SPEC 13086

Soundsational® Speaker Cable, General Purpose

300V, 75°C, General Purpose Southwire Signal Speaker Cable, In-Wall Rated, Stranded Bare Copper CL3

...

Construction:

  1. Conductor:Stranded Class M bare copper
  2. Insulation:High Density Polyethylene HDPE
  3. Jacket:Polyvinyl Chloride PVC

Applications and Features:

Southwire Soundsational® general purpose speaker cable is suitable for installation as follows:
• Installed in a metal raceway that complies with 300.22(B).
• Supported by solid bottom metal cable trays with solid metal covers.
• Within buildings in other than air-handling spaces and risers.
• Exposed to sunlight.

Specifications:

  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • UL 13 Power-Limited Circuit Cables
  • UL 444 Communications Cables (22 AWG - 16 AWG)
  • CSA C22.2 No. 2556 / UL 2556 Cable Test Methods
  • RoHS Compliant Lead-Free, Silicone-Free, Halogen Free
  • Sunlight Resistance
  • Sample Print Legend:

    {SQFTG} SOUTHWIRE{R} SIGNAL{R} XXXX SOUNDSATIONAL XX AWG X/C C(ETL)US TYPE CM/CL3 75{D}C AUDIO CABLE SUN RES -- CMH FT1
    Table 1 – Physical and Electrical Data
    Stock NumberCond. SizeCond. NumberCond. StrandsDiameter Over Cond.Jacket ThicknessApprox. ODCopper WeightApprox. WeightDC Resistance @ 25°CAC Resistance @ 75°CInductive Rectance
    AWGNo.strandsinchmilinchlb/1000ftlb/1000ftΩ/1000ftΩ/1000ftΩ/1000ft
    14 AWG
    947441441050.073200.25952652.8143.3910.058
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item

    Revision: 1.000.011

    Updated On: July 28, 2025, 2:46 a.m. UTC