SPEC 53018

Flexible Hook-Up Wire/Appliance Wire Styles 3499

150°C 7500 Volts. Flexible Stranded Tinned Copper Conductor. EPDM Insulation.

...

Construction:

  1. Conductor:Flexible stranded tinned copper. Bare copper available upon request
  2. Conductor Separator:Mylar
  3. Insulation:Black, Ethylene Propylene Diene Monomer (EPDM)

Applications and Features:

Designed for Internal Wiring Appliances, where no flexing occurs, either after installation or during servicing.

  • AWM Style 3499: 150°C/7500V
  • Specifications:

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • ASTM B173 Rope-Lay-Stranded Copper Conductors Having Concentric-Stranded Members
  • ASTM B174 Standard Specification for Bunch-Stranded Copper
  • UL 758 Standard for Appliance Wiring Material
  • Sample Print Legend:

    XX AWG (XX.XXmm2) E57498 MASTER-DESIGN (RU) AWM 3499 150C 7500V -- MADE IN USA
    Table 1 – Physical and Electrical Data
    Stock NumberCond. SizeCond. NumberCond. StrandsDiameter Over Cond.Insul. ThicknessApprox. ODApprox. WeightDC Resistance @ 25°CAC Resistance @ 75°C
    AWGNo.strandsinchmilinchlb/1000ftΩ/1000ftΩ/1000ft
    AWM
    F0607661840.1801300.4731680.4350.524
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item

    Revision: 1.000.005

    Updated On: June 23, 2025, 11:44 a.m. UTC

    Ampacity
    QR Code