SPEC 60200

Armorlite® Type MC THHN/THWN Circuit Size Copper Conductor Multi Circuits

Copper THHN/THWN Insulated Singles. Multiple Circuits Green Insulated Copper Grounding Conductor. UL Listed 600 Volts. Rated VW-1. Lightweight Aluminum Interlocked Armor.

...

Construction:

  1. Conductor:Solid or 19 strands class C compressed copper per ASTM B3 and ASTM B8
  2. Insulation:All phases are insulated with Polyvinyl Chloride with Nylon Sheath Type THHN/THWN
  3. Ground:Green insulated ground. Polyvinyl Chloride with Nylon Sheath Type THHN/THWN
  4. Binder:Mylar tape
  5. Armor:Aluminum Interlocked Armor

Applications and Features:

Southwire Armorlite® Type MC Cable - Multi-Circuit is suitable for use as follow:
  • Multiple circuits for branch, feeder and service power distribution in commercial, industrial, institutional, and multi-residential buildings.
  • Fished or embedded in plaster.
  • Concealed or exposed installations.
  • Environmental air-handling spaces per NEC 300.22 (C).
  • Places of Assembly per NEC 518.4 and theaters per NEC 520.5.
  • Installation in cable tray and approved raceways.
  • Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2)
  • Class I Div. 2, Class II Div 2, & Class III Div. 1 Hazardous Locations.
  • Binder tape with print legend wrapped around assembly.
  • Type THHN/THWN rated 90ºC Dry.

  • Southwire Armorlite® Type MC Cable - Multi-Circuit meets or exceeds the following requirements:
  • UL Online Product Guide Info - Metal-Clad Cable (PJAZ) ( www.ul.com )
  • Federal Specification A-A59544 (formerly J-C-30B)
  • NFPA 70 (National Electrical Code), Article 330
  • Listed for use in UL 1, 2 and 3 Hour Through Penetration Firestop Systems
  • Specifications:

  • ASTM B3 Standard Specification for Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • UL 83 Thermoplastic Insulated Wires and Cables
  • UL 1569 Metal-Clad Cables
  • UL 1479 Standard for Safety Fire Tests of Penetration Firestops
  • UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
  • Buy American: Compliant with Buy American Requirements, found in 49 U.S.C. § 5323(j); specify “Made in the USA Only!” when ordering to ensure your project receives American made 600V products.
  • REACH - European Community Regulation
  • Sample Print Legend:

    E96627 MASTER-DESIGN {UL} TYPE MC XX AWG THHN OR THWN CDRS WITH X X XX AWG NEUTRAL FOR USE IN CABLE TRAYS 600 VOLTS
    Table 1 – Weights and Measurements
    Stock NumberCond. SizeConductor NumberConductor StrandingInsulation ThicknessGround SizeDiameter Over ArmorOverall Weight
    AWG/KcmilmilsNo. x AWGinchlbs/1000ft
    555951125Solid201 x 120.590189
    690057126Solid201 x 120.590213
    563324126Solid201 x 120.590213
    690065128Solid201 x 120.665268
    596437128Solid201 x 120.665268
    586407129Solid201 x 120.763325
    6900731212Solid201 x 120.813403
    552970106Solid251 x 100.683314
    587714106Solid251 x 100.683314
    690081108Solid251 x 100.759420
    5529861012Solid251 x 100.950592
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item
    Note: Conductor number = number of phase conductors plus neutral. Does not include green ground.
    Table 2 – Electrical and Engineering Data
    Stock NumberCond. SizeMin. Bend Radius*DC Resistance at 25°CAC Resistance at 75°CAllowable Ampacity Raceway 60°CAllowable Ampacity Raceway 75°CAllowable Ampacity Raceway 90°C
    AWG/KcmilInchesΩ/1000ftΩ/1000ftAmpAmpAmp
    555951◊124.11.6622.002162024
    690057◊124.11.6622.002162024
    563324◊124.11.6622.002162024
    690065◊124.61.6622.002141721
    596437◊124.61.6622.002141721
    586407◊125.31.6622.002141721
    690073◊125.61.6622.002101215
    552970◊104.71.0401.253242832
    587714◊104.71.0401.253242832
    690081◊105.31.0401.253212428
    552986◊106.61.0401.253151720
    Ampacities have been adjusted for more than Three Current-Carrying Conductors
    Ampacities based upon 2023 NEC Table 310.16 and do not take into account the overcurrent protection limitations in NEC 240.4(D) of 15 Amps for 14 AWG CU, 20 Amps for 12 AWG CU, and 30 Amps for 10 AWG CU (independent of the conductor temperature rating and stranding). Also, see NEC sections 310.15 and 110.14(C) for additional requirements.

    Color Table

    Stock NumberCond. SizeCond. Num.12345678910111213
    555951125BlackRedBlueRed/WhiteWhiteGreen       
    690057126BlackRedBlack/WhiteRed/WhiteWhiteGreen       
    563324126BlackRedBlueBlack/WhiteRed/WhiteBlue/WhiteWhiteWhite/BlackGreen    
    690065128BlackRedBlueBlack/WhiteRed/WhiteBlue/WhiteWhiteWhite/BlackGreen    
    596437128BlackRedBlueBlack/WhiteRed/WhiteBlue/WhiteRed/BlackBlack/Red     
    586407129BlackRedBlueBlack/WhiteBlue/RedWhiteWhite/BlackWhite/RedGray/OrangeGreen   
    6900731212BlackRedBlueBlack/WhiteRed/WhiteBlue/WhiteBlue/RedWhiteRed/BlackBlack/RedWhite/BlackWhite/RedGreen
    552970106BlackRedBlack/WhiteRed/WhiteWhiteWhite/BlackGreen      
    587714106BlackRedBlueOrangePinkPurpleGreen      
    5529861012BlackRedBlueBlack/WhiteRed/WhiteBlue/WhiteBlue/RedWhiteBlack/RedWhite/BlackWhite/RedGreen

    Revision: 3.0.00C