SPEC 47322

CSA 3/C CU 5KV Type SHD-GC RHINOSHIELDTM CPE Mining Cable 90°C. MSHA Approved

Flexible Copper conductors, EPR 100% Insulation Level, Cu/Nylon Braid Shield, Extra Heavy Duty Two Layer Chlorinated Polyethylene (CPE) Jacket with Optional Reflective Stripes

...

Construction:

  1. Conductor:Tin coated, soft drawn, annealed, flexible, rope-lay stranded copper per ASTM B33/B172
  2. Separator Tape:Semi-conducting tape applied between the conductor and insulation to facilitate stripping
  3. Conductor Shield:Semi-conducting cross-linked copolymer
  4. Insulation:Ethylene Propylene Rubber (EPR) 100% Insulation Level
  5. Insulation Shield:Semi-conducting cross-linked copolymer
  6. Shield Separator:Semi-conducting SBR tape applied to the phase insulation with a 50% overlap, adhesive side up
  7. Braid Shield:Tin coated, soft drawn, annealed, copper braid shield (60% minimum coverage), combined with color coded nylon (black, white, red) with a 40% maximum coverage
  8. Ground Check Conductor:Tin coated, soft drawn, annealed, rope stranded, flexible lay copper per ASTM B33/B172 with yellow, high strength, polypropylene insulation
  9. Ground Conductors:Two uninsulated, tin coated, soft drawn, annealed, rope stranded, flexible lay copper per ASTM B33/B172
  10. Tape:SBR tape applied over the cabled core for improved mechanical integrity and ease of stripping
  11. Inner Jacket:Black, mold cured, extra heavy-duty modified integral fill flame resistant, thermosetting Chlorinated Polyethylene
  12. Reinforcement:Reinforcing twine applied between the two jacket layers
  13. Outer Jacket:Black, mold cured, extra heavy-duty, flame resistant, thermosetting Chlorinated Polyethylene (CPE). Other colors available
  14. Reflective Stripe:Highly visible reflective stripe embedded into the outer jacket to increase safety and help prevent cable runover (optional, contact your sales representative for part number)

Applications and Features:

RHINOSHIELDTM Type SHD-GC is a heavy-duty trailing cable where flexibility and maximum protection is required. For use with mobile, reeling, or stationary mining equipment, continuous mining machines, longwall mining systems, and blast hole drillers. It is also an ex- cellent choice for shovels, draglines, dredges, cranes and marine shore-to-ship power supplies, and anytime extra-durable, flexible cable is required. Suitable for continuous submersion in water. Ground check conductor provides fail-safe ground monitoring. Embossed print legend for easy cable identification. Cold Bend and Impact Tested to -50°C.

Specifications:

  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors
  • CSA C22.2 No. 96 Portable Power Cables
  • ICEA S-75-381 Portable and Power Feeder Cables for Use in Mines
  • Sample Print Legend:

    SOUTHWIRE{R} RHINO{TM} BRAND CABLE XXX AWG CU 3/C EPR TYPE SHD-GC 5000V -50{D}C 90{D}C SUN RES {CSA} LL90458 FT1 FT5 P-07-KA-140005-MSHA
    Table 1 – Weights and Measurements
    Stock NumberCond. SizeCond. NumberCond. StrandsDiameter Over ConductorInsul. ThicknessDiameter Over InsulationGroundGround Check SizeGround Check StrandsGround Check Insulation ThicknessJacket ThicknessApprox. ODApprox. Weight
    AWG/KcmilNo.No.inchmilinchNo. x AWGAWGNo.milmilinchlb/1000ft
    TBA631330.211100.4962 x 108168451851.561480
    TBA432590.2561100.5422 x 88168451851.681830
    TBA332590.2851100.5712 x 78168452051.782100
    597844233080.321100.6062 x 68168602051.852234
    TBA233080.321100.6062 x 68168452051.872400
    664959133850.3551100.6312 x 58168452201.9632623
    TBA1/032730.3851100.6712 x 48168452202.083230
    6464992/033240.421100.7142 x 38168602482.173094
    TBA3/034180.5061100.7922 x 28168452352.364460
    677992^4/035320.5771100.832 x 18168603402.484649
    TBA25036080.611200.9162 x 1/06133602502.696190
    TBA30037350.6801201.0432 x 1/06133602502.816790
    TBA35038550.721201.0262 x 2/06133602652.957900
    599538^^500312210.91201.1882 x 4/06133602803.318648
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item
    ^ Reflective stripe with red jacket
    ^^ Red jacket
    Table 2 – Electrical and Engineering Data
    Cond. SizeDC Resistance @ 25°CAC Resistance @ 90°CCapacitive ReactanceInductive ReactanceWorking TensionMin Bending RadiusAllowable Ampacity In Air 90°C
    AWG/KcmilΩ/1000ftΩ/1000ftMΩ*1000ftMΩ/1000ftlbinchAmp
    60.4210.5260.0460.041179.0009.493
    40.2670.3340.0400.039285.00010.1122
    30.2120.2650.0380.038360.00010.7140
    20.1680.2100.0340.036454.00011.2159
    20.1680.2100.0340.036454.00011.2159
    10.1330.1660.0320.035572.00011.7184
    1/00.1110.1390.0300.034722.00012.5211
    2/00.0850.1060.0280.034910.00013.2243
    3/00.0670.0840.0240.0321147.00014.2279
    4/00.0530.0660.0220.0311446.00015321
    2500.0450.0560.0220.0311709.00016.1355
    3000.0370.0460.0190.0302051.00016.9398
    3500.0320.0400.0190.0302393.00017.7435
    5000.0230.0290.0160.0283418.00019.9536
    * Inductive impedance is based on non-ferrous conduit with one diameter spacing.