SPEC 70070

600V SEOPRENE® SEOOW Cord Control 105°C. Silicone-Free

600 Volt Cord. -50°C to 105°C Premium Oil Resistance, Sunlight, Water Resistance and Flame Retardant

...

Construction:

  1. Conductor:Class K stranded bare copper per ASTM B-174
  2. Insulation:Heat, moisture and oil resistant TPE
  3. Filler:Non-wicking polypropylene fillers, with a tissue-paper separator wrapped around the assembly
  4. Jacket:TPE

Applications and Features:

Southwire Type SEOOW Flexible Cords UL/ CSA listed are permitted for use as specified by Article 400 and related articles of the 2020 National Electrical Code. The cable is rated -50°C to 105°C, water, oil, and weather resistant. Southwire Type SEOOW Flexible Cords are designed for extra hard usage on industrial equipment, heavy tools, battery chargers, portable lights, welding leads, marine dockside power, power extensions and mining applications.

Specifications:

  • UL 62 Flexible Cords and Cables
  • CSA C22.2 No. 49 Flexible Cords and Cables
  • Passes CSA FT2 Flame Test
  • RoHS-3 Complies with European Directive 2015/863
  • NEC Article 400 Flexible Cords, Cables and Fixture Wire
  • NEC Article 501.140 Class I Division 2
  • Sample Print Legend:

    SOUTHWIRE® SEOPRENE® CORD X/C XX AWG (X.XXmm2) SEOOW E46194 (UL) 600V -50C TO 105C -- CSA LL90458 SEOOW 600V -50C TO 105C FT2 WATER RESISTANT

    Packaging:

