SPEC 80116
ACSS/TW/HS285®
Aluminum Conductor, Ultra-High-Strength Steel Supported, Trapezoidal Wire

Construction:
- Core: Stranded ultra-high-strength HS285® steel core with zinc-5% aluminum-mischmetal alloy coating for corrosion protection
- Stranding: Annealed aluminum (1350-O) trapezoidal-shaped wires with 63% conductivity
Applications and Features:
ACSS/TW/HS285® (Aluminum Conductor, Ultra-High-Strength Steel Supported, Trapezoidal Wire) combines a compact trapezoidal-wire aluminum construction with Southwire’s ultra-high-strength HS285 steel core. The annealed aluminum provides electrical conductivity, while the HS285 core carries the mechanical load and provides maximum strength for demanding transmission applications.
The trapezoidal-wire design allows additional aluminum area within a specified conductor diameter or a reduced diameter for a specified aluminum area. Area-equivalent and diameter-equivalent designs provide flexibility when balancing ampacity, resistance, weight, diameter, wind loading, ice loading, and existing structure requirements.
ACSS/TW/HS285 is particularly well suited for high-capacity reconductoring, long spans, river crossings, heavily loaded lines, and projects where improved electrical performance and maximum mechanical strength are required within existing clearance or tension limits.
Southwire batch anneals the completed conductor after stranding, allowing the aluminum to be fully annealed while supporting tighter stranding and verification of finished conductor properties after heat exposure.
HS285 steel-core tensile properties are verified after heat exposure to account for the effects of ACSS manufacturing and high-temperature operation.
Continuous operating temperature - 250°C
The trapezoidal-wire design allows additional aluminum area within a specified conductor diameter or a reduced diameter for a specified aluminum area. Area-equivalent and diameter-equivalent designs provide flexibility when balancing ampacity, resistance, weight, diameter, wind loading, ice loading, and existing structure requirements.
ACSS/TW/HS285 is particularly well suited for high-capacity reconductoring, long spans, river crossings, heavily loaded lines, and projects where improved electrical performance and maximum mechanical strength are required within existing clearance or tension limits.
Southwire batch anneals the completed conductor after stranding, allowing the aluminum to be fully annealed while supporting tighter stranding and verification of finished conductor properties after heat exposure.
