SPEC 87010

Cable-in-Conduit (CIC) CU 600V THHN SCH 40

...

Construction:

• Manufactured by continuously extruding HDPE loosely around the cable assembly with no adhesion between the conduit and the cable, thus leaving the cables free in the conduit.
• Lubrication is applied to the cable, allowing for cables to be pulled out and replaced if necessary.
• All cables are installed as single conductors or paralleled in HDPE conduit and are available in Standard Wall, Schedule 40, Schedule 80, SDR 13.5, SDR 11, and EPEC-17.

Applications and Features:

Commonly installed from transformer to transformer or as underground cables exiting substations

Specifications:

  • ASTM D3350 Standard Specification for Polyethylene Plastics Pipe and Fittings Materials
  • ASTM D3485 Standard Specification for Coilable High Density Polyethylene (HDPE) Cable in Conduit (CIC)
  • ASTM F2160 Standard Specification for Solid Wall High Density Polyethylene (HDPE) Conduit Based on Controlled Outside Diameter (OD)
  • UL 1990 Standard for Nonmetallic Underground Conduit with Conductors
  • CSA CSA marking is available upon request
  • Buy American: Compliant with Buy American Requirements, found in 49 U.S.C. § 5323(j); specify “Made in the USA Only!” when ordering to ensure your project receives American made products.
  • NEMA TC-7 Smooth-Wall Coilable Electrical Polyethylene Conduit
  • Sample Print Legend:

    {SQFTG} FEET (LOGO) SOUTHWIRE CABLE IN CONDUIT (UL) HDPE X" SCH40 NEMA TC 7 / ASTM F2160 (NESC) {MMM/DD/YYYY} {MACH/SHFT/OP}
    Table 1 – Physical and Electrical Data
    Stock NumberDescriptionCable ColorDuct Nominal SizeDuct Nominal Outside Dia.Duct Min. Wall ThicknessDuct Nominal Inside Dia.Duct Min. Bending RadiusDuct Max. Pull TensionDuct ColorApprox. Cable and Duct Weight
    inchinchinchinchinchlblb/1000ft
    6312634 x #10 CU THHNBK, WE, RD GN0.751.0500.1130.80412710Black305
    6323743x#10 CU THHNBK, WE, GN0.751.0500.1130.80412710Black305
    6323754x#10 CU THHNBN, OE, YW, GY0.751.0500.1130.80412710Black305
    6323624x#8 CU THHNBN, OE, YW, GN1.001.3150.1331.029141050Black475
    6325454x#6 CU THHNBN, OE, YW, GN1.001.3150.1331.029141050Black607
    6334714x#4 CU THHNBN, OE, YW, GN1.251.6600.1401.360181420Black917
    6344494x1/0 AL THHNBN, OE, YW, GY1.501.9000.1451.590211700Red1029
    6345984x#3/0 CU THHN - 1x#4BN, OE, YW, GY, GN2.502.8750.2032.44532365Black3240
    6346004x#2 CU THHN - 1x#4BN, OE, YW, GY, GN2.502.8750.2032.44532365Black1855
    6345994x#1 CU THHN - 1x#4BN, OE, YW, GY, GN2.502.8750.2032.44532365Black2120
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item

    Cable Specification

    Stock NumberCable Specification
    632374 / 632375 / 632362 / 632545 / 634598 / 634600 / 634599 / 633471SPEC 10000

    Cell Classification for HDPE Conduit

    PropertyTest MethodValue
    DensityD48830.953 g/cc
    Melt IndexD12380.25 g/10 min
    Flexural ModulusD790168,000 psi
    Tensile StrengthD6383900 yield @ 2 in/min
    SP-NCLS ESCRF2136>1000 hrs
    Hydrostatic Design BasisD2837N/A

  • (PE436580C-BK), (PE436580E-Colors)
  • Revision: 1.000.013

    Updated On: Feb. 29, 2024, 11:29 a.m. UTC