SPEC 48317

40% High Strength Copper Clad Steel

...

Construction:

Stranded Copper-Clad Steel per ASTM A460

Applications and Features:

40% Conductivity High Strength Copper-Clad Steel Wire is designed for use as guy wires for overhead lines, messengers, or span wires. Features higher tensile strength with minimal sag compared to solid copper. Resistant to permanent stretch caused by seasonal changes in temperature and less susceptible to cracking from repeated flexing and mechanical vibration. With very little scrap value, discourages theft.

Specifications:

  • ASTM A460 Standard Specification for Copper-Clad Steel Wire Strand
  • ASTM B227 Standard for Hard-Drawn Copper-Clad Steel Wire
  • Table 1 – Weights and Measurements
    Stock NumberCond. SizeStrand CountApprox. ODCond. AreaRated Breaking StrengthApprox. WeightDC Resistance @ 20°C
    AWGNo. of Strandsinchcmillbs.lbs./1000ftΩ/1000ft
    CC-1003319#4191.022793000587382251.70.0331
    CC-1003419#5190.9106287004871917850.0418
    CC-1003519#6190.810498600403531415.80.0527
    CC-1003619#7190.722395600333731123.30.0664
    CC-1003719#8190.64331370027541890.80.0837
    CC-1003819#9190.57224870022681706.00.1057
    CC-100394/0190.52821150019289600.40.1242
    CC-1004019#10190.51019730018753560.20.1332
    CC-100417#470.61329220021640826.30.0896
    CC-100427#570.54623160017949655.00.1130
    CC-100437#670.48618370014867519.60.1424
    CC-100447#770.43314580012295412.20.1795
    CC-100452/070.41413310011229376.50.1966
    CC-100467#870.38611560010147326.90.2264
    CC-100471/070.3681056009266298.50.2479
    736102407#970.343916108356259.10.2856
    CC-100487#1070.306726906909205.60.3600
    73610340270.258517004971146.00.5054

    Revision: 1.000.002

    Updated On: Sept. 5, 2024, 2:59 p.m. UTC