SPEC 47302

3/C CU 2KV Type SHD-GC RHINOSHIELDTM CPE Mining Cable 90°C. CSA - MSHA Approved

Flexible Copper conductors, EPR 100% Insulation Level, Cu/Nylon Braid Shield, Extra Heavy Duty Two Layer Chlorinated Polyethylene (CPE) Jacket with Optional Reflective Stripes

...

Construction:

  1. Conductor:Tin coated, soft drawn, annealed, flexible, rope-lay stranded copper per ASTM B33/B172
  2. Separator Tape:Semi-conducting tape applied between the conductor and insulation to facilitate stripping
  3. Insulation:Ethylene Propylene Rubber (EPR) 100% Insulation Level
  4. Braid Shield:Tin coated, soft drawn, annealed, copper braid shield (60% minimum coverage), combined with color coded nylon (black, white, red) with a 40% maximum coverage
  5. Ground Conductors:Two uninsulated, tin coated, soft drawn, annealed, rope stranded, flexible lay copper per ASTM B33/B172
  6. Ground Check Conductor:Tin coated, soft drawn, annealed, rope stranded, flexible lay copper per ASTM B33/B172 with yellow, high strength, polypropylene insulation
  7. Filler:Rubber fillers as needed
  8. Tape:SBR tape applied over the cabled core for improved mechanical integrity and ease of stripping. Reinforcing twine applied between SBR tape and outer jacket
  9. Outer Jacket:Black, mold cured, extra heavy-duty, flame resistant, thermosetting Chlorinated Polyethylene (CPE). Other colors available
  10. Reflective Stripe:Highly visible reflective stripe embedded into the outer jacket to increase safety and help prevent cable runover (optional, contact your sales representative for part number)

Applications and Features:

RHINOSHIELDTM Type SHD-GC is a heavy-duty trailing cable where flexibility and maximum protection is required. For use with mobile, reeling, or stationary mining equipment, continuous mining machines, longwall mining systems, and blast hole drillers. It is also an ex- cellent choice for shovels, draglines, dredges, cranes and marine shore-to-ship power supplies, and anytime extra-durable, flexible cable is required. Suitable for continuous submersion in water. Ground check conductor provides fail-safe ground monitoring. Embossed print legend for easy cable identification. Cold Bend and Impact Tested to -50°C.

Specifications:

  • ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
  • ASTM B172 Standard Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Copper Conductors
  • CSA C22.2 No. 96 Portable Power Cables
  • ICEA S-75-381 Portable and Power Feeder Cables for Use in Mines
  • MSHA Approved
  • Sample Print Legend:

    SOUTHWIRE (R) RHINOTM BRAND CABLE # AWG CU 3/C EPR TYPE SHD-GC 2000V -50°C 90°C P-07-KA140005 MSHA
    Table 1 – Weights and Measurements
    Stock NumberCond. SizeCond. NumberCond. StrandsDiameter Over ConductorInsul. ThicknessDiameter Over InsulationGroundGround Check SizeJacket ThicknessApprox. ODApprox. WeightJacket Color
    AWG/KcmilNo.No.inchmilinchNo. x AWGAWGmilinchlb/1000ft
    569946143410.075600.2002 x 14141250.852359BK
    569653123650.094700.2352 x 12121550.950492BK
    5696541031040.117600.2402 x 12121551.000554BK
    569655831680.153700.3012 x 10101451.093740BK
    679865631330.198700.3562 x 10101651.247874BK
    649339432590.235700.4002 x 881851.3661227BK
    587868233080.302700.4662 x 781801.5351743BK
    586860133850.347800.5122 x 682351.7322249BE
    5878631/032730.354800.5572 x 482901.8502534BK
    5849072/033240.400800.5862 x 482701.9562768BK
    6413413/034180.533800.6722 x 281502.1263651BK
    5863874/035320.550800.7512 x 282602.2983873BK
    65361725036080.6821000.8162 x 1/062052.4804888BK
    64721735038550.8091000.9262 x 2/061352.7956204BK
    640977500312210.9871001.1062 x 4/061903.1899022BK
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item
    TBA stock codes are estimations only and actual product may vary. Please wait until a stock code is assigned to purchase connectors and/or fittings.
    Table 2 – Electrical and Engineering Data
    Cond. SizeDC Resistance @ 25°CAC Resistance @ 90°CInductive ReactanceWorking TensionMin Bending RadiusAllowable Ampacity In Air 90°C
    AWG/KcmilΩ/1000ftΩ/1000ftΩ/1000ftlbinchAmp
    142.8143.5550.045286.8-
    121.7742.2410.043447.6-
    101.1111.4040.038708.049
    80.7150.9030.0371128.769
    60.4500.5680.0351799.993
    40.2820.3560.03428510.9122
    20.1790.2260.03245312.2159
    10.1430.1800.03157213.8184
    1/00.1130.1430.03272214.8211
    2/00.0900.1140.03091015.6243
    3/00.0720.0910.027114717.0279
    4/00.0570.0730.029144718.3321
    2500.0480.0620.026171019.8355
    3500.0350.0460.025239422.3435
    5000.0240.0340.024342025.5536
    * Ampacities based upon ICEA S-75-381 Table H-1.