SPEC 13115

Broadband Coax - RG6, RG59 and 18/2 Siamese

...

Construction:

Non-Plenum Rated
  1. Conductor:Bare copper or copper clad steel
  2. Insulation:Polyethylene
  3. Shield:Copper braid shielded
  4. Signal:2/C #18 Black, Red
  5. Jacket:Polyvinyl Chloride PVC.

Plenum Rated
  1. Conductor:Bare copper or copper clad steel
  2. Insulation:Foamed Fluoropolymer
  3. Shield:Copper braid shielded
  4. Signal:2/C #18 Black, Red
  5. Jacket:Polyvinyl Chloride PVC.

Applications and Features:

CATV Applications for distributing television signals, using “F” connectors, ALUMINUM BRAID CCTV Applications for surveillance; Connecting security cameras, DVR or monitor using “BNC” connectors, COPPER BRAID

  • Flame Test Non-Plenum: UL 1685/CSA FT1
  • Flame Test Plenum: NFPA 262/CSA FT6
  • Specifications:

  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
  • Sample Print Legend:

    {SQFTG} SOUTHWIRE® SIGNAL® 993267 1C18 AWG RG 6/U 2C 18 AWG E57497 (UL) CM/CL2 SUN RES

    {SQFTG} SOUTHWIRE® SIGNAL® 993265 1C18 AWG RG 6/U 2C 18 AWG TYPE CL2P/CMP C(ETL)US -- TYPE CMP FT6

    {SQFTG} SOUTHWIRE® SIGNAL® 993254 1C20 AWG RG 59/U 2C18 AWG DIRECT BURIAL SUN RES
    Table 1 – Physical and Electrical Data
    Stock NumberCable TypeRatingCond. SizeCond. NumberCond. TypeCond. StrandsInsul. ThicknessApprox. ODApprox. WeightShield TypeApplication
    AWGNo.strandsmilinchlb/1000ft
    RG59
    993256RG59CMP/CL2P201BCSolid550.198 x 0.36847Copper BraidCATV
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item

    Revision: 1.000.037

    Updated On: Dec. 13, 2024, 5:37 p.m. UTC