SPEC 70080

600V SEOPRENE® SEOOW Power Cord Non-UL/CSA with Black Jacket 105°C. Silicone-Free. MSHA Approved

600 Volt, 105°C Flexible Cord. Premium Oil Resistance, Sunlight, Water Resistance and Flame Retardant. Non UL / Non CSA Listed

...

Construction:

  1. Conductor:Class K stranded bare copper per ASTM B-174
  2