SPEC 48403
CU 600V NLEPR/PE Duplex Track Wire
600 Volt, 90°C, AREMA PART 10.3.16

Construction:
- Conductor:Solid bare copper per ASTM B3
- Insulation:High Performance No Lead Ethylene Propylene Rubber (NL-EPR)
- Jacket:Polyethylene (PE)
Applications and Features:
Southwire 600V No Lead EPR/PE Duplex Track Wire is suited for use in track circuits, signal operations, and car retarder and switch machine applications where flexibility, ease of termination, and stable service life are required. May be installed in wet or dry locations, conduit trays or troughs, or directly buried. These cables are capable of operating continuously at a conductor temperature not in excess of 90°C for normal operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions.
• Mechanically rugged
• High Performance No Lead EPR
• Excellent moisture resistance
• Resistant to heat, aging, and environmental hazards
• Cleanly strips from conductor
• Superior deformation resistance
• RoHS/Proposition 65 Compliant
• Mechanically rugged
• High Performance No Lead EPR
• Excellent moisture resistance
• Resistant to heat, aging, and environmental hazards
• Cleanly strips from conductor
• Superior deformation resistance
• RoHS/Proposition 65 Compliant
Specifications:
Table 1 – Weights and Measurements
All dimensions are nominal and subject to normal manufacturing tolerances
◊ Cable marked with this symbol is a standard stock item
TBA stock codes are estimations only and actual product may vary. Please wait until a stock code is assigned to purchase connectors and/or fittings.
Revision: 1.000.004
Updated On: May 19, 2026, 5:44 p.m. UTC