    Standard lengths: 250', 500' and 1,000' reels. Other lengths available upon request.
    Table 1 – Weights and Measurements
    Stock NumberCond. SizeCond. NumberCond. StrandsInsul. ThicknessJacket ThicknessApprox. ODApprox. WeightAmpacityDC ResistanceInsul. ColorJacket Color
    AWG/KcmilNo.No.milmilinchlb/1000ftAmpΩ/1000ft
    5505601821630650.35256106.659BK,WEBK
    5505611831630650.3656476.659BK,WE,GNBK
    5514691841630600.3877566.659WE,BK,GN,RDBK
    5696451851630900.47211066.659BK,WE,RD,GN,OEBK
    5987581861630800.48411866.659BK,WE,RD,GN,OE,BEBK
    5987281871630800.48812556.659BK,WE,RD,GN,OE,BE,WE/BKBK
    5987291881630800.51714156.659BK,WE,RD,GN,OE,BE,WE/BK,RD/BKBK
    59873018101630800.59217546.659SEE TABLEBK
    59873118121630800.61319446.659SEE TABLEBK
    59873218141630800.6421446.659SEE TABLEBK
    59548718161630950.69726146.659SEE TABLEBK
    598733182441301000.8135136.659SEE TABLEBK
    5506341622630600.36863134.181BK,WEBK
    5504021632630650.39781104.181BK,WE,GNBK
    5504641642630650.4229584.181BK,WE,GN,RDBK
    5987641652630800.49213084.181BK,WE,RD,GN,OEWE
    5505551652630850.50213484.181BK,WE,RD,GN,OEBK
    5953751672630800.52515874.181BK,WE,RD,GN,OE,BE,WE/BKBK
    5627911662630850.53315184.181BK,WE,RD,GN,OE,BEBK
    5898881682630800.5617974.181BK,WE,RD,GN,OE,BE,WE/BK,RD/BKBK
    5987341692630850.60820274.181BK,WE,RD,GN,OE,BE,WE/BK,RD/BK,GN/BKBK
    59873516102630800.63821254.181SEE TABLEBK
    59488916122630950.69126054.181SEE TABLEBK
    59873616142630950.72529254.181SEE TABLEBK
    59873716162630950.75731754.181SEE TABLEBK
    59566716246530950.86444944.181SEE TABLEBK
    5505621424145850.507118182.621BK,WEBK
    5503981434145850.526142152.621BK,WE,GNBK
    5503991444145900.592182122.621BK,WE,RD,GNBK
    5506261454145950.642216122.621BK,WE,RD,GN,OEBK
    5987391464145950.69248122.621BK,WE,RD,GN,OE,BEBK
    5987401474145950.69267102.621BK,WE,RD,GN,OE,BE,WE/BKBK
    5987411484145950.743304102.621BK,WE,RD,GN,OE,BE,WE/BK,RD/BKBK
    58992114104145950.83536382.621SEE TABLEBK
    55043212265451000.577159251.652BK,WEBK
    55039512365451000.603193201.652BK,WE,GNBK
    55039712465451050.661242161.652BK,WE,RD,GNBK
    55049712565451150.739299161.652BK,WE,RD,GN,OEBK
    5987451266545950.755320161.652BK,WE,RD,GN,OE,BEBK
    5987461286545950.804377141.652BK,WE,RD,GN,OE,BE,WE/BK,RD/BKBK
    550431102104451100.627204301.04BK,WEBK
    550393103104451100.662252251.04BK,WE,GNBK
    550394104104451050.712310201.04BK,WE,RD,GNBK
    550875105104451100.772364201.04BK,WE,RD,GN,OEBK
    598752107104451150.845469181.04BK,WE,RD,GN,OE,BE,WE/BKBK
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item
    * Ampacities are based on TABLE 400.5(A)(1) of the 2023 National Electrical Code and CEC Table 12.
    Table 2 – Weights and Measurements (Metric)
    Stock NumberCond. SizeCond. NumberCond. StrandsInsul. ThicknessJacket ThicknessApprox. ODApprox. WeightAmpacity *DC ResistanceInsul. ColorJacket Color
    AWG/KcmilNo.No.mmmmmmkg/kmAmpΩ/km
    550560182160.761.658.94831021.85BK,WEBK
    550561183160.761.659.2795721.85BK,WE,GNBK
    551469184160.761.529.83112621.85WE,BK,GN,RDBK
    569645185160.762.2911.99164621.85BK,WE,RD,GN,OEBK
    598758186160.762.0312.29176621.85BK,WE,RD,GN,OE,BEBK
    598728187160.762.0312.40186521.85BK,WE,RD,GN,OE,BE,WE/BKBK
    598729188160.762.0313.13210521.85BK,WE,RD,GN,OE,BE,WE/BK,RD/BKBK
    5987301810160.762.0315.04260421.85SEE TABLEBK
    5987311812160.762.0315.57289421.85SEE TABLEBK
    5987321814160.762.0316.26318421.85SEE TABLEBK
    5954871816160.762.4117.70388421.85SEE TABLEBK
    5987331824410.762.5420.57522321.85SEE TABLEBK
    550634162260.761.529.35941313.72BK,WEBK
    550402163260.761.6510.081211013.72BK,WE,GNBK
    550464164260.761.6510.72141813.72BK,WE,GN,RDBK
    598764165260.762.0312.50193813.72BK,WE,RD,GN,OEWE
    550555165260.762.1612.75199813.72BK,WE,RD,GN,OEBK
    595375167260.762.0313.33235713.72BK,WE,RD,GN,OE,BE,WE/BKBK
    562791166260.762.1613.54225813.72BK,WE,RD,GN,OE,BEBK
    589888168260.762.0314.22266713.72BK,WE,RD,GN,OE,BE,WE/BK,RD/BKBK
    598734169260.762.1615.44301713.72BK,WE,RD,GN,OE,BE,WE/BK,RD/BK,GN/BKBK
    5987351610260.762.0316.21315513.72SEE TABLEBK
    5948891612260.762.4117.55387513.72SEE TABLEBK
    5987361614260.762.4118.42435513.72SEE TABLEBK
    5987371616260.762.4119.23472513.72SEE TABLEBK
    5956671624650.762.4121.95668413.72SEE TABLEBK
    550562142411.142.1612.88176188.60BK,WEBK
    550398143411.142.1613.36211158.60BK,WE,GNBK
    550399144411.142.2915.04271128.60BK,WE,RD,GNBK
    550626145411.142.4116.31321128.60BK,WE,RD,GN,OEBK
    598739146411.142.4117.53369128.60BK,WE,RD,GN,OE,BEBK
    598740147411.142.4117.53397108.60BK,WE,RD,GN,OE,BE,WE/BKBK
    598741148411.142.4118.87452108.60BK,WE,RD,GN,OE,BE,WE/BK,RD/BKBK
    5899211410411.142.4121.2154088.60SEE TABLEBK
    550432122651.142.5414.66237255.42BK,WEBK
    550395123651.142.5415.32287205.42BK,WE,GNBK
    550397124651.142.6716.79360165.42BK,WE,RD,GNBK
    550497125651.142.9218.77445165.42BK,WE,RD,GN,OEBK
    598745126651.142.4119.18476165.42BK,WE,RD,GN,OE,BEBK
    598746128651.142.4120.42561145.42BK,WE,RD,GN,OE,BE,WE/BK,RD/BKBK
    5504311021041.142.7915.93304303.41BK,WEBK
    5503931031041.142.7916.81375253.41BK,WE,GNBK
    5503941041041.142.6718.08461203.41BK,WE,RD,GNBK
    5508751051041.142.7919.61542203.41BK,WE,RD,GN,OEBK
    5987521071041.142.9221.46698183.41BK,WE,RD,GN,OE,BE,WE/BKBK
    * Ampacities are based on TABLE 400.5(A)(1) of the 2023 National Electrical Code and CEC Table 12