HS285 steel-core tensile properties are verified after heat exposure to account for the effects of ACSS manufacturing and high-temperature operation.
Continuous operating temperature - 250°C
Specifications:
Resources:
Area Equal to Standard ACSR Conductor - Weights, Measurements, Electrical and Engineering Data
| Stock Number | Code Word | Conductor Size | Type No. | Stranding | Cross-Sectional Area | Layers of Al | Diameter | Weight | Rated Breaking Strength | DC Resistance @ 20°C | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Steel Strand | Steel Core | Complete Conductor | ||||||||||||
| Al | Total | Al | Total | |||||||||||
| kcmil | Al/St | in² | in² | in | in | in | lb/1000ft | lb/1000ft | lb | Ω/mile | ||||
| TBA | PARTRIDGE/ACSS/TW | 266.8 | 16 | 14/7 | 0.2095 | 0.2436 | 2 | 0.0788 | 0.2364 | 0.595 | 250.6 | 366 | 11,400 | 0.3263 |
| TBA | LINNET/ACSS/TW | 336.4 | 16 | 16/7 | 0.2642 | 0.3072 | 2 | 0.0884 | 0.2652 | 0.659 | 316.1 | 461.7 | 14,400 | 0.2588 |
| TBA | ORIOLE/ACSS/TW | 336.4 | 23 | 16/7 | 0.2642 | 0.3259 | 2 | 0.1059 | 0.3177 | 0.692 | 317.6 | 526.5 | 19,100 | 0.2577 |
| TBA | IBIS/ACSS/TW | 397.5 | 16 | 20/7 | 0.3122 | 0.363 | 2 | 0.0961 | 0.2883 | 0.725 | 373.5 | 545.5 | 16,500 | 0.219 |
| TBA | LARK/ACSS/TW | 397.5 | 23 | 16/7 | 0.3122 | 0.385 | 2 | 0.1151 | 0.3453 | 0.74 | 375.3 | 621.8 | 22,600 | 0.2181 |
| TBA | FLICKER/ACSS/TW | 477 | 13 | 18/7 | 0.3746 | 0.4232 | 2 | 0.094 | 0.282 | 0.776 | 447.7 | 612.2 | 16,400 | 0.1831 |
| TBA | HAWK/ACSS/TW | 477 | 16 | 18/7 | 0.3746 | 0.4356 | 2 | 0.1053 | 0.3159 | 0.79 | 448.1 | 654.6 | 19,800 | 0.1825 |
| TBA | HEN/ACSS/TW | 477 | 23 | 20/7 | 0.3746 | 0.462 | 2 | 0.1261 | 0.3783 | 0.82 | 450.3 | 746.2 | 26,700 | 0.1817 |
| TBA | PARAKEET/ACSS/TW | 556.5 | 13 | 18/7 | 0.4371 | 0.4937 | 2 | 0.1015 | 0.3045 | 0.84 | 522.4 | 714 | 19,100 | 0.1569 |
| TBA | DOVE/ACSS/TW | 556.5 | 16 | 20/7 | 0.4371 | 0.5083 | 2 | 0.1138 | 0.3414 | 0.85 | 522.9 | 763.9 | 23,100 | 0.1564 |
| TBA | EAGLE/ACSS/TW | 556.5 | 23 | 20/7 | 0.4371 | 0.5391 | 2 | 0.1362 | 0.4086 | 0.87 | 525.5 | 870.8 | 31,100 | 0.1558 |
| TBA | SQUAB/ACSS/TW | 605 | 16 | 20/7 | 0.4752 | 0.5525 | 2 | 0.1186 | 0.3558 | 0.885 | 568.5 | 830.2 | 25,100 | 0.1439 |
| TBA | TEAL/ACSS/TW | 605 | 23 | 20/19 | 0.4752 | 0.5835 | 2 | 0.0852 | 0.426 | 0.916 | 571.3 | 938.7 | 34,700 | 0.1434 |
| TBA | ROOK/ACSS/TW | 636 | 13 | 20/7 | 0.4995 | 0.5642 | 2 | 0.1085 | 0.3255 | 0.893 | 597 | 816 | 21,900 | 0.1373 |
