SPEC 85047

Multi-Conductor CU 1000 V FR-XLPE Shielded Thermoset LSZH Jacket Control Cable Color Method 1 Table 1

Control Cable 1000 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded Thermoset SOLONON® Low Smoke Zero Halogen (LSZH-TS) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free

...

Construction:

  1. Conductor: 7 strands class B compressed bare copper per ASTM B3 and ASTM B8
  2. Insulation: Flame Retardant Cross Linked Polyethylene (FR-XLPE)
  3. Filler: Polypropylene filler
  4. Binder: Polypropylene tape
  5. Shielding: 5 mil copper Helically-Applied Tape shield
  6. Rip Cord: Rip cord for ease of jacket removal
  7. Overall Jacket: Thermoset SOLONON® Low Smoke Zero Halogen (LSZH-TS) Jacket

Applications and Features:

Southwire’s 1000 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.

Specifications:

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 1
  • ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • Sample Print Legend:

    SOUTHWIRE XX AWG X/C FR-XLPE CDRS SHIELDED 90C LSZH JACKET SUNLIGHT RESISTANT DIRECT BURIAL 1000V {MMM/DD/YYYY} {SEQUENTIAL FOOTAGE MARKS} SEQ FEET
    Table 1 – Physical and Electrical Data
    Stock NumberCond. SizeCond. NumberCond. StrandsDiameter Over Cond.Insul. ThicknessJacket ThicknessApprox. ODCopper WeightApprox. WeightDC Resistance @ 25°CAC Resistance @ 75°CInductive RectanceMin Bending RadiusAllowable Ampacity 75°CAllowable Ampacity 90°C
    AWGNo.strandsinchmilmilinchlb/1000ftlb/1000ftΩ/1000ftΩ/1000ftΩ/1000ftinchAmpAmp
    14 AWG
    TBA14570.07045600.6141312382.6313.1700.0587.41620
    62189414770.07045600.6401282752.6313.1700.0587.71417
    621892141270.07045600.8722064662.6313.1700.05810.51012
    12 AWG
    66094112470.08830450.4831091811.6622.0020.0545.82024
    626177!12470.08845600.5881152321.6622.0020.0547.12024
    626172!12770.08845600.6931833481.6622.0020.0548.31721
    660930121270.08830600.7792914721.6622.0020.0549.31215
    626166!121270.08845800.9463025921.6622.0020.05411.412.515
    10 AWG
    62189910470.11330600.5781622751.0401.2530.0506.92832
    62188510370.11345600.5921322521.0401.2530.0504.13540
    TBA10470.11345600.6391712851.021.3140.0317.72832
    626152!10470.11345600.6441713071.0401.2530.0504.52832
    62188710770.11345600.7652724641.0401.2530.0505.42428
    621883101070.11345801.0123846861.0401.2530.05012.11720
    623760101270.11345801.0444517881.0401.2530.05012.51720
    8 AWG
    TBA8370.14245600.6461973240.640.8240.0327.85055
    TBA8470.14245600.7072533830.640.8240.0328.54044
    6 AWG
    6244106470.17755800.9013806570.4110.4950.0516.35260
    TBA6370.17845600.722954430.4110.5350.0318.66575
    4 AWG
    TBA4370.22545600.8644496610.2580.3360.02910.48595
    2 AWG
    6244092270.28255800.9784727070.1620.1950.0456.8115130
    TBA2370.28245800.9876899440.1620.2110.02711.8115130
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item
    !Drain wire
    † Rated 600 Volts
    * Ampacities based upon 2023 NEC Table 310.16 and do not take into account the overcurrent protection limitations in NEC 240.4(D) of 15 Amps for 14 AWG CU, 20 Amps for 12 AWG CU, and 30 Amps for 10 AWG CU (independent of the conductor temperature rating and stranding if size is present in table). Also, see NEC sections 310.15 and 110.14(C) for additional requirements. Ampacities have been adjusted for stock numbers containing more than Three Current-Carrying Conductors.

    Revision: 1.000.068

    Updated On: July 3, 2024, 10:14 p.m. UTC