SPEC 26105
HVTECK CU 1/C 90NLEPR CB PVC AIA PVC 5kV 100% CSA
Single Conductor, 90 Mils No Lead Ethylene Propylene Rubber (NL-EPR), 100% Insulation Level, Concentric Bond, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket

Construction:
- Conductor:Class B compressed stranded bare copper per ASTM B3 and ASTM B8
- Conductor Shield:Semi-conducting cross-linked copolymer
- Insulation:90 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 100% insulation level
- Insulation Shield:Strippable semi-conducting cross-linked copolymer
- Tape Shield:5 mil tape shield
- Concentric Shield:Concentrically applied copper bond / shield wires. Complies with greater than the minimum requirement as per Table 44, CSA Standard C68.10 and Table 16A, Canadian Electrical Code Part 1
- Neutral Separator:Mylar tape
- Inner Jacket:PVC inner jacket
- Armour:Aluminum Interlocked Armour (AIA)
- Overall Jacket:Orange Polyvinyl Chloride (PVC) Jacket
Applications and Features:
Southwire's 5kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs /FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant.
Specifications:
Sample Print Legend:
{SQMTR} {CSA} SOUTHWIRE{R} POWER CABLE {NESC} MASTER-DESIGN 1/C XXX KCMIL CU X.XX mm (90 mils) NL-EPR AIA 5KV 100% INS LEVEL 25%TS CB XX X XX AWG SUN RES 105{D}C FT4 (-40{D}C) LTGG RoHS
Table 1 – Weights and Measurements
Stock Number | Cond. Size | Strand | Diameter Over Conductor | Diameter Over Insulation | Insul. Thickness | Diameter Over Insulation Shield | Concentric Neutral | Dia. Over Armour | Jacket Thickness1 | Approx. OD | Approx. Weight |
---|---|---|---|---|---|---|---|---|---|---|---|
AWG/Kcmil | No. | inch | inch | mil | inch | No. x AWG | inch | mil | inch | lb/1000ft | |
TBA | 2 | 7 | 0.282 | 0.500 | 90 | 0.560 | 7 x 14 | 1.076 | 50 | 1.176 | 767 |
TBA | 1 | 19 | 0.322 | 0.540 | 90 | 0.600 | 11 x 14 | 1.116 | 50 | 1.216 | 901 |
TBA | 1/0 | 19 | 0.361 | 0.579 | 90 | 0.639 | 11 x 14 | 1.155 | 50 | 1.255 | 994 |
TBA | 2/0 | 19 | 0.405 | 0.623 | 90 | 0.683 | 11 x 14 | 1.199 | 50 | 1.299 | 1106 |
TBA | 3/0 | 19 | 0.456 | 0.674 | 90 | 0.734 | 13 x 14 | 1.360 | 50 | 1.460 | 1285 |
TBA | 4/0 | 19 | 0.512 | 0.730 | 90 | 0.790 | 13 x 14 | 1.416 | 50 | 1.516 | 1456 |
TBA | 250 | 37 | 0.558 | 0.784 | 90 | 0.844 | 17 x 14 | 1.470 | 50 | 1.570 | 1667 |
TBA | 350 | 37 | 0.661 | 0.887 | 90 | 0.947 | 21 x 14 | 1.573 | 60 | 1.693 | 2131 |
587711 | 500 | 37 | 0.789 | 0.992 | 90 | 1.052 | 17 X 12 | 1.732 | 60 | 1.852 | 2901 |
589126 | 750 | 61 | 0.968 | 1.204 | 90 | 1.264 | 21 x 12 | 1.956 | 60 | 2.076 | 3987 |
TBA | 1000 | 61 | 1.117 | 1.353 | 90 | 1.413 | 21 x 12 | 2.157 | 60 | 2.277 | 4900 |
All dimensions are nominal and subject to normal manufacturing tolerances
◊ Cable marked with this symbol is a standard stock item
1 Comply with ICEA S-93-639 Appendix C for jacket thickness determination
Table 2 – Electrical and Engineering Data
