SPEC 70300

Royal® SUPER EXCELENE ® WELDING CABLE UL. Silicone Free

UL Listed 600 Volt -50°C to 90°C Oil Resistant Premium Grade Orange CPE Jacket.

...

Construction:

  1. Conductor:Annealed rope-stranded Class M, bare copper conductor as per ASTM B-3. 34 AWG rope lay strand per ASTM B-172.
  2. Separator:Paper separator for ease of stripability
  3. Insulation:CPE , Orange

Applications and Features:

SOUTHWIRE Super Excelene welding cable designed for use on welding leads from the secondary side of the power source, typical for arc welders. Extra flexible lead cable, used on electrode to welder unit, battery cables and temporary or permanent lead cables. A premium-grade -50°C to 90°C Orange CPE jacket is extruded onto the cable per ASTM D-4313. Provides superior flexibility and outstanding cut, abrasion and slag resistance. Resistant to oils, solvents, water, weather and ozone.

Specifications:

  • UL Listed
  • RoHS Compliant Lead-Free, Silicone-Free
  • Sample Print Legend:

    SOUTHWIRE® ROYAL® SUPER EXCELENE® XX AWG (XX.XXmm2) WELDING CABLE E308663 (UL) 600V -50C TO +90C OIL RESISTANT -- MADE IN USA --Sequential Footage Marking--
    Table 1 – Weights and Measurements
    Stock NumberCond. SizeCond. NumberCond. StrandsJacket ThicknessApprox. ODApprox. WeightAmpacity *
    AWG/KcmilCount# x AWGmilinchlb/1000ftAmp
    64765561665900.378139105
    647656411064900.434201140
    647657211653900.488284190
    647658112090900.535348220
    6476591/0126461000.585444260
    6476612/0133251000.697542300
    6476623/0142141100.715671350
    6476634/0153201050.810824405
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item
    * Ampacities are based on TABLE 400.5(A)(1) of the 2020 National Electrical Code and CEC Table 12. The ampacity values assume a continuous sinusoidal 60 Hz current and are for reference only and should not be used as a final value.
    Table 2 – Weights and Measurements (Metric)
    Stock NumberCond. SizeCond. NumberCond. StrandsJacket ThicknessApprox. ODApprox. WeightAmpacity *
    AWG/KcmilCount# x AWGmmmmkg/kmAmp
    647655616652.299.60207105
    6476564110642.2911.02299140
    6476572116532.2912.40423190
    6476581120902.2913.59518220
    6476591/0126462.5414.86661260
    6476612/0133252.5417.70807300
    6476623/0142142.7918.16999350
    6476634/0153202.6720.571226405

    Revision: 1.000.000

    Updated On: Aug. 18, 2023, 2:40 p.m. UTC