| TBA | GROSBEAK/ACSS/TW | 636 | 16 | 20/7 | 0.4995 | 0.5808 | 2 | 0.1216 | 0.3648 | 0.909 | 597.6 | 872.8 | 26,000 | 0.1369 |
| TBA | SCOTER/ACSS/TW | 636 | 23 | 22/7 | 0.4995 | 0.616 | 2 | 0.1456 | 0.4368 | 0.942 | 600.5 | 994.9 | 35,000 | 0.1363 |
| TBA | EGRET/ACSS/TW | 636 | 23 | 22/19 | 0.4995 | 0.6135 | 2 | 0.0874 | 0.437 | 0.942 | 600.5 | 987.2 | 36,600 | 0.1364 |
| TBA | STARLING/ACSS/TW | 715.5 | 16 | 20/7 | 0.562 | 0.6535 | 2 | 0.129 | 0.387 | 0.958 | 672.3 | 982.1 | 29,300 | 0.1216 |
| TBA | REDWING/ACSS/TW | 715.5 | 23 | 20/19 | 0.562 | 0.69 | 2 | 0.0926 | 0.463 | 0.994 | 675.6 | 1110 | 39,800 | 0.1212 |
| TBA | TERN/ACSS/TW | 795 | 7 | 20/7 | 0.6244 | 0.6676 | 2 | 0.0886 | 0.2658 | 0.96 | 745.2 | 891.5 | 17,400 | 0.1105 |
| TBA | PUFFIN/ACSS/TW | 795 | 10 | 18/7 | 0.6244 | 0.6857 | 2 | 0.1056 | 0.3168 | 0.98 | 745.9 | 953.4 | 22,000 | 0.1102 |
| TBA | CONDOR/ACSS/TW | 795 | 13 | 20/7 | 0.6244 | 0.7053 | 2 | 0.1213 | 0.3639 | 0.993 | 746.3 | 1020 | 26,900 | 0.1098 |
| TBA | DRAKE/ACSS/TW | 795 | 16 | 20/7 | 0.6244 | 0.7261 | 2 | 0.136 | 0.408 | 1.01 | 747 | 1091 | 32,600 | 0.1095 |
| TBA | MALLARD/ACSS/TW | 795 | 23 | 22/19 | 0.6244 | 0.7668 | 2 | 0.0977 | 0.4885 | 1.05 | 750.6 | 1234 | 44,300 | 0.1091 |
| TBA | CANARY/ACSS/TW | 900 | 13 | 20/7 | 0.7069 | 0.7985 | 2 | 0.1291 | 0.3873 | 1.055 | 844.9 | 1155 | 30,500 | 0.097 |
| TBA | PHOENIX/ACSS/TW | 954 | 5 | 30/7 | 0.7493 | 0.7878 | 3 | 0.0837 | 0.2511 | 1.044 | 897.7 | 1028 | 17,100 | 0.0927 |
| TBA | RAIL/ACSS/TW | 954 | 7 | 32/7 | 0.7493 | 0.8011 | 3 | 0.0971 | 0.2913 | 1.061 | 898.6 | 1074 | 20,400 | 0.0926 |
| TBA | CARDINAL/ACSS/TW | 954 | 13 | 20/7 | 0.7493 | 0.8464 | 2 | 0.1329 | 0.3987 | 1.08 | 895.5 | 1224 | 32,300 | 0.0915 |
| TBA | CANVASBACK/ACSS/TW | 954 | 23 | 24/19 | 0.7493 | 0.9201 | 2 | 0.107 | 0.535 | 1.149 | 900.8 | 1480 | 53,100 | 0.0909 |
| TBA | SNOWBIRD/ACSS/TW | 1033.5 | 5 | 30/7 | 0.8117 | 0.8535 | 3 | 0.0872 | 0.2616 | 1.089 | 972.5 | 1114 | 18,500 | 0.0856 |
| TBA | ORTOLAN/ACSS/TW | 1033.5 | 7 | 34/7 | 0.8117 | 0.8678 | 3 | 0.101 | 0.303 | 1.102 | 973.4 | 1163 | 22,000 | 0.0854 |
| TBA | CURLEW/ACSS/TW | 1033.5 | 13 | 22/7 | 0.8117 | 0.9169 | 2 | 0.1383 | 0.4149 | 1.131 | 970.1 | 1326 | 35,000 | 0.0845 |
| TBA | AVOCET/ACSS/TW | 1113 | 5 | 30/7 | 0.8741 | 0.919 | 3 | 0.0904 | 0.2712 | 1.13 | 1047 | 1199 | 19,500 | 0.0794 |
| TBA | BLUEJAY/ACSS/TW | 1113 | 7 | 34/7 | 0.8741 | 0.9346 | 3 | 0.1049 | 0.3147 | 1.143 | 1048 | 1253 | 23,800 | 0.0793 |
