SPEC 42036

PFA 250°C 600V UL 1727

Flexible UL/CSA Approved Lead Wire, Temp Rating 250°C

...

Construction:

  1. Conductor:Stranded annealed nickel plated copper
  2. Insulation:Extruded PFA fluoropolymer

Applications and Features:

Used for wiring of electric heaters, appliances, thermocouples, gas igniters, electrical and electronic components and other products that require a temperature rating up to 250° C.

Excellent chemical resistance, excellent resistance to fluids, and low coefficient of friction makes installation easier. Flexible. Good mechanical strength. Available in all colors.

Specifications:

  • UL AWM Appliance wire approvals as listed in Table 1
  • CSA AWM I A/B FT1
  • RoHS-3 Complies with European Directive 2015/863
  • Table 1 – Weights and Measurements
    Stock NumberCond. SizeCond. StrandsInsul. ThicknessApprox. ODApprox. WeightTemp. RatingStandard (UL or other)
    AWG/Kcmilstrandmilinchlb/1000ft°CStyle/Type
    CP246A247200.05542501727
    CP226A2210200.07052501727
    CP206A2019200.08072501727
    CP186A1819200.090102501727
    CP166A1619200.100132501727
    CP146A1419200.110172501727
    CP126A1219200.130252501727
    CP106A1037200.145352501727
    CP086A8133300.230702501727
    CP066A6133300.2701052501727
    CP046A4133300.3251602501727
    CP026A2133300.3952352501727
    CP016A1259450.4703202501727
    CP1T6A1/0259450.5154002501727
    CP2T6A2/0259450.5704952501727
    CP3T6A3/0259450.6105652501727
    CP4T6A4/0259450.6907302501727
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item
    Dimensions and weights for other cable configurations are available upon request.
    Table 2 – Weights and Measurements (Metric)
    Stock NumberCond. SizeCond. StrandsInsul. ThicknessApprox. ODApprox. WeightTemp. RatingStandard (UL or other)
    AWG/Kcmilstrandmmmmkg/km°CStyle/Type
    CP246A2470.511.4062501727
    CP226A22100.511.7872501727
    CP206A20190.512.03102501727
    CP186A18190.512.29152501727
    CP166A16190.512.54192501727
    CP146A14190.512.79252501727
    CP126A12190.513.30372501727
    CP106A10370.513.68522501727
    CP086A81330.765.841042501727
    CP066A61330.766.861562501727
    CP046A41330.768.252382501727
    CP026A21330.7610.033502501727
    CP016A12591.1411.944762501727
    CP1T6A1/02591.1413.085952501727
    CP2T6A2/02591.1414.487372501727
    CP3T6A3/02591.1415.498412501727
    CP4T6A4/02591.1417.5310862501727

    Revision: 1.000.001

    Updated On: July 3, 2024, 10:13 p.m. UTC