Cond. Size | Min Bending Radius | Max Pull Tension | DC Resistance @ 25°C | AC Resistance @ 90°C | Capacitive Reactance @ 60Hz | Inductive Reactance @ 60Hz | Zero Sequence Impedance* | Positive Sequence Impedance* | Phase Short Circuit Current @ 60Hz | Allowable Ampacity In Air 90°C† | Allowable Ampacity Directly Buried 90°C‡ |
---|---|---|---|---|---|---|---|---|---|---|---|
AWG/Kcmil | inch | lb | Ω/1000ft | Ω/1000ft | MΩ*1000ft | Ω/1000ft | Ω/1000ft | Ω/1000ft | kAmp | Amp | Amp |
2 | 8.2 | 530 | 0.162 | 0.204 | 0.029 | 0.054 | 0.186 + j0.028 | 0.191 + j0.036 | 5458 | 215 | 221 |
1 | 8.5 | 669 | 0.128 | 0.162 | 0.026 | 0.052 | 0.144 + j0.025 | 0.149 + j0.033 | 8577 | 245 | 247 |
1/0 | 8.7 | 844 | 0.102 | 0.128 | 0.024 | 0.050 | 0.11 + j0.024 | 0.115 + j0.032 | 8577 | 278 | 275 |
2/0 | 9.0 | 1064 | 0.081 | 0.102 | 0.022 | 0.048 | 0.084 + j0.023 | 0.09 + j0.031 | 8577 | 317 | 306 |
3/0 | 10.2 | 1342 | 0.064 | 0.081 | 0.020 | 0.048 | 0.063 + j0.021 | 0.068 + j0.029 | 10137 | 357 | 335 |
4/0 | 10.6 | 1692 | 0.051 | 0.065 | 0.018 | 0.047 | 0.047 + j0.02 | 0.052 + j0.028 | 10137 | 404 | 369 |
250 | 10.9 | 2000 | 0.043 | 0.056 | 0.017 | 0.045 | 0.038 + j0.019 | 0.044 + j0.027 | 13256 | 456 | 412 |
350 | 11.8 | 2800 | 0.031 | 0.041 | 0.015 | 0.043 | 0.023 + j0.018 | 0.029 + j0.026 | 16376 | 537 | 456 |
500 | 12.9 | 4000 | 0.022 | 0.030 | 0.013 | 0.041 | 0.012 + j0.016 | 0.018 + j0.024 | 20275 | 616 | 497 |
750 | 14.5 | 6000 | 0.014 | 0.023 | 0.011 | 0.039 | 0.005 + j0.015 | 0.011 + j0.023 | 26018 | 706 | 551 |
1000 | 15.9 | 8000 | 0.011 | 0.019 | 0.010 | 0.038 | 0.001 + j0.014 | 0.007 + j0.022 | 26018 | 813 | 596 |
* Calculations are based on three cables triplexed / 5 mil 25 % over lapping copper tape shield / Conductor temperature of 90°C / Shield temperature of 45°C / Earth resistivity of 100 ohms-meter
† Ampacities are based on Table D17M of the 2015 Canadian Electrical Code Part I (40°C Ambient Air Temperature, indoor installation)
‡ Ampacities are based on Table D17A of the 2015 Canadian Electrical Code Part I
† Ampacities are based on Table D17M of the 2015 Canadian Electrical Code Part I (40°C Ambient Air Temperature, indoor installation)
‡ Ampacities are based on Table D17A of the 2015 Canadian Electrical Code Part I
Table 3 – Weights and Measurements (Metric)
Stock Number | Cond. Size | Strand | Diameter Over Conductor | Diameter Over Insulation | Insul. Thickness | Diameter Over Insulation Shield | Concentric Neutral | Dia. Over Armour | Jacket Thickness1 | Approx. OD | Approx. Weight |
---|---|---|---|---|---|---|---|---|---|---|---|
AWG/Kcmil | No. | mm | mm | mm | mm | No. x AWG | mm | mm | mm | kg/km | |
TBA | 2 | 7 | 7.16 | 12.70 | 2.29 | 14.22 | 7 x 14 | 27.33 | 1.27 | 29.87 | 1141 |
TBA | 1 | 19 | 8.18 | 13.72 | 2.29 | 15.24 | 11 x 14 | 28.35 | 1.27 | 30.89 | 1341 |
TBA | 1/0 | 19 | 9.17 | 14.71 | 2.29 | 16.23 | 11 x 14 | 29.34 | 1.27 | 31.88 | 1479 |
TBA | 2/0 | 19 | 10.29 | 15.82 | 2.29 | 17.35 | 11 x 14 | 30.45 | 1.27 | 32.99 | 1646 |
TBA | 3/0 | 19 | 11.58 | 17.12 | 2.29 | 18.64 | 13 x 14 | 34.54 | 1.27 | 37.08 | 1912 |
TBA | 4/0 | 19 | 13.00 | 18.54 | 2.29 | 20.07 | 13 x 14 | 35.97 | 1.27 | 38.51 | 2167 |