| TBA | FINCH/ACSS/TW | 1113 | 13 | 38/19 | 0.8741 | 0.985 | 3 | 0.0862 | 0.431 | 1.19 | 1051 | 1427 | 38,700 | 0.0789 |
| TBA | OXBIRD/ACSS/TW | 1192.5 | 5 | 30/7 | 0.9366 | 0.9848 | 3 | 0.0936 | 0.2808 | 1.17 | 1122 | 1285 | 20,900 | 0.0741 |
| TBA | BUNTING/ACSS/TW | 1192.5 | 7 | 34/7 | 0.9366 | 1.0013 | 3 | 0.1085 | 0.3255 | 1.181 | 1123 | 1342 | 25,400 | 0.074 |
| TBA | GRACKLE/ACSS/TW | 1192.5 | 13 | 38/19 | 0.9366 | 1.0553 | 3 | 0.0892 | 0.446 | 1.225 | 1126 | 1529 | 41,500 | 0.0737 |
| TBA | SCISSORTAIL/ACSS/TW | 1272 | 5 | 30/7 | 0.999 | 1.0504 | 3 | 0.0967 | 0.2901 | 1.203 | 1197 | 1371 | 22,300 | 0.0695 |
| TBA | BITTERN/ACSS/TW | 1272 | 7 | 38/7 | 0.999 | 1.0681 | 3 | 0.1121 | 0.3363 | 1.224 | 1198 | 1432 | 27,200 | 0.0694 |
| TBA | PHEASANT/ACSS/TW | 1272 | 13 | 39/19 | 0.999 | 1.1256 | 3 | 0.0921 | 0.4605 | 1.26 | 1201 | 1631 | 43,000 | 0.0691 |
| TBA | DIPPER/ACSS/TW | 1351.5 | 7 | 36/7 | 1.0615 | 1.1348 | 3 | 0.1155 | 0.3465 | 1.256 | 1273 | 1521 | 28,800 | 0.0653 |
| TBA | MARTIN/ACSS/TW | 1351.5 | 13 | 42/19 | 1.0615 | 1.1959 | 3 | 0.0949 | 0.4745 | 1.3 | 1276 | 1732 | 45,600 | 0.065 |
| TBA | BOBOLINK/ACSS/TW | 1431 | 7 | 36/7 | 1.1239 | 1.2016 | 3 | 0.1189 | 0.3567 | 1.29 | 1348 | 1611 | 30,500 | 0.0617 |
| TBA | PLOVER/ACSS/TW | 1431 | 13 | 44/19 | 1.1239 | 1.2663 | 3 | 0.0977 | 0.4885 | 1.337 | 1351 | 1834 | 48,300 | 0.0614 |
| TBA | LAPWING/ACSS/TW | 1590 | 7 | 36/7 | 1.2488 | 1.3351 | 3 | 0.1253 | 0.3759 | 1.358 | 1498 | 1790 | 33,500 | 0.0555 |
| TBA | FALCON/ACSS/TW | 1590 | 13 | 42/19 | 1.2488 | 1.4071 | 3 | 0.103 | 0.515 | 1.41 | 1501 | 2038 | 53,700 | 0.0553 |
| TBA | CHUKAR/ACSS/TW | 1780 | 8 | 38/19 | 1.398 | 1.512 | 3 | 0.0874 | 0.437 | 1.445 | 1674 | 2061 | 43,900 | 0.0495 |
| TBA | BLUEBIRD/ACSS/TW | 2156 | 8 | 64/19 | 1.6933 | 1.8311 | 4 | 0.0961 | 0.4805 | 1.608 | 2045 | 2512 | 51,700 | 0.0412 |
Diameter Equal to Standard ACSR Conductor - Weights, Measurements, Electrical and Engineering Data
| Stock Number | Code Word | Conductor Size | Type No. | Stranding | ACSR with Equal Diameter | Cross-Sectional Area | Layers of Al | Diameter | Weight | Rated Breaking Strength | DC Resistance @ 20°C | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Steel Strand | Steel Core | Complete Conductor | |||||||||||||||
| Code Word | Size | Stranding | Al | Total | Al | Total | |||||||||||
| kcmil | Al/St | kcmil | Al/St | in² | in² | in | in | in | lb/1000ft | lb/1000ft | lb | Ω/mile | |||||
