SPEC 60375

Armorlite® Type MC XHHW-2 Aluminum Conductor Feeder Cable. Rated 600 or 1000 Volts. Silicone Free

Aluminum XHHW-2 Insulated Singles with 8000 series Triple E™ Aluminum Alloy. Bare AlumaFlex™ Aluminum Alloy Grounding Conductor. UL Listed. 600 or 1000 Volts. Rated VW-1. Lightweight Aluminum Interlocked Armor.

...

Construction:

  1. Conductor:Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B801
  2. Insulation:All phases are insulated with Cross Linked Polyethylene XLPE Type XHHW-2
  3. Ground:Bare aluminum ground
  4. Filler:Fillers as needed
  5. Binder:Mylar tape
  6. Armor:Aluminum Interlocked Armor

Applications and Features:

Southwire Armorlite® Type MC Feeder cable is suitable for use as follows:
- Feeder and service power distribution in commercial, industrial, institutional, and multi-residential buildings.
- Fished or embedded in plaster.
- Concealed or exposed installations.
- Environmental air-handling spaces per NEC 300.22 (C).
- Places of Assembly per NEC 518.4 and theaters per NEC 520.5.
- Installation in cable tray and approved raceways.
- Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(E)
- Class I Div. 2, Class II Div 2, & Class III Div. 1 Hazardous Locations.
- Binder tape with print legend wrapped around assembly.
- Type XHHW-2 rated 90ºC Wet and Dry
- Per NEC (330.10), unjacketed MC cable can be used in dry location

Southwire Armorlite® Type MC Feeder Cable - meets or exceeds the following requirements:
- UL Online Product Guide Info - Metal-Clad Cable (PJAZ) ( www.ul.com )
- Federal Specification A-A59544 (formerly J-C-30B)
- NFPA 70 (National Electrical Code), Article 330
- Listed for use in UL 1, 2 and 3 Hour Through Penetration Firestop Systems

Specifications:

  • ASTM B800 8000 Series Aluminum Alloy Wire
  • ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy
  • UL 44 Thermoset-Insulated Wires and Cables
  • UL 1569 Metal-Clad Cables
  • UL 1479 Standard for Safety Fire Tests of Penetration Firestops
  • UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
  • RoHS-2 (European Directive 2011/65/EU)
  • Buy American: Compliant with Buy American Requirements, found in 49 U.S.C. § 5323(j); specify “Made in the USA Only!” when ordering to ensure your project receives American made products.
  • Sample Print Legend:

    E96627 {UL} TYPE MC AWG XX XHHW-2 CDRS FOR USE IN CABLE TRAYS 600 VOLTS
    Table 1 – Weights and Measurements
    Stock NumberCond. SizeConductor NumberColorDiameter Over ConductorConductor StrandingInsulation ThicknessGround SizeDiameter Over ArmorOverall Weight
    AWG/KcmilinchmilsNo. x AWGinchlbs/1000ft
    890092◊63BK,BK/RD,BK/WE0.1697451x60.844242
    600742◊43BK,BK/RD,BK/WE0.2137451x61.01333
    557199◊23BK,BK/RD,BK/WE0.2686451x41.056430
    558064◊13BK,BK/RD,BK/WE0.2998551x41.163523
    641793◊1/03BK,BK/RD,BK/WE0.33610551x41.261610
    641798◊3/03BK,BK/RD,BK/WE0.42315551x41.449838
    641800◊4/03BK,BK/RD,BK/WE0.47519551x21.5821077
    641802◊2503BK,BK/RD,BK/WE0.5222651x21.7181248
    641805◊3003BK,BK/RD,BK/WE0.5721651x21.8261428
    641807◊3503BK,BK/RD,BK/WE0.61635651x21.9251603
    643393◊4003BK,BK/RD,BK/WE0.65935651x12.0181794
    643396◊5003BK,BK/RD,BK/WE0.73634651x12.1842136
    643398◊7503BK,BK/RD,BK/WE0.90858801x1/02.6253083
    611203◊64BK,BK/RD,BK/BE,BK/WE0.1697451x60.928294
    608364◊44BK,BK/RD,BK/BE,BK/WE0.2137451x61.036382
    557249◊24BK,BK/RD,BK/BE,BK/WE0.2686451x41.169545
    559963◊14BK,BK/RD,BK/BE,BK/WE0.2998551x41.296667
    641724◊2/04BK,BK/RD,BK/BE,BK/WE0.37612551x41.477916
    641730◊3/04BK,BK/RD,BK/BE,BK/WE0.42315551x41.6081150
    641736◊4/04BK,BK/RD,BK/BE,BK/WE0.47519551x21.7421391
    641743◊2504BK,BK/RD,BK/BE,BK/WE0.5222651x11.8971631
    641750◊3004BK,BK/RD,BK/BE,BK/WE0.5721651x12.0071871
    641757◊3504BK,BK/RD,BK/BE,BK/WE0.61635651x1/02.1272124
    641764◊4004BK,BK/RD,BK/BE,BK/WE0.65935651x1/02.2222351
    641770◊5004BK,BK/RD,BK/BE,BK/WE0.73634651x2/02.4112828
    641776◊7504BK,BK/RD,BK/BE,BK/WE0.90858801x3/02.8994110
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item
    * Strand count meets minimum number per ASTM
    GG - Green Ground
    TBA stock codes are estimations only and actual product may vary. Please wait until a stock code is assigned to purchase connectors and/or fittings.
    Table 2 – Electrical and Engineering Data
    Cond. SizeConductor NumberMin. Bend RadiusMax Pull TensionDC Resistance at 25°CAC Resistance at 75°CInductive Reactance @ 60HzAllowable Ampacity Raceway 75°CAllowable Ampacity Raceway 90°C
    AWG/KcmilInchesLbsΩ/1000ftΩ/1000ftΩ/1000ftAmpAmp
    635.94720.6740.840.0515055
    437.17510.4240.5280.0486575
    237.411940.2660.3310.04590100
    138.115060.2110.2630.046100115
    1/038.819000.1670.2080.044120135
    3/0310.130200.1050.1310.042155175
    4/0311.138080.0840.1050.041180205
    25031245000.070.0870.041205230
    300312.854000.0590.0740.041230260
    350313.563000.0510.0640.04250280
    400314.172000.0440.0550.04270305
    500315.390000.0360.0450.039310350
    750318.4135000.0230.030.038385435
    646.56290.6740.840.0514044
    447.310010.4240.5280.0485260
    248.215920.2660.3310.0457280
    149.120080.2110.2630.0468092
    2/0410.331940.1330.1660.043108120
    3/0411.340270.1050.1310.042124140
    4/0412.250780.0840.1050.041144164
    250413.360000.070.0870.041164184
    30041472000.0590.0740.041184208
    350414.984000.0510.0640.04200224
    400415.696000.0440.0550.04216244
    500416.9120000.0360.0450.039248280
    750420.3180000.0230.030.038308348
    * Ampacities based upon 2023 NEC Table 310.16. See NEC sections 310.15 and 110.14(C) for additional requirements.
    * Ampacities have been adjusted for more than Three Current-Carrying Conductors.

    Revision: 1.000.005

    Updated On: Dec. 31, 2024, 11:08 p.m. UTC