SPEC 22050

NMD90 Copper SIMpull® Romex® Brand

300 Volts / -25ºC Min, 90ºC Max. Copper Conductors

...

Construction:

  1. Conductor:Bare copper per ASTM B3. Sizes #14 AWG - #10 AWG are solid. Sizes #8 AWG - #2 AWG are Class B compressed stranded per ASTM B8
  2. Insulation:All phases are insulated with Polyvinyl Chloride (PVC) with Nylon Sheath
  3. Jacket:Polyvinyl Chloride (PVC) jacket utilizing SIMpull® Technology.

Conductor Color Color Code:
  • 2/C: Black, White
  • 3/C: Black, White, Red

  • Jacket Color Color Code:
  • White: General Residential Wiring
  • Red: 2 Black and Red conductors - 208V-240V Circuits (no neutral)
  • Orange: No. 10 AWG General Residential Wiring
  • Yellow: No. 12 AWG General Residential Wiring
  • Blue: No. 14 AWG - 2 black and white conductors - 120V Arc Fault Circuit Interupter Applications
  • Applications and Features:

    Southwire's Romex® SIMpull® NMD90 cables may be used for both exposed work in dry locations or concealed work in dry or damp locations.
    The maximum allowable conductor temperature is 90°C. The minimum recommended installation temperature is -25°C for two-conductor cables and -10°C for three-conductor cables (with suitable handling procedures). Material should be properly stored above 0°C for 24 hours prior to installation. The maximum voltage rating for all intended applications is 300 volts. Consult the Canadian Electrical Code for further information related to applications.

    Specifications:

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • CSA C22.2 No. 48 non-metallic sheathed cable
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • FT1 Flame Test (1,706 BTU/Hr nominal - Vertical Wire Flame Test)
  • Sample Print Legend:

    SOUTHWIRE CSA LL90458 12 AWG 2 CDRS BLACK/WHITE NMD90 NYLON ROMEX(R) BRAND SIMpull (TM) (-25C) 300 VOLTS FT1 COVERED & MADE UNDER U.S. PAT. NOS 7557301 & 7411129. [Jacket Colour is yellow]
    Table 1 – Physical and Electrical Data
    Stock NumberCond. SizeCond. NumberCond. StrandsDiameter Over Cond.Insul. ThicknessGroundJacket ThicknessApprox. ODCopper WeightApprox. WeightDC Resistance @ 25°CAC Resistance @ 75°CInductive RectanceMin Bending RadiusAllowable Ampacity 75°CAllowable Ampacity 90°CJacket Color
    AWGNo.strandsinchmilNo. x AWGmilinchlb/1000ftlb/1000ftΩ/1000ftΩ/1000ftΩ/1000ftinchAmpAmp
    14 AWG
    471748◊142SOLID0.064351 x 14300.196x0.39637692.6313.2650.0581.52025WE
    672477◊142SOLID0.064351 x 14300.196x0.39637692.6313.2650.0581.52025RD
    551373◊142SOLID0.064351 x 14300.196x0.39637692.6313.2650.0581.52025BE
    471797◊143SOLID0.064351 x 14300.38950912.6313.2650.0581.62025WE
    12 AWG
    471755◊122SOLID0.08351 x 14300.213x0.43052881.6622.0630.0541.62530YW
    472308◊122SOLID0.08351 x 14300.213x0.43052881.6622.0630.0541.62530RD
    471805◊123SOLID0.08351 x 14300.429721181.6622.0630.0541.72530YW
    10 AWG
    472316◊102SOLID0.101351 x 12300.234x0.488831241.041.2910.051.83540RD
    471763◊102SOLID0.101351 x 12300.234x0.488831241.041.2910.051.83540OE
    471813◊103SOLID0.101351 x 12300.481151681.041.2910.051.93540OE
    8 AWG
    551038◊8270.141401 x 10450.316x0.6941332110.6530.810.0522.35055RD
    471821◊8370.141401 x 10450.6361862840.6530.810.0522.55055WE
    6 AWG
    557881◊6270.177501 x 8450.374x0.8002133400.4110.510.0512.76575RD
    471839◊6370.177501 x 8450.7762974330.4110.510.0513.16575WE
    4 AWG
    557727◊4270.225501 x 8600.8393124630.2580.320.0483.48595RD
    557882◊3270.252501 x 6800.9384106030.2050.2540.0473.8100115RD
    676254◊3370.252501 x 6801.0295748120.2050.2540.0475.1100115WE
    2 AWG
    557880◊2370.282501 x 6800.9927038620.1620.2010.0454115130RD
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item