SPEC 85004
Multi-Conductor CU 600 V FR-XLPE PVC Jacket Control Cable Color Method 1 Table 1
Control Cable 600 Volt Copper Conductors, Flame Retardant Cross Linked Polyethylene (FR-XLPE) Insulation Polyvinyl Chloride (PVC) Jacket, Control Cable Conductor Identification Method 1 Table 1. Silicone Free

Construction:
- Conductor:7 strands class B compressed bare copper per ASTM B3 and ASTM B8
- Insulation:Flame Retardant Cross Linked Polyethylene (FR-XLPE)
- Filler:Polypropylene filler on cables with 5 or less conductors
- Binder:Polyester flat thread binder tape applied for cables with more than 5 conductors
- Rip Cord:Rip cord for ease of jacket removal
- Overall Jacket:Polyvinyl Chloride (PVC) Jacket
Applications and Features:
Southwire’s 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.
Specifications:
Sample Print Legend:
UL Listed
SOUTHWIRE E75755 {UL} XX AWG X/C FR-XLPE (XHHW-2) CDRS 90{D}C PVC JKT 600V TYPE TC-ER SUN. RES. DIRECT BURIAL YEAR {SEQUENTIAL FOOTAGE MARKS} SEQ FEET
CSA Listed
SOUTHWIRE #P 156205 CSA XX AWG X/C FR-XLPE CDRS 90C PVC JACKET, -40C, FT-4, SUN RES, DIR BUR, 600V {MM/DD/YYYY} {SEQUENTIAL FOOTAGE MARKS} SEQ FEET
Non UL Listed
SOUTHWIRE XX AWG X/C FR-XLPE CDRS 90C PVC JACKET SUNLIGHT RESISTANT DIRECT BURIAL 600V {MM/DD/YYYY} {SEQUENTIAL FOOTAGE MARKS} SEQ FEET
Table 1 – Physical and Electrical Data
Stock Number | Cond. Size | Cond. Number | Cond. Strands | Diameter Over Cond. | Insul. Thickness | Jacket Thickness | Approx. OD | Copper Weight | Approx. Weight | DC Resistance @ 25°C | AC Resistance @ 90°C | Min Bending Radius | Allowable Ampacity At 60°C * | Allowable Ampacity 75°C * | Allowable Ampacity 90°C * | ||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AWG | No. | strands | inch | mil | mil | inch | lb/1000ft | lb/1000ft | Ω/1000ft | Ω/1000ft | inch | Amp | Amp | Amp | |||||
18 AWG | |||||||||||||||||||
624177 | 18 | 2 | 7 | 0.045 | 25 | 45 | 0.291 | 10 | 40 | 6.669 | 8.035 | 1.1 | 0 | 0 | 14 | ||||
620556 | 18 | 4 | 7 | 0.045 | 25 | 45 | 0.329 | 20 | 59 | 6.669 | 8.035 | 1.3 | 0 | 0 | 11 | ||||
14 AWG | |||||||||||||||||||
6187910 | 14 | 3 | 7 | 0.07 | 30 | 45 | 0.377 | 38 | 93 | 2.631 | 3.17 | 1.5 | 15 | 20 | 25 | ||||
619481 | 14 | 7 | 7 | 0.07 | 30 | 45 | 0.49 | 89 | 171 | 2.631 | 3.17 | 1.9 | 10 | 14 | 17 | ||||
6194830 | 14 | 9 | 7 | 0.07 | 30 | 60 | 0.595 | 115 | 231 | 2.631 | 3.17 | 2.3 | 10 | 14 | 17 | ||||
