SPEC 44080

Southwire® RenewaFLEX™ Power Cables for Battery Energy Storage Systems

Single Conductor Copper 2000V XLPE insulation Type RHH/RHW-2 Flexible Power Cable.

...

Construction:

  1. Conductor: 6 - 4/0 AWG: Class K, Flexible stranded bare copper. 250 - 750 kcmil: Class I, Flexible stranded bare copper
  2. Insulation: Cross Linked Polyethylene (XLPE) Type RHH/RHW-2

Applications and Features:

Southwire’s 2000 Volt power cables are suited for use in the internal wiring of Battery Energy Storage Systems (BESS), in wet and dry locations, conduits, ducts, troughs, covered trays, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation, 130°C for emergency overload, and 250°C for short circuit conditions. Gasoline and Oil Resistant. For CT USE sizes 1/0 AWG and larger. Rated 1000 lbs./FT maximum sidewall pressure.
Also available in different colors like: Black, Red, Green, Brown, Yellow, etc.

Specifications:

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors
  • UL 44 Thermoset-Insulated Wires and Cables
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
  • RoHS-3 Complies with European Directive 2015/863
  • Made in America: Compliant with both Buy American and Buy America Act (BAA) requirements per 49 U.S.C. § 5323(j) and the Federal Transit Administration Buy America requirements per 49 C.F.R. part 661
  • Sample Print Legend:

    For 8-2 AWG: {SQFTG} SOUTHWIRE E30117 {UL} XX AWG CU TYPE RHH OR RHW-2 XX MILS XLP PRI/II GRI/II 2000 VOLTS

    For 1/0-4/0 AWG: {SQFTG} SOUTHWIRE E30117 {UL} XX AWG CU TYPE RHH OR RHW-2 XX MILS XLP FOR CT USE PRI/II GRI/II 2000 VOLTS

    For 250-750 kcmil: {SQFTG} SOUTHWIRE E30117 {UL} XX kcmil CU TYPE RHH OR RHW-2 XX MILS XLP FOR CT USE PRI/II GRI/II 2000 VOLTS
    Table 1 – Weights and Measurements
    Stock NumberCond. SizeStrandDiameter Over ConductorInsul. ThicknessApprox. ODApprox. Weight
    AWG/KcmilNo.inchmilinchlb/1000ft
    TBA81680.153700.29377
    66577762730.190700.338119
    66577644130.235700.383164
    66577526650.302700.448252
    6654221/010640.385900.570426
    1389232/013300.410900.620510
    1389244/021090.550900.740788
    1389252506270.5801050.825908
    1389263508930.6701050.8901242
    13892750012210.8581051.0781709
    13895060014800.9631201.2152112
    13895175018501.0941201.3462650
    TBA100025161.1901201.4303302
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item
    Table 2 – Electrical and Engineering Data
    Cond. SizeMin Bending RadiusMax Pull TensionDC Resistance @ 25°CAC Resistance @ 90°CInductive Reactance @ 60HzAllowable Ampacity In Air 90°CAllowable Ampacity In Raceway 90°C
    AWG/KcmilinchlbΩ/1000ftΩ/1000ftΩ/1000ftAmpAmp
    82.31320.7150.9030.0528055
    62.72090.4190.5240.05110575
    43.03330.2630.3290.04814095
    23.55310.1650.2070.045190130
    1/04.58450.1050.1320.044260170
    2/04.710650.0840.1050.043300195
    4/05.816930.0530.0670.041405260
    2506.520000.0450.0560.041455290
    3507.028000.0320.0400.040570350
    5008.540000.0220.0290.039700430
    6009.648000.0190.0240.039780475
    75010.660000.0150.0250.038885535
    100011.480000.0110.0210.0371055615
    † Ampacities based upon 2023 NEC Table 310.16 for Raceway, Cable, or Earth.
    † NEC Table 310.17 for single conductors in Air.
    * Inductive impedance is based on non-ferrous conduit with one diameter spacing center-to-center.
    Table 3 – Weights and Measurements (Metric)
    Stock NumberCond. SizeStrandDiameter Over ConductorInsul. ThicknessApprox. ODApprox. Weight
    AWG/KcmilNo.mmmmmmkg/km
    TBA81683.891.787.44115
    66577762734.831.788.59177
    66577644135.971.789.73244
    66577526657.671.7811.38375
    6654221/010649.782.2914.48634
    1389232/0133010.412.2915.75759
    1389244/0210913.972.2918.801173
    13892525062714.732.6720.961351
    13892635089317.022.6722.611848
    138927500122121.792.6727.382543
    138950600148024.463.0530.863143
    138951750185027.793.0534.193944
    TBA1000251630.233.0536.324914
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item
    Table 4 – Electrical and Engineering Data (Metric)
    Cond. SizeMin Bending RadiusMax Pull TensionDC Resistance @ 25°CAC Resistance @ 90°CInductive Reactance @ 60HzAllowable Ampacity In Air 90°CAllowable Ampacity In Raceway 90°C
    AWG/KcmilmmnewtonΩ/kmΩ/kmΩ/kmAmpAmp
    858.425872.34582.960.17068055
    668.589301.37471.720.167310575
    476.2014820.86291.080.157514095
    288.9023630.54130.680.1476190130
    1/0114.3037600.34450.430.1444260170
    2/0119.3847390.27560.340.1411300195
    4/0147.3275340.17390.220.1345405260
    250165.1089000.14760.180.1345455290
    350177.80124600.10500.130.1312570350
    500215.90178000.07220.100.1280700430
    600243.84213600.06230.080.1280780475
    750269.24267000.04920.080.1247885535
    1000289.56356000.03610.070.12141055615
    † Ampacities based upon 2023 NEC Table 310.16 for Raceway, Cable, or Earth.
    † NEC Table 310.17 for single conductors in Air.
    * Inductive impedance is based on non-ferrous conduit with one diameter spacing center-to-center.

    Revision: 1.000.029

    Updated On: Oct. 24, 2024, 1:25 p.m. UTC