SPEC 85025

Multi-Conductor CU 600 V FR-XLPE LCT Shielded Thermoplastic CPE-TP Jacket Control Cable Color Method 1 Table 2

Control Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded Thermoplastic Chlorinated Polyethylene (CPE-TP) Jacket, Control Cable Conductor Identification Method 1 Table 2. Silicone Free

...

Construction:

  1. Conductor:7 strands class B compressed bare copper per ASTM B3 and ASTM B8
  2. Insulation:Flame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes
  3. Filler:Polypropylene filler on cables with 5 or less conductors
  4. Binder:Polyester flat thread binder tape applied for cables with more than 5 conductors
  5. Shield:5 mils copper Longitudinally-Applied Corrugated Tape (LCT) shield
  6. Rip Cord:Rip cord for ease of jacket removal
  7. Overall Jacket:Thermoplastic Chlorinated Polyethylene (CPE-TP)

Applications and Features:

Southwire’s 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.

Specifications:

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • UL 44 Thermoset-Insulated Wires and Cables
  • UL 1277 Electrical Power and Control Tray Cables
  • UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
  • ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2
  • ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu/hr) and ICEA T-29-520 - (210,000 Btu/hr)
  • VW-1 (Vertical-Wire) Flame Test
  • Sample Print Legend:

    UL Listed
    SOUTHWIRE {UL} E75755 XX AWG CU X/C FR-XLPE E2 CDRS SHIELDED TYPE TC CPE JACKET 600V YEAR {SEQUENTIAL FOOTAGE MARKS} SEQ FEET

    Non UL Listed
    SOUTHWIRE XX AWG CU X/C FR-XLPE E2 CDRS SHIELDED CPE JACKET 600V SUN RES DIR BUR YEAR {SEQUENTIAL FOOTAGE MARKS} SEQ FEET

    Table 1 – Physical and Electrical Data
    Stock NumberCond. SizeCond. NumberCond. StrandsDiameter Over Cond.Insul. ThicknessJacket ThicknessApprox. ODCopper WeightApprox. WeightDC Resistance @ 25°CAC Resistance @ 75°CMin Bending RadiusAllowable Ampacity 90°CJacket Color
    AWGNo.strandsinchmilmilinchlb/1000ftlb/1000ftΩ/1000ftΩ/1000ftinchAmp
    18 AWG
    606981182070.03625600.733842926.6698.0352.98Black
    14 AWG
    TBA14270.07030450.452481072.6313.1705.425Black
    TBA14370.07030450.472621282.6313.1705.725Black
    TBA14470.07030450.506781382.6313.1706.120Black
    626270^14470.07030450.514841742.6313.1706.220Black
    TBA14570.07030600.573931772.6313.1706.920Black
    TBA14670.07030600.6121102042.6313.1707.320Black
    TBA14770.07030600.6121232222.6313.1707.317Black
    TBA14870.07030600.6521392482.6313.1707.817Black
    TBA14970.07030600.6911562742.6313.1708.317Black
    TBA141070.07030600.7421723012.6313.1708.912Black
    TBA141270.07030600.7622003412.6313.1709.112Black
    TBA141570.07030800.8742444422.6313.17010.512Black
    TBA141970.07030800.9122995232.6313.17010.912Black
    TBA142070.07030800.9523155502.6313.17011.412Black
    TBA142570.07030801.0423866602.6313.17012.511Black
    TBA143070.07030801.0954557622.6313.17013.111Black
    TBA143770.07030801.1725529052.6313.17014.110Black
    12 AWG
    66186412270.08830450.488741431.6622.0025.930Black
    TBA12370.08830450.511891631.6622.0026.130Black
    622950^12470.08830600.5751202251.6622.0026.924Black
    TBA12570.08830600.6211362301.6622.0027.524Black
    622948^12770.08830600.6611873241.6622.0027.921Black
    TBA12670.08830600.6661602651.6622.0028.024Black
    TBA12870.08830600.7112043271.6622.0028.521Black
    TBA12970.08830600.7562293631.6622.0029.121Black
    TBA121070.08830600.8142544001.6622.0029.815Black
    622953^121270.08830800.8722995291.6622.00210.515Black
    TBA121570.08830800.9593655901.6622.00211.515Black
    TBA121970.08830801.0024507051.6622.00212.015Black
    TBA122070.08830801.0474747421.6622.00212.615Black
    TBA122570.08830801.1505858981.6622.00213.813Black
    TBA123070.08830801.21069210431.6622.00214.513Black
    TBA123770.08830801.29884112471.6622.00215.612Black
    10 AWG
    622946^10270.11330600.5661031981.0401.2536.840Black
    TBA10370.11330600.5951292331.0401.2537.140Black
    622943^10470.11330600.6321732931.0401.2537.632Black
    606859^10470.11330600.6521623001.0401.2537.832Black
    66221610570.11330600.6852063441.0401.2538.232Black
    TBA10670.11330600.7412393611.0401.2538.932Black
    62220910770.11330600.7512764461.0401.2539.028Black
    TBA10870.11330600.7943074501.0401.2539.528Black
    TBA10970.11330800.8863455351.0401.25310.628Black
    TBA101070.11330800.9543835911.0401.25311.420Black
    662217101270.11330800.9714557221.0401.25311.720Black
    TBA101570.11330801.0765558171.0401.25312.920Black
    TBA101970.11330801.1276899871.0401.25313.520Black
    TBA102070.11330801.18072510391.0401.25314.220Black
    TBA102570.11330801.30089812661.0401.25315.618Black
    TBA103070.11330801.370106614801.0401.25316.418Black
    TBA103770.11330801.473130017791.0401.25317.716Black
    8 AWG
    TBA8270.14145600.6841422740.6530.7868.255Black
    62298481270.14145801.22570111110.6530.78614.727Black
    6 AWG
    622994^6270.17745600.7562133650.4110.4959.175Black
    6618636470.17745800.9113776270.4110.49510.960Black
    4 AWG
    622996^4270.22545800.8943155240.2580.31010.795Black
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item
    ^ UL listed part number
    * Ampacities based upon 2023 NEC Table 310.16 and do not take into account the overcurrent protection limitations in NEC 240.4(D) of 15 Amps for 14 AWG CU, 20 Amps for 12 AWG CU, and 30 Amps for 10 AWG CU (independent of the conductor temperature rating and stranding if size is present in table). Also, see NEC sections 310.15 and 110.14(C) for additional requirements. Ampacities have been adjusted for stock numbers containing more than Three Current-Carrying Conductors.