12 AWG | |||||||||||||||||||
620306 | 12 | 2 | 7 | 0.088 | 30 | 45 | 0.392 | 61 | 112 | 1.662 | 2.002 | 1.5 | 20 | 25 | 30 | ||||
6194870 | 12 | 4 | 7 | 0.088 | 30 | 45 | 0.396 | 40 | 88 | 1.662 | 2.002 | 1.5 | 16 | 20 | 24 | ||||
6194880 | 12 | 3 | 7 | 0.088 | 30 | 45 | 0.416 | 61 | 118 | 1.662 | 2.002 | 1.6 | 20 | 25 | 30 | ||||
6194890 | 12 | 4 | 7 | 0.088 | 30 | 45 | 0.453 | 81 | 151 | 1.662 | 2.002 | 1.8 | 16 | 20 | 24 | ||||
619492 | 12 | 7 | 7 | 0.088 | 30 | 60 | 0.571 | 142 | 253 | 1.662 | 2.002 | 2.2 | 14 | 17 | 21 | ||||
6042830 | 12 | 12 | 7 | 0.088 | 30 | 60 | 0.742 | 244 | 409 | 1.662 | 2.002 | 2.9 | 10 | 12 | 15 | ||||
620307 | 12 | 12 | 7 | 0.088 | 30 | 60 | 0.742 | 244 | 410 | 1.662 | 2.002 | 2.9 | 10 | 12 | 15 | ||||
10 AWG | |||||||||||||||||||
604018 | 10 | 2 | 7 | 0.113 | 30 | 45 | 0.44 | 64 | 122 | 1.04 | 1.253 | 1.7 | 30 | 35 | 40 | ||||
604282 | 10 | 2 | 7 | 0.113 | 30 | 45 | 0.44 | 64 | 134 | 1.04 | 1.253 | 1.7 | 30 | 35 | 40 | ||||
6728640 | 10 | 3 | 7 | 0.113 | 30 | 45 | 0.467 | 129 | 203 | 1.04 | 1.253 | 1.8 | 30 | 35 | 40 | ||||
620764 | 10 | 3 | 7 | 0.113 | 30 | 45 | 0.471 | 97 | 170 | 1.04 | 1.253 | 1.8 | 30 | 35 | 40 | ||||
6190880 | 10 | 4 | 7 | 0.113 | 30 | 45 | 0.51 | 129 | 208 | 1.04 | 1.253 | 2 | 24 | 28 | 32 | ||||
6042840 | 10 | 4 | 7 | 0.113 | 30 | 45 | 0.514 | 129 | 216 | 1.04 | 1.253 | 2 | 24 | 28 | 32 | ||||
6190900 | 10 | 5 | 7 | 0.113 | 30 | 60 | 0.594 | 161 | 278 | 1.04 | 1.253 | 2.3 | 24 | 28 | 32 | ||||
661859 | 10 | 7 | 7 | 0.113 | 30 | 60 | 0.64 | 226 | 354 | 1.04 | 1.253 | 2.5 | 21 | 24 | 28 | ||||
6284280 | 10 | 7 | 7 | 0.113 | 30 | 60 | 0.643 | 226 | 356 | 1.04 | 1.253 | 2.5 | 21 | 24 | 28 | ||||
6194980 | 10 | 8 | 7 | 0.113 | 30 | 60 | 0.696 | 258 | 404 | 1.04 | 1.253 | 2.7 | 21 | 24 | 28 | ||||
6730840 | 10 | 9 | 7 | 0.113 | 30 | 60 | 0.758 | 291 | 455 | 1.04 | 1.253 | 3 | 21 | 24 | 28 | ||||
6066760 | 10 | 12 | 7 | 0.113 | 30 | 80 | 0.887 | 388 | 621 | 1.04 | 1.253 | 3.5 | 15 | 17 | 20 |
All dimensions are nominal and subject to normal manufacturing tolerances
◊ Cable marked with this symbol is a standard stock item
* Ampacities are based on Table 310.15 (B)(16) of the NEC, 2017 Edition. Ampacities of insulated conductors rated up to and including 2000 Volts, based on ambient temperature of 30°C (86°F)
^ UL Listed part number
! Three striped tracers
^ UL Listed part number
! Three striped tracers
Revision: 3.0.00C