SPEC 22061

RW90 Copper Circuit Sizes (14, 12 & 10 AWG)

Copper Conductor, 600V, 90°C MAX, -40°C MIN. All Sizes and Colors are Sunlight Resistant.

...

Construction:

  1. Conductor:Class B compressed stranded bare copper per ASTM B3 and ASTM B8
  2. Insulation:Cross Linked Polyethylene (XLPE)

Applications and Features:

Single copper conductor with low temperature, moisture resisting XLPE (cross linked polyethylene) insulation. All sizes are Sunlight Resistant in all colors and packaging. This product meets the current RoHS requirements. No lead is added or used in manufacturing.

Specifications:

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • CSA C22.2 No. 38 Thermoset-insulated wires and cables
  • CSA SUN RES - for Sunlight Resistant rating
  • Sample Print Legend:

    SOUTHWIRE& LL90458 (CSA) 12 AWG CU RW90 XLPE 600 VOLTS (-40{D}C) SR
    Table 1 – Weights and Measurements
    Stock NumberCond. SizeCond. NumberStrandInsul. ThicknessInsulation ColorApprox. ODApprox. WeightMin Bending RadiusMax Pull TensionDC Resistance @ 25°CAC Resistance @ 75°CInductive Reactance @ 60HzAllowable Ampacity In Raceway 90°C
    AWG/KcmilNo.milinchlb/1000ftinchlbΩ/1000ftΩ/1000ftΩ/1000ftAmp
    557920101730BN0.177390.700831.0401.2530.05040
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item
    †Ampacities derived from the 2015 Canadian Electrical Code - Table 1 - For single conductor in free air and based on an ambient temperature of 30°C. - Table 2 - for Cable in Conduit. Not more than 3 aluminum conductors in a conduit and based on an ambient temperature of 30°C.
    TBA stock codes are estimations only and actual product may vary. Please wait until a stock code is assigned to purchase connectors and/or fittings.
    Table 2 – Weights and Measurements (Metric)
    Stock NumberCond. SizeCond. NumberStrandInsul. ThicknessInsulation ColorApprox. ODApprox. WeightMin Bending RadiusMax Pull TensionDC Resistance @ 25°CAC Resistance @ 75°CInductive Reactance @ 60HzAllowable Ampacity In Raceway 90°C
    AWG/KcmilNo.mmmmkg/kmmmnewtonΩ/kmΩ/kmΩ/kmAmp
    55792010170.76BN4.505817.783693.414.110.164040
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item
    †Ampacities derived from the 2015 Canadian Electrical Code - Table 1 - For single conductor in free air and based on an ambient temperature of 30°C. - Table 2 - for Cable in Conduit. Not more than 3 aluminum conductors in a conduit and based on an ambient temperature of 30°C.
    TBA stock codes are estimations only and actual product may vary. Please wait until a stock code is assigned to purchase connectors and/or fittings.

    Table 3 - Stock Code Colors

    Size (Strand)ColorStock Number
    14 (Solid)BK956110
    14 (Solid)RD956177
    14 (Solid)WE956144
    14 (Solid)BN956250
    14 (Solid)YW956276
    14 (Solid)GN956201
    14 (Solid)BE956235
    14 (Solid)OE557917
    14 (7)GN955617
    14 (7)RD955245
    14 (7)BE955666
    14 (7)YW955708
    14 (7)BK951731
    14 (7)OE557924
    14 (7)BN955682
    12 (Solid)OE557861
    12 (Solid)BK956102
    12 (Solid)RD956169
    12 (Solid)BE956227
    12 (Solid)BN956243
    12 (Solid)YW956268
    12 (Solid)WE956136
    12 (Solid)GN956193
    12 (7)BK951749
    12 (7)GN955609
    12 (7)BE955658
    12 (7)BN955674
    12 (7)RD955237
    12 (7)OE557923
    12 (7)YW955690
    10 (Solid)RD956151
    10 (Solid)OE557930
    10 (Solid)BK956094
    10 (Solid)BN557929
    10 (Solid)WE956128
    10 (Solid)GN956185
    10 (Solid)BE956219
    10 (7)BK951756
    10 (7)BE955641
    10 (7)OE557921
    10 (7)GN955591
    10 (7)BN557920
    10 (7)YW557922
    10 (7)RD955229

    Revision: 1.000.011