SPEC 48004

CU 600V LSZH XHHW-2 SOLONONplus® FT4, VW-1

SOLONONplus® 600Volt Single Conductor Copper Cross Linked Polyolefin Low Smoke Zero Halogen (XLPO LSZH) Insulation Type XHHW-2

...

Construction:

  1. Conductor:Class B compressed stranded bare copper per ASTM B3 and ASTM B8; Tinned copper per ASTM B33 available upon request
  2. Insulation:SOLONONplus® Cross Linked Polyolefin Low Smoke Zero Halogen (XLPO LSZH) Type XHHW-2

Applications and Features:

APPLICATION
Southwire’s 600 Volt SOLONONplus® Type XHHW-2 cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, and aerially when supported by a messenger. These cables are ideal for use in establishments where low smoke and low acid emissions are desired for public safety and health and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions.

FEATURES
  • The conductors are available in tinned and flexible copper stranding upon request.
  • NEC compliant
  • The halogen content is less than 0.2% and Acid gas less than 2.0%
  • UL listed VW-1
  • UL listed FT4/IEEE 1202 and ST-1
  • UL listed for CT use on 1/0 and Larger
  • -40°C Cold impact and cold bend
  • Oil Resistant I and II
  • Gasoline Resistance I and II
  • Sunlight Resistant
  • Specifications:

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • ASTM B170 Oxygen Free Electrolytic Copper (available upon request)
  • UL 44 Thermoset-Insulated Wires and Cables
  • UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test (1/0 and Larger)
  • UL 2885 Acid Gas, Acidity and conductivity of combusted materials and assessment of halogens
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • ICEA T-33-655/MIL-C-24643 Low Smoke Halogen Free (LSHF) Polymeric Jackets
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
  • RoHS-2 (European Directive 2011/65/EU)
  • ISO 9001 Quality management
  • NFPA 130 Standard for Fixed Guideway Transit and Passenger Rail Systems (#8 AWG and larger)
  • NFPA 502 Standard for Road Tunnels, Bridges, and Other Limited Access Highways
  • Sample Print Legend:

    14 AWG thru 1 AWG
    SOUTHWIRE SOLONONplus{TM} LSZH XLPO E30117 (UL) XX AWG CU TYPE XHHW-2-HF VW-1 600V PRI PRII GRI GRII -40{D}C SR FT4 ST-1

    1/0 AWG and Larger
    {SQFTG} SOUTHWIRE SOLONONplus{TM} LSZH XLPO E30117 {UL} XX AWG/KCMIL CU TYPE XHHW-2-HF VW-1 600V PRI PRII GRI GRII -40{D}C SR FT4 ST-1 CT
    Table 1 – Weights and Measurements
    Stock NumberCond. SizeStrand CountCond. CmilDiameter Over ConductorInsul. ThicknessApprox. ODApprox. WeightDC Resistance @ 25°CAC Resistance @ 75°CMax Pull Tension
    AWG/kcmilNo. of Strandscmilinchmilinchlb/1000ftΩ/1000ftΩ/1000ftlb
    66608114741100.070300.133202.6313.17033
    66608712765300.087300.151291.6622.00252
    139436107103800.113300.177431.0401.25383
    13948887165100.142450.236720.6530.786132
    13947767262400.178450.2721060.4110.495210
    13945947417400.225450.3191600.2580.310334
    13945437526200.252450.3461970.2050.246421
    13944527663600.277450.3712420.1620.154531
    139430119836900.322550.4383110.1280.154670
    1394341/0191056000.362550.4783850.1020.122845
    1394522/0191331000.406550.5224760.0810.0971065
    1394553/0191678000.456550.5725910.0640.0791342
    1394694/0192116000.498550.6147320.0510.0621693
    139453250372500000.542650.6788710.0430.0532000
    139456300373000000.594650.73010340.0360.0452400
    139457350373500000.641650.77711970.0310.0382800
    139470400374000000.685650.82113590.0270.0333200
    139475500375000000.766650.90216810.0220.0324000
    139485600616000000.840801.00820380.0180.0254800
    139486750617500000.968801.13625270.0140.0216000
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item

    Table 3 - Stock Code Colors (Black in Table 1)

    SizeRedBlueWhiteBrownOrangeYellowGrayGreenPurple
    RedBlueWhiteBrownOrangeYellowGrayGreenPurple
    14 AWG666084666076666078666079666083666077666082666080666085
    12 AWG666092666086666093666088666091666094666090666089
    10 AWG139441139435139442139437139440139443139439139438
    8 AWG139493139487139494139489139492139495139491139490
    6 AWG139482139476139483139478139481139484139480139479
    4 AWG139464139458139465139460139463139466139462139461
    2 AWG139449139444139450139446139448139451139447
    1 AWG139429139428
    1/0 AWG139433139431139432
    2/0 AWG
    3/0 AWG
    4/0 AWG139467139468
    250 KCMIL
    300 KCMIL
    350 KCMIL
    500 KCMIL139472139473139471139474
    600 KCMIL
    750 KCMIL

    Revision: 1.000.005

    Updated On: April 1, 2024, 1:43 p.m. UTC