| TBA | CALUMET/ACSS/TW | 565.3 | 16 | 20/7 | Hawk | 477 | 26/7 | 0.444 | 0.5162 | 2 | 0.1146 | 0.3438 | 0.86 | 531.2 | 775.6 | 23,500 | 0.154 |
| TBA | MOHAWK/ACSS/TW | 571.7 | 13 | 18/7 | Flicker | 477 | 24/7 | 0.449 | 0.5073 | 2 | 0.103 | 0.309 | 0.85 | 536.6 | 734 | 19,700 | 0.1527 |
| TBA | OSWEGO/ACSS/TW | 664.8 | 16 | 20/7 | Dove | 556.5 | 26/7 | 0.5221 | 0.6072 | 2 | 0.1244 | 0.3732 | 0.927 | 624.6 | 912.7 | 27,200 | 0.1309 |
| TBA | MYSTIC/ACSS/TW | 666.6 | 13 | 20/7 | Parakeet | 556.5 | 24/7 | 0.5235 | 0.5914 | 2 | 0.1111 | 0.3333 | 0.913 | 625.7 | 855.6 | 22,900 | 0.131 |
| TBA | WABASH/ACSS/TW | 762.8 | 16 | 20/7 | Grosbeak | 636 | 26/7 | 0.5991 | 0.6965 | 2 | 0.1331 | 0.3993 | 0.99 | 716.7 | 1046 | 31,200 | 0.1141 |
| TBA | MAUMEE/ACSS/TW | 768.2 | 13 | 20/7 | Rook | 636 | 24/7 | 0.6033 | 0.6818 | 2 | 0.1195 | 0.3585 | 0.977 | 721 | 986.8 | 26,500 | 0.1137 |
| TBA | FRASER/ACSS/TW | 946.7 | 10 | 34/7 | Puffin | 795 | 22/7 | 0.7435 | 0.8167 | 3 | 0.1154 | 0.3462 | 1.077 | 892.5 | 1140 | 26,200 | 0.093 |
| TBA | KETTLE/ACSS/TW | 957.2 | 7 | 32/7 | Tern | 795 | 45/7 | 0.7518 | 0.8038 | 3 | 0.0973 | 0.2919 | 1.06 | 901.6 | 1078 | 20,400 | 0.0922 |
| TBA | SUWANNEE/ACSS/TW | 959.6 | 16 | 22/7 | Drake | 795 | 26/7 | 0.7537 | 0.8762 | 2 | 0.1493 | 0.4479 | 1.11 | 901.7 | 1316 | 38,600 | 0.0907 |
| TBA | COLUMBIA/ACSS/TW | 966.2 | 13 | 22/7 | Condor | 795 | 54/7 | 0.7589 | 0.8573 | 2 | 0.1338 | 0.4014 | 1.092 | 907 | 1240 | 32,800 | 0.0904 |
| TBA | GENESEE/ACSS/TW | 1158 | 7 | 34/7 | Rail | 954 | 45/7 | 0.9095 | 0.9734 | 3 | 0.1078 | 0.3234 | 1.165 | 1091 | 1307 | 25,000 | 0.0762 |
| TBA | HUDSON/ACSS/TW | 1158.4 | 13 | 24/7 | Cardinal | 954 | 54/7 | 0.9098 | 1.0281 | 2 | 0.1467 | 0.4401 | 1.196 | 1087 | 1488 | 38,800 | 0.0754 |
| TBA | CHEYENNE/ACSS/TW | 1168.1 | 5 | 30/7 | Phoenix | 954 | 42/7 | 0.9174 | 0.9645 | 3 | 0.0926 | 0.2778 | 1.155 | 1099 | 1259 | 20,500 | 0.0757 |
| TBA | YUKON/ACSS/TW | 1233.6 | 13 | 38/19 | Curlew | 1033.5 | 54/7 | 0.9689 | 1.0925 | 3 | 0.091 | 0.455 | 1.245 | 1165 | 1584 | 41,900 | 0.0712 |
| TBA | NELSON/ACSS/TW | 1257.1 | 7 | 36/7 | Ortolan | 1033.5 | 45/7 | 0.9873 | 1.0556 | 3 | 0.1115 | 0.3345 | 1.213 | 1184 | 1415 | 26,900 | 0.0702 |
| TBA | CATAWBA/ACSS/TW | 1272 | 5 | 30/7 | Snowbird | 1033.5 | 42/7 | 0.999 | 1.0504 | 3 | 0.0967 | 0.2901 | 1.203 | 1197 | 1371 | 22,300 | 0.0695 |
| TBA | THAMES/ACSS/TW | 1334.6 | 13 | 38/19 | Finch | 1113 | 54/19 | 1.0482 | 1.1812 | 3 | 0.0944 | 0.472 | 1.29 | 1260 | 1711 | 45,100 | 0.0658 |
