SPEC 87006

EPEC 40 (Schedule 40) With 1250 lb Mule Tape

...

Construction:

• High-Density Polyethylene (HDPE)
• 1250 lb Mule Tape

Applications and Features:

Designed to house and protect wire and cable products in various underground applications for commercial constructions, EV infrastructure expansions, Utility grid-hardening efforts, airports, mass transit, renewables, petrochemical, agriculture, and data centers. May be installed directly buried or encased in concrete as permitted by The National Electrical Code® Article 353. For above ground applications, HDPE conduit must be encased in a minimum of 2 inches of concrete.

Specifications:

  • ASTM D3350 Standard Specification for Polyethylene Plastics Pipe and Fittings Materials
  • ASTM F2160 Standard Specification for Solid Wall High Density Polyethylene (HDPE) Conduit Based on Controlled Outside Diameter (OD)
  • UL 651A High Density Polyethylene (HPDE) Conduit
  • CSA CSA marking is available upon request
  • Buy American: Compliant with Buy American Requirements, found in 49 U.S.C. § 5323(j); specify “Made in the USA Only!” when ordering to ensure your project receives American made products.
  • NEMA TC-7 Smooth-Wall Coilable Electrical Polyethylene Conduit
  • Sample Print Legend:

    {SQFTG} FEET (LOGO) SOUTHWIRE CONDUIT (UL) HDPE X" SCH40 NEMA TC 7 / ASTM F2160 {MMM/DD/YYYY} {MACH/SHFT/OP}
    Table 1 – Physical and Electrical Data
    Stock NumberDuct Nominal SizeDuct Nominal Outside Dia.Duct Min. Wall ThicknessDuct Nominal Inside Dia.Duct Min. Bending RadiusDuct Max. Pull TensionDuct ColorApprox. Cable and Duct Weight
    inchinchinchinchinchlblb/1000ft
    6320290.751.0500.1130.80412710BLACK149
    6329980.751.0500.1130.80412710GRAY149
    6312441.001.3150.1331.029141050BLACK219
    6335681.001.3150.1331.029141050BK/3-ORG Stripes219
    6323211.001.3150.1331.029141050GRAY219
    6323441.251.6600.1401.360181420BLACK297
    6332731.251.6600.1401.360181420GRAY297
    6323451.501.9000.1451.590211700BLACK354
    6312452.002.3750.1542.047262280BLACK475
    6321122.002.3750.1542.047262280ORANGE475
    6335312.002.3750.1542.047262280BK/3-ORG Stripes475
    6336122.502.8750.2032.445323615GRAY749
    6330702.502.8750.2032.44532365RED749
    6321733.003.5000.2163.042394740BK/3-RD Stripes981
    TBA4.004.5000.2373.9985067451396
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item

    Cell Classification for HDPE Conduit

    PropertyTest MethodValue
    DensityD48830.953 g/cc
    Melt IndexD12380.25 g/10 min
    Flexural ModulusD790168,000 psi
    Tensile StrengthD6383900 yield @ 2 in/min
    SP-NCLS ESCRF2136>1000 hrs
    Hydrostatic Design BasisD2837N/A

  • (PE436580C-BK), (PE436580E-Colors)
  • Revision: 1.000.012

    Updated On: April 5, 2024, 3:39 p.m. UTC