 1.0190 | 3 | 0.1576 | 0.1226 | 0.3678 | 1.313 | 1123 | 1360 | 34,300 | 34,700 | 0.0747 |
| TBA | GRACKLE/AW | 1192.5 | 54/19 | 0.9365 | 1.0552 | 3 | 0.1486 | 0.0892 | 0.4460 | 1.338 | 1129 | 1470 | 40,200 | 41,900 | 0.0741 |
| TBA | SCISSORTAIL/AW | 1272.0 | 42/7 | 0.9987 | 1.0501 | 3 | 0.1740 | 0.0967 | 0.2901 | 1.334 | 1198 | 1345 | 30,400 | 30,900 | 0.0709 |
| TBA | BITTERN/AW | 1272.0 | 45/7 | 0.9987 | 1.0678 | 3 | 0.1681 | 0.1121 | 0.3363 | 1.345 | 1198 | 1396 | 33,400 | 34,100 | 0.0705 |
| TBA | DIVER/AW | 1272.0 | 48/7 | 0.9992 | 1.0873 | 3 | 0.1628 | 0.1266 | 0.3798 | 1.357 | 1198 | 1451 | 36,600 | 37,000 | 0.0700 |
| TBA | PHEASANT/AW | 1272.0 | 54/19 | 0.9993 | 1.1259 | 3 | 0.1535 | 0.0921 | 0.4605 | 1.382 | 1204 | 1568 | 42,400 | 43,600 | 0.0694 |
| TBA | RINGDOVE/AW | 1351.5 | 42/7 | 1.0617 | 1.1163 | 3 | 0.1794 | 0.0997 | 0.2991 | 1.376 | 1273 | 1430 | 32,400 | 32,900 | 0.0667 |
| TBA | DIPPER/AW | 1351.5 | 45/7 | 1.0614 | 1.1347 | 3 | 0.1733 | 0.1155 | 0.3465 | 1.386 | 1273 | 1483 | 35,500 | 36,200 | 0.0663 |
| TBA | MARTIN/AW | 1351.5 | 54/19 | 1.0614 | 1.1958 | 3 | 0.1582 | 0.0949 | 0.4745 | 1.424 | 1279 | 1665 | 45,100 | 46,300 | 0.0654 |
| TBA | POPINJAY/AW | 1431.0 | 42/7 | 1.1241 | 1.1820 | 3 | 0.1846 | 0.1026 | 0.3078 | 1.415 | 1348 | 1514 | 34,300 | 34,800 | 0.0630 |
| TBA | BOBOLINK/AW | 1431.0 | 45/7 | 1.1236 | 1.2013 | 3 | 0.1783 | 0.1189 | 0.3567 | 1.427 | 1347 | 1570 | 37,600 | 38,300 | 0.0626 |
| TBA | WAGTAIL/AW | 1431.0 | 48/7 | 1.1244 | 1.2236 | 3 | 0.1727 | 0.1343 | 0.4029 | 1.439 | 1348 | 1633 | 40,700 | 41,700 | 0.0622 |
| TBA | PLOVER/AW | 1431.0 | 54/19 | 1.1241 | 1.2665 | 3 | 0.1628 | 0.0977 | 0.4885 | 1.465 | 1355 | 1764 | 47,700 | 49,100 | 0.0617 |
| TBA | NUTHATCH/AW | 1510.5 | 45/7 | 1.1862 | 1.2682 | 3 | 0.1832 | 0.1221 | 0.3663 | 1.466 | 1423 | 1658 | 39,700 | 40,100 | 0.0593 |
| TBA | PARROT/AW | 1510.5 | 54/19 | 1.1856 | 1.3357 | 3 | 0.1672 | 0.1003 | 0.5015 | 1.505 | 1429 | 1860 | 50,300 | 51,700 | 0.0585 |
| TBA | RATITE/AW | 1590.0 | 42/7 | 1.2492 | 1.3134 | 3 | 0.1946 | 0.1081 | 0.3243 | 1.492 | 1498 | 1682 | 38,100 | 38,700 | 0.0567 |
| TBA | LAPWING/AW | 1590.0 | 45/7 | 1.2492 | 1.3355 | 3 | 0.1880 | 0.1253 | 0.3759 | 1.504 | 1498 | 1746 | 41,800 | 42,200 | 0.0563 |
| TBA | HORNBILL/AW | 1590.0 | 48/7 | 1.2487 | 1.3589 | 3 | 0.1820 | 0.1416 | 0.4248 | 1.517 | 1498 | 1814 | 44,700 | 45,300 | 0.0560 |
| TBA | FALCON/AW | 1590.0 | 54/19 | 1.2489 | 1.4072 | 3 | 0.1716 | 0.1030 | 0.5150 | 1.545 | 1505 | 1960 | 53,000 | 54,500 | 0.0556 |
| TBA | CHUKAR/AW | 1780.0 | 84/19 | 1.3986 | 1.5126 | 4 | 0.1456 | 0.0874 | 0.4370 | 1.602 | 1685 | 2013 | 49,400 | 51,000 | 0.0504 |
| TBA | WOODPECKER/AW | 1843.0 | 72/7 | 1.4476 | 1.5102 | 4 | 0.1600 | 0.1067 | 0.3201 | 1.600 | 1745 | 1925 | 41,800 | 42,400 | 0.0493 |
| TBA | SEAHAWK/AW | 1869.0 | 68/7 | 1.4681 | 1.5147 | 4 | 0.1658 | 0.0921 | 0.2763 | 1.603 | 1769 | 1903 | 39,500 | 40,000 | 0.0488 |
| TBA | MOCKINGBIRD/AW | 2034.5 | 72/7 | 1.5979 | 1.6670 | 4 | 0.1681 | 0.1121 | 0.3363 | 1.681 | 1926 | 2124 | 46,100 | 46,800 | 0.0446 |
| TBA | BLUEBIRD/AW | 2156.0 | 84/19 | 1.6931 | 1.8309 | 4 | 0.1602 | 0.0961 | 0.4805 | 1.762 | 2040 | 2436 | 59,000 | 60,300 | 0.0416 |
| TBA | KIWI/AW | 2167.0 | 72/7 | 1.7022 | 1.7758 | 4 | 0.1735 | 0.1157 | 0.3471 | 1.735 | 2051 | 2262 | 49,100 | 49,800 | 0.0419 |
| TBA | THRASHER/AW | 2312.0 | 76/19 | 1.8155 | 1.9144 | 4 | 0.1744 | 0.0814 | 0.4070 | 1.802 | 2188 | 2472 | 55,300 | 56,700 | 0.0391 |
| TBA | JOREE/AW | 2515.0 | 76/19 | 1.9750 | 2.0826 | 4 | 0.1819 | 0.0849 | 0.4245 | 1.880 | 2380 | 2689 | 60,200 | 61,700 | 0.0360 |
Revision: 1.000.010
Updated On: Nov. 20, 2026, 10:35 p.m. UTC