    Color Table ( / means stripe RD/WE is Red with White Stripe)

    Stock NumberSize (AWG)Conductor NumberInsulation ColorFiller/Binder
    5987301810BK,WH,RD,GN,OE,BE,WE/BK,RD/BK,GN/BK,OE/BKPoly/Paper
    5987311812BK,WH,RD,GN,OE,BE,WE/BK,RD/BK,GN/BK,OE/BK,BE/BK,BK/WEPoly/Paper
    5987321814BK,WH,RD,GN,OE,BE,WE/BK,RD/BK,GN/BK,OE/BK,BE/BK,BK/WE,RD/WE,GN/WEPoly/Paper
    5954871816BK,WH,RD,GN,OE,BE,WE/BK,RD/BK,GN/BK,OE/BK,BE/BK,BK/WE,RD/WE,GN/WE,BE/WE,BK/RDPoly/Paper
    5987331824BK,WH,RD,GN,OE,BE,WE/BK,RD/BK,GN/BK,OE/BK,BE/BK,BK/WE,RD/WE,GN/WE,BE/WE,BK/RD,WE/RD,OE/RD,BE/RD,RD/GN,OE/GN,BK/WE,WE/BK,RD/BKPoly/Paper
    5987351610BK,WH,RD,GN,OE,BE,WE/BK,RD/BK,GN/BK,OE/BKPoly/Paper
    5948891612BK,WH,RD,GN,OE,BE,WE/BK,RD/BK,GN/BK,OE/BK,BE/BK,BK/WEPoly/Paper
    5987361614BK,WH,RD,GN,OE,BE,WE/BK,RD/BK,GN/BK,OE/BK,BE/BK,BK/WE,RD/WE,GN/WEPoly/Paper
    5987371616BK,WH,RD,GN,OE,BE,WE/BK,RD/BK,GN/BK,OE/BK,BE/BK,BK/WE,RD/WE,GN/WE,BE/WE,BK/RDPoly/Paper
    5956671624BK,WH,RD,GN,OE,BE,WE/BK,RD/BK,GN/BK,OE/BK,BE/BK,BK/WE,RD/WE,GN/WE,BE/WE,BK/RD,WE/RD,OE/RD,BE/RD,RD/GN,OE/GN,BK/WE,WE/BK,RD/BKPoly/Paper
    5899211410BK,WH,RD,GN,OE,BE,WE/BK,RD/BK,GN/BK,OE/BKPoly/Paper

    Revision: 1.000.014

    Updated On: Aug. 27, 2025, 2:15 p.m. UTC