SPEC 70250

600V STOOW Cord with Jacket 105°C. Silicone Free

600 Volt, 105°C Flexible Cord. Heat and Moisture PVC Insulation and Sunlight, Heat, Moisture, Oil Resistant, and Flexible PVC Jacket. Rated for Extra Hard-Usage Service Cords. Approved for Outdoor use. Rated UL VW-1 and CSA FT1, FT2 Flame Resistant.

...

Construction:

  1. Conductor:Class K stranded bare copper per ASTM B3 and B174
  2. Insulation:Heat, moisture, and oil resistant resistant PVC (see Table 3 for insulation colors)
  3. Filler and Binder:Fillers as needed to make core round and binder as needed to keep core assembly round on certain constructions (see Table 3 for details)
  4. Jacket:Sunlight, heat, moisture, and oil resistant PVC (see Table 3 for jacket color)

Applications and Features:

Southwire Type STOOW Flexible Cords are permitted for use as specified by Article 400 and related articles of the 2020 National Electric Code. Some typical applications for Type STOOW include, but are not limited to: Washing Machines and other large appliances, heavy-duty tools, motors and temporary electrical power and lighting installations for construction sites.

Specifications:

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B174 Standard Specification for Bunch-Stranded Copper
  • UL 62 Flexible Cords and Cables
  • CSA C22.2 No. 49 Flexible Cords and Cables
  • RoHS-3 Complies with European Directive 2015/863
  • Sample Print Legend:

    (UL) VW-1 STOOW X/C XX AWG (X.XXmm2) 105(D)C DRY 60(D)C WATER RESISTANT 600V (CSA) FT1,FT2 LL90458
    Table 1 – Weights and Measurements
    Stock NumberCond. SizeCond. NumberCond. StrandsInsul. ThicknessJacket ThicknessApprox. ODApprox. WeightAmpacityInsul. ColorJacket Color
    AWG/KcmilNo.No.milmilinchlb/1000ftAmp
    5880111632630600.398710BK,WE,GNBK
    6529271636530700.4079210BK,WE,GN/YWBK
    5890561636530700.4079210BK,WE,GN/YWBK
    2074001632630750.418910BK,WE,RDBK
    6723441632630750.418910BK,WE,GNBK
    5607331642630600.4151048BK,WE,GN,RDBK
    5876221656530850.51438BK,WE,RD,OE,GN/YWBK
    5889831666530800.5351668BK,WE,RD,GN/YW,OE,BEBK
    5780581686530850.5752007BK,WE,BN,PK,BE,YW,OE,RDYW
    5889861686530800.612177BK,WE,RD,OE,BE,GN/YW,WE/BK,RD/BKBK
    20193016106530800.6592325See TableBK
    201940161265301000.692795See TableBK
    2632901434145850.5314615BK,WE,GN/YWBK
    6725381434145850.5314615BK,WE,GNBK
    5607031434145800.5315515BK,WE,GNBK
    5936281434145800.53515815BK,GN,RDBK
    5785841434145800.53515615BK,WE,GNBK
    67254012365451000.619520BK,WE,GNBK
    5607081236545950.60521020BK,WE,GNBK
    5647431246545950.66524616BK,WE,RD,GNBK
    67752210310545950.6726225BK,RD,GNBK
    631388103105451100.68326525BK,WE,GNBK
    606210104104451000.7130420BK,BK,BK,GN/YWGY
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item
    * Ampacities are based on TABLE 400.5(A)(1) of the 2023 National Electrical Code and CEC Table 12.
    TBA stock codes are estimations only and actual product may vary. Please wait until a stock code is assigned to purchase connectors and/or fittings.
    Table 2 – Weights and Measurements (Metric)
    Stock NumberCond. SizeCond. NumberCond. StrandsInsul. ThicknessJacket ThicknessApprox. ODApprox. WeightAmpacity *Insul. ColorJacket Color
    AWG/KcmilNo.No.mmmmmmkg/kmAmp
    588011163260.761.529.9112910BK,WE,GNBK
    652927163650.761.7810.3413710BK,WE,GN/YWBK
    589056163650.761.7810.3413710BK,WE,GN/YWBK
    207400163260.761.9110.4113210BK,WE,RDBK
    672344163260.761.9110.4113210BK,WE,GNBK
    560733164260.761.5210.541558BK,WE,GN,RDBK
    587622165650.762.1612.702138BK,WE,RD,OE,GN/YWBK
    588983166650.762.0313.592478BK,WE,RD,GN/YW,OE,BEBK
    578058168650.762.1614.602987BK,WE,BN,PK,BE,YW,OE,RDYW
    588986168650.762.0315.493237BK,WE,RD,OE,BE,GN/YW,WE/BK,RD/BKBK
    2019301610650.762.0316.743455See TableBK
    2019401612650.762.5417.534155See TableBK
    263290143411.142.1613.4621715BK,WE,GN/YWBK
    672538143411.142.1613.4621715BK,WE,GNBK
    560703143411.142.0313.4623115BK,WE,GNBK
    593628143411.142.0313.5923515BK,GN,RDBK
    578584143411.142.0313.5923215BK,WE,GNBK
    672540123651.142.5415.2429020BK,WE,GNBK
    560708123651.142.4115.3731320BK,WE,GNBK
    564743124651.142.4116.8936616BK,WE,RD,GNBK
    6775221031051.142.4117.0239025BK,RD,GNBK
    6313881031051.142.7917.3539425BK,WE,GNBK
    6062101041041.142.5418.0345220BK,BK,BK,GN/YWGY
    * Ampacities are based on TABLE 400.5(A)(1) of the 2023 National Electrical Code and CEC Table 12.

