SPEC 85023
Multi-Conductor CU 600 V FR-XLPE LCT Shielded Thermoplastic CPE-TP Jacket Control Cable Color Method 1 Table 1
Control Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Shielded Thermoplastic Chlorinated Polyethylene Chloride (CPE-TP) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free

Construction:
- Conductor:7 strands class B compressed bare copper per ASTM B3 and ASTM B8
- Insulation:Flame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes
- Filler:Polypropylene filler on cables with 5 or less conductors
- Binder:Polyester flat thread binder tape applied for cables with more than 5 conductors
- Shield:5 mils copper Longitudinally-Applied Corrugated Tape (LCT) shield
- Rip Cord:Rip cord for ease of jacket removal
- Overall Jacket:Thermoplastic Chlorinated Polyethylene Chloride (CPE-TP)
Applications and Features:
Southwire’s 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated construction can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.
Specifications:
Sample Print Legend:
UL Listed
SOUTHWIRE E75755 {UL} XX AWG X/C FR-XLPE XHHW-2 TYPE TC-ER CDRS 90C CPE JKT SHIELDED 600V SUN RES YEAR {SEQUENTIAL FOOTAGE MARKS} SEQ FEET
Non UL Listed
SOUTHWIRE XX AWG X/C FR-XLPE CDRS 90C CPE JKT SHIELDED 600V SUN. RES. DIRECT BURIAL YEAR SEQUENTIAL FOOTAGE MARKS SEQ FEET
Table 1 – Physical and Electrical Data
Stock Number | Cond. Size | Cond. Number | Cond. Strands | Diameter Over Cond. | Insul. Thickness | Jacket Thickness | Approx. OD | Copper Weight | Approx. Weight | DC Resistance @ 25°C | AC Resistance @ 90°C | Min Bending Radius | Allowable Ampacity At 60°C * | Allowable Ampacity 75°C * | Allowable Ampacity 90°C * | ||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AWG | No. | strands | inch | mil | mil | inch | lb/1000ft | lb/1000ft | Ω/1000ft | Ω/1000ft | inch | Amp | Amp | Amp | |||||
14 AWG | |||||||||||||||||||
603683 | 14 | 7 | 7 | 0.07 | 30 | 60 | 0.612 | 128 | 256 | 2.631 | 3.17 | 7.3 | 10 | 14 | 17 | ||||
604417 | 14 | 19 | 7 | 0.07 | 30 | 80 | 0.918 | 310 | 587 | 2.631 | 3.17 | 11 | 7 | 10 | 12 | ||||
12 AWG | |||||||||||||||||||
603689 | 12 | 2 | 7 | 0.088 | 30 | 45 | 0.452 | 74 | 138 | 1.662 | 2.002 | 5.4 | 20 | 25 | 30 | ||||
603691^ | 12 | 4 | 7 | 0.088 | 30 | 45 | 0.512 | 114 | 203 | 1.662 | 2.002 | 6.1 | 16 | 20 | 24 | ||||
627832 | 12 | 4 | 7 | 0.088 | 30 | 60 | 0.579 | 114 | 221 | 1.662 | 2.002 | 6.9 | 16 | 20 | 24 | ||||
603692 | 12 | 5 | 7 | 0.088 | 30 | 60 | 0.621 | 135 | 255 | 1.662 | 2.002 | 7.4 | 16 | 20 | 24 | ||||
603694 | 12 | 7 | 7 | 0.088 | 30 | 60 | 0.661 | 187 | 324 | 1.662 | 2.002 | 7.9 | 14 | 17 | 21 | ||||
