SPEC 42035

PFA 250°C 300V UL 1726

Flexible UL/CSA Approved Lead Wire, Temp Rating 250°C

...

Construction:

  1. Conductor:Stranded annealed nickel plated copper
  2. Insulation:Extruded PFA fluoropolymer

Applications and Features:

Used for wiring of electric heaters, appliances, thermocouples, gas igniters, electrical and electronic components and other products that require a temperature rating up to 250° C.

Excellent chemical resistance, excellent resistance to fluids, and low coefficient of friction makes installation easier. Flexible. Good mechanical strength. Available in all colors.

Specifications:

  • UL AWM Appliance wire approvals as listed in Table 1
  • CSA AWM I A/B FT1
  • RoHS-3 Complies with European Directive 2015/863
  • Table 1 – Weights and Measurements
    Stock NumberCond. SizeCond. StrandsInsul. ThicknessApprox. ODApprox. WeightTemp. RatingStandard (UL or other)
    AWG/Kcmilstrandmilinchlb/1000ft°CStyle/Type
    CP243A247130.05042501726
    CP223A2210130.05552501726
    CP203A2019130.06572501726
    CP183A1819130.075102501726
    CP163A1619130.085132501726
    CP143A1419130.110162501726
    CP123A1219130.115222501726
    CP103A1037130.145322501726
    CP083A8133200.210642501726
    CP063A6133200.250972501726
    CP043A4133300.3251602501726
    CP023A2133300.3952352501726
    CP013A1259450.4703202501726
    CPIT3A1/0259450.5154002501726
    CPT23A2/0259450.5704952501726
    CP3T3A3/0259450.6105652501726
    CP4T3A4/0259450.6907302501726
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item
    Dimensions and weights for other cable configurations are available upon request.
    Table 2 – Weights and Measurements (Metric)
    Stock NumberCond. SizeCond. StrandsInsul. ThicknessApprox. ODApprox. WeightTemp. RatingStandard (UL or other)
    AWG/Kcmilstrandmmmmkg/km°CStyle/Type
    CP243A2470.331.2762501726
    CP223A22100.331.4072501726
    CP203A20190.331.65102501726
    CP183A18190.331.90152501726
    CP163A16190.332.16192501726
    CP143A14190.332.79242501726
    CP123A12190.332.92332501726
    CP103A10370.333.68482501726
    CP083A81330.515.33952501726
    CP063A61330.516.351442501726
    CP043A41330.768.252382501726
    CP023A21330.7610.033502501726
    CP013A12591.1411.944762501726
    CPIT3A1/02591.1413.085952501726
    CPT23A2/02591.1414.487372501726
    CP3T3A3/02591.1415.498412501726
    CP4T3A4/02591.1417.5310862501726

    Revision: 1.000.001

    Updated On: July 3, 2024, 10:13 p.m. UTC