    Table 3 - Filler, Binder, Insulation and Jacket Colors

    Stock NumberConductor SizeConductor NumberFillerBinderInsulation ColorsJacket Color
    588011163NoneWhite Tissue PaperBlack, White, GreenWhite
    652927163NoneWhite Tissue PaperBlack, White, Green-YellowBlack
    589056163NoneWhite Tissue PaperBlack, White, Green-YellowYellow
    2074008163PolypropyleneNoneBlack, White, RedBlack
    672344163PolypropyleneNoneBlack, White, GreenBlack
    560733164PaperWhite Tissue PaperBlack, White, Green, RedYellow
    587622165PolypropyleneWhite Tissue PaperBlack, White, Red, Orange, Green-YellowYellow
    588983166PolypropyleneWhite Tissue PaperBlack, White, Red, Green-Yellow, Orange, BlueYellow
    578058168PolypropyleneWhite Tissue PaperBlack, White, Brown, Pink, Blue, Yellow, Orange, RedYellow
    588986168PVCWhite Tissue PaperBlack, White, Red, Green-Yellow, Orange, Blue, White-Black, Red-BlackYellow
    20193021610PolypropyleneMylarBlack, White, Green-Yellow, Red, Orange-Black, Green-Black, Red-Black, White-Black, Blue, OrangeYellow
    20194021612PolypropyleneMylarBlack, White, Red, Green-Yellow, Black-White, Blue-Black, Orange-Black, Green-Black, Red-Black, White-Black, Blue, OrangeYellow
    2632908143PolypropyleneNoneBlack, White, Green-YellowBlack
    672538143PolypropyleneNoneBlack, White, GreenBlack
    560703143NoneWhite Tissue PaperBlack, White, GreenYellow
    593628143NoneWhite Tissue PaperBlack, Green, RedYellow
    578584143NoneWhite Tissue PaperBlack, White, GreenYellow
    672540123PolypropyleneNoneBlack, White, GreenBlack
    560708123NoneWhite Tissue PaperBlack, White, GreenYellow
    564743124PaperWhite Tissue PaperBlack, White, Red, GreenBlack
    677522103PolypropyleneWhite Tissue PaperBlack, Red, GreenBlack
    6062109104PolypropyleneMylarBlack, Black, Green-Yellow, BlackGray