| TBA | MACKENZIE/ACSS/TW | 1359.7 | 7 | 38/7 | Bluejay | 1113 | 45/7 | 1.0679 | 1.1418 | 3 | 0.1159 | 0.3477 | 1.26 | 1281 | 1531 | 29,000 | 0.0649 |
| TBA | TRUCKEE/ACSS/TW | 1372.5 | 5 | 30/7 | Avocet | 1113 | 42/7 | 1.078 | 1.1334 | 3 | 0.1004 | 0.3012 | 1.248 | 1292 | 1480 | 24,000 | 0.0644 |
| TBA | MERRIMACK/ACSS/TW | 1433.6 | 13 | 39/19 | Grackle | 1192.5 | 54/19 | 1.1259 | 1.2686 | 3 | 0.0978 | 0.489 | 1.34 | 1354 | 1838 | 48,400 | 0.0613 |
| TBA | MIRAMICHI/ACSS/TW | 1455.3 | 7 | 36/7 | Bunting | 1192.5 | 45/7 | 1.143 | 1.2222 | 3 | 0.12 | 0.36 | 1.302 | 1371 | 1639 | 30,700 | 0.0607 |
| TBA | ST. CROIX/ACSS/TW | 1467.8 | 5 | 33/7 | Oxbird | 1192.5 | 42/7 | 1.1528 | 1.2124 | 3 | 0.1041 | 0.3123 | 1.292 | 1381 | 1583 | 25,800 | 0.0602 |
| TBA | RIO GRANDE/ACSS/TW | 1533.3 | 13 | 38/19 | Pheasant | 1272 | 54/19 | 1.2043 | 1.3571 | 3 | 0.1012 | 0.506 | 1.38 | 1448 | 1966 | 51,900 | 0.0573 |
| TBA | POTOMAC/ACSS/TW | 1557.4 | 7 | 36/7 | Bittern | 1272 | 45/7 | 1.2232 | 1.3079 | 3 | 0.1241 | 0.3723 | 1.35 | 1467 | 1754 | 32,800 | 0.0567 |
| TBA | PLATTE/ACSS/TW | 1569 | 5 | 33/7 | Scissortail | 1272 | 42/7 | 1.2323 | 1.2957 | 3 | 0.1074 | 0.3222 | 1.334 | 1476 | 1691 | 27,500 | 0.0564 |
| TBA | PECOS/ACSS/TW | 1622 | 13 | 39/19 | Martin | 1351.5 | 54/19 | 1.2739 | 1.4428 | 3 | 0.1064 | 0.532 | 1.42 | 1531 | 2104 | 56,900 | 0.0541 |
| TBA | SCHUYLKILL/ACSS/TW | 1657.4 | 7 | 36/7 | Dipper | 1351.5 | 45/7 | 1.3017 | 1.3918 | 3 | 0.128 | 0.384 | 1.386 | 1561 | 1866 | 34,900 | 0.0533 |
| TBA | JAMES/ACSS/TW | 1730.6 | 13 | 39/19 | Plover | 1431 | 54/19 | 1.3592 | 1.5316 | 3 | 0.1075 | 0.5375 | 1.47 | 1634 | 2219 | 58,500 | 0.0508 |
| TBA | PEE DEE/ACSS/TW | 1758.6 | 7 | 38/7 | Bobolink | 1431 | 45/7 | 1.3812 | 1.4768 | 3 | 0.1319 | 0.3957 | 1.43 | 1656 | 1980 | 37,100 | 0.0502 |
| TBA | CUMBERLAND/ACSS/TW | 1926.9 | 13 | 42/19 | Falcon | 1590 | 54/19 | 1.5134 | 1.705 | 3 | 0.1133 | 0.5665 | 1.55 | 1819 | 2469 | 65,000 | 0.0456 |
| TBA | ATHABASKA/ACSS/TW | 1949.6 | 7 | 44/7 | Lapwing | 1590 | 45/7 | 1.5312 | 1.6377 | 3 | 0.1392 | 0.4176 | 1.504 | 1836 | 2197 | 41,300 | 0.0453 |
| TBA | POWDER/ACSS/TW | 2153.8 | 8 | 64/19 | Chukar | 1780 | 84/19 | 1.6916 | 1.8294 | 4 | 0.0961 | 0.4805 | 1.596 | 2043 | 2510 | 51,700 | 0.0412 |
| TBA | SANTEE/ACSS/TW | 2627.3 | 8 | 64/19 | Bluebird | 2156 | 84/19 | 2.0635 | 2.2318 | 4 | 0.1062 | 0.531 | 1.761 | 2492 | 3063 | 63,100 | 0.0338 |
Revision: 1.000.024
Updated On: Nov. 20, 2026, 11:58 p.m. UTC