TBA | 250 | 37 | 14.17 | 19.91 | 2.29 | 21.44 | 17 x 14 | 37.34 | 1.27 | 39.88 | 2481 |
TBA | 350 | 37 | 16.79 | 22.53 | 2.29 | 24.05 | 21 x 14 | 39.95 | 1.52 | 43.00 | 3171 |
587711 | 500 | 37 | 20.04 | 25.20 | 2.29 | 26.72 | 17 X 12 | 43.99 | 1.52 | 47.04 | 4317 |
589126 | 750 | 61 | 24.59 | 30.58 | 2.29 | 32.11 | 21 x 12 | 49.68 | 1.52 | 52.73 | 5933 |
TBA | 1000 | 61 | 28.37 | 34.37 | 2.29 | 35.89 | 21 x 12 | 54.79 | 1.52 | 57.84 | 7292 |
All dimensions are nominal and subject to normal manufacturing tolerances
◊ Cable marked with this symbol is a standard stock item
1 Comply with ICEA S-93-639 Appendix C for jacket thickness determination
Table 4 – Electrical and Engineering Data (Metric)
Cond. Size | Min Bending Radius | Max Pull Tension | DC Resistance @ 25°C | AC Resistance @ 90°C | Capacitive Reactance @ 60Hz | Inductive Reactance @ 60Hz | Zero Sequence Impedance* | Positive Sequence Impedance* | Phase Short Circuit Current @ 60Hz | Allowable Ampacity In Air 90°C† | Allowable Ampacity Directly Buried 90°C‡ |
---|---|---|---|---|---|---|---|---|---|---|---|
AWG/Kcmil | mm | newton | Ω/km | Ω/km | MΩ*km | Ω/km | Ω/1000ft | Ω/1000ft | kAmp | Amp | Amp |
2 | 208.28 | 2359 | 0.5315 | 0.67 | 0.0088 | 0.1772 | 0.186 + j0.028 | 0.191 + j0.036 | 5458 | 215 | 221 |
1 | 215.90 | 2977 | 0.4199 | 0.53 | 0.0079 | 0.1706 | 0.144 + j0.025 | 0.149 + j0.033 | 8577 | 245 | 247 |
1/0 | 220.98 | 3756 | 0.3346 | 0.42 | 0.0073 | 0.1640 | 0.11 + j0.024 | 0.115 + j0.032 | 8577 | 278 | 275 |
2/0 | 228.60 | 4735 | 0.2657 | 0.33 | 0.0067 | 0.1575 | 0.084 + j0.023 | 0.09 + j0.031 | 8577 | 317 | 306 |
3/0 | 259.08 | 5972 | 0.2100 | 0.27 | 0.0061 | 0.1575 | 0.063 + j0.021 | 0.068 + j0.029 | 10137 | 357 | 335 |
4/0 | 269.24 | 7529 | 0.1673 | 0.21 | 0.0055 | 0.1542 | 0.047 + j0.02 | 0.052 + j0.028 | 10137 | 404 | 369 |
250 | 276.86 | 8900 | 0.1411 | 0.18 | 0.0052 | 0.1476 | 0.038 + j0.019 | 0.044 + j0.027 | 13256 | 456 | 412 |
350 | 299.72 | 12460 | 0.1017 | 0.13 | 0.0046 | 0.1411 | 0.023 + j0.018 | 0.029 + j0.026 | 16376 | 537 | 456 |
500 | 327.66 | 17800 | 0.0722 | 0.10 | 0.0040 | 0.1345 | 0.012 + j0.016 | 0.018 + j0.024 | 20275 | 616 | 497 |
750 | 368.30 | 26700 | 0.0459 | 0.08 | 0.0034 | 0.1280 | 0.005 + j0.015 | 0.011 + j0.023 | 26018 | 706 | 551 |
1000 | 403.86 | 35600 | 0.0361 | 0.06 | 0.0030 | 0.1247 | 0.001 + j0.014 | 0.007 + j0.022 | 26018 | 813 | 596 |
* Calculations are based on three cables triplexed / 5 mil 25 % over lapping copper tape shield / Conductor temperature of 90°C / Shield temperature of 45°C / Earth resistivity of 100 ohms-meter
† Ampacities are based on Table D17M of the 2015 Canadian Electrical Code Part I (40°C Ambient Air Temperature, indoor installation)
‡ Ampacities are based on Table D17A of the 2015 Canadian Electrical Code Part I
† Ampacities are based on Table D17M of the 2015 Canadian Electrical Code Part I (40°C Ambient Air Temperature, indoor installation)
‡ Ampacities are based on Table D17A of the 2015 Canadian Electrical Code Part I
Revision: 3.0.00C