618870! | 12 | 8 | 19 | 0.088 | 30 | 60 | 0.72 | 196 | 351 | 1.662 | 2.002 | 8.6 | 14 | 17 | 21 | ||||
603697 | 12 | 9 | 7 | 0.088 | 30 | 60 | 0.751 | 233 | 398 | 1.662 | 2.002 | 9 | 14 | 17 | 21 | ||||
603699 | 12 | 12 | 7 | 0.088 | 30 | 80 | 0.872 | 299 | 529 | 1.662 | 2.002 | 10.4 | 10 | 12 | 15 | ||||
621553! | 12 | 12 | 19 | 0.088 | 30 | 80 | 0.888 | 300 | 536 | 1.662 | 2.002 | 10.6 | 10 | 12 | 15 | ||||
10 AWG | |||||||||||||||||||
621333 | 10 | 2 | 7 | 0.113 | 30 | 45 | 0.509 | 64 | 190 | 1.04 | 1.253 | 6.1 | 30 | 35 | 40 | ||||
603701 | 10 | 2 | 7 | 0.113 | 30 | 60 | 0.566 | 103 | 198 | 1.04 | 1.253 | 6.7 | 30 | 35 | 40 | ||||
621305! | 10 | 2 | 19 | 0.113 | 30 | 60 | 0.566 | 98 | 191 | 1.04 | 1.253 | 6.7 | 30 | 35 | 40 | ||||
603702 | 10 | 3 | 7 | 0.113 | 30 | 60 | 0.593 | 135 | 249 | 1.04 | 1.253 | 7.1 | 30 | 35 | 40 | ||||
619257 | 10 | 4 | 7 | 0.113 | 30 | 60 | 0.633 | 129 | 282 | 1.04 | 1.253 | 7.5 | 24 | 28 | 32 | ||||
618685^ | 10 | 4 | 7 | 0.113 | 30 | 60 | 0.636 | 129 | 312 | 1.04 | 1.253 | 7.6 | 24 | 28 | 32 | ||||
603703^ | 10 | 4 | 7 | 0.113 | 30 | 60 | 0.636 | 162 | 292 | 1.04 | 1.253 | 7.6 | 24 | 28 | 32 | ||||
604324! | 10 | 4 | 19 | 0.113 | 30 | 60 | 0.637 | 162 | 283 | 1.04 | 1.253 | 7.6 | 24 | 28 | 32 | ||||
619436^ | 10 | 4 | 7 | 0.113 | 30 | 60 | 0.644 | 173 | 305 | 1.04 | 1.253 | 7.7 | 24 | 28 | 32 | ||||
662671^ | 10 | 5 | 7 | 0.113 | 30 | 60 | 0.685 | 161 | 353 | 1.04 | 1.253 | 8.2 | 24 | 28 | 32 | ||||
603707 | 10 | 7 | 7 | 0.113 | 30 | 60 | 0.737 | 276 | 444 | 1.04 | 1.253 | 8.8 | 21 | 24 | 28 | ||||
603709^ | 10 | 9 | 7 | 0.113 | 30 | 80 | 0.88 | 324 | 560 | 1.04 | 1.253 | 10.5 | 21 | 24 | 28 | ||||
661043% | 10 | 9 | 19 | 0.113 | 30 | 80 | 0.884 | 346 | 573 | 1.04 | 1.253 | 10.6 | 21 | 24 | 28 | ||||
603711 | 10 | 12 | 7 | 0.113 | 30 | 80 | 0.974 | 455 | 726 | 1.04 | 1.253 | 11.6 | 15 | 17 | 20 | ||||
604325! | 10 | 12 | 19 | 0.113 | 30 | 80 | 0.983 | 421 | 691 | 1.04 | 1.253 | 11.7 | 15 | 17 | 20 |
All dimensions are nominal and subject to normal manufacturing tolerances
◊ Cable marked with this symbol is a standard stock item
* Ampacities are based on Table 310.15 (B)(16) of the NEC, 2017 Edition. Ampacities of insulated conductors rated up to and including 2000 Volts, based on ambient temperature of 30°C (86°F)
^ UL Listed part number
! 19 strand combination unilay copper conductor based on ASTM B787
% Class C 19 strand compressed tinned copper per ASTM B33 and B8
^ UL Listed part number
! 19 strand combination unilay copper conductor based on ASTM B787
% Class C 19 strand compressed tinned copper per ASTM B33 and B8
Revision: 3.0.00C