SPEC 42022

FEP 200°C 600V UL 1330

Flexible UL/CSA Approved Lead Wire, Temp Rating 200°C

...

Construction:

  1. Conductor:Stranded tinned, annealed copper per ASTM B33
  2. Insulation:Extruded FEP fluoropolymer

Applications and Features:

Used for wiring of electric heaters, appliances, thermocouples, gas igniters, electrical and electronic components, and other products that require a temperature rating up to 200° C.

Excellent chemical resistance, excellent resistance to fluids, and low coefficient of friction makes installation easier. Flexible. Good mechanical strength. Available in all colors.

Specifications:

  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • UL AWM Appliance wire approvals as listed in Table 1
  • CSA AWM I A/B 600 FT1 FT2
  • RoHS-3 Complies with European Directive 2015/863
  • Table 1 – Weights and Measurements
    Stock NumberCond. SizeCond. StrandsInsul. ThicknessApprox. ODApprox. WeightTemp. RatingStandard (UL or other)
    AWG/Kcmilstrandmilinchlb/1000ft°CStyle/Type
    C3246Z*24*7200.06542001330
    C3226Z*22*7200.07052001330
    C3206Z*20*7200.08072001330
    C3186A187200.090102001330
    C3166A167200.100132001330
    C3146A147200.110172001330
    C3126A1219200.130252001330
    C3106A1037200.160352001330
    C3086A854300.220602001330
    C3066A684300.235952001330
    C3046A4133300.2951452001330
    C3026A2133300.3402202001330
    C3016A1259450.4603202001330
    C31T6A1/0259450.4853602001330
    C32T6A2/0259450.5154602001330
    C33T6A3/0259450.5755652001330
    C34T6A4/0259450.6757552001330
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item
    Dimensions and weights for other cable configurations are available upon request.
    *NPC Conductor required for 200°C Rating
    Table 2 – Weights and Measurements (Metric)
    Stock NumberCond. SizeCond. StrandsInsul. ThicknessApprox. ODApprox. WeightTemp. RatingStandard (UL or other)
    AWG/Kcmilstrandmmmmkg/km°CStyle/Type
    C3246Z*24*70.511.6562001330
    C3226Z*22*70.511.7872001330
    C3206Z*20*70.512.03102001330
    C3186A1870.512.29152001330
    C3166A1670.512.54192001330
    C3146A1470.512.79252001330
    C3126A12190.513.30372001330
    C3106A10370.514.06522001330
    C3086A8540.765.59892001330
    C3066A6840.765.971412001330
    C3046A41330.767.492162001330
    C3026A21330.768.643272001330
    C3016A12591.1411.684762001330
    C31T6A1/02591.1412.325362001330
    C32T6A2/02591.1413.086852001330
    C33T6A3/02591.1414.608412001330
    C34T6A4/02591.1417.1511242001330

    Revision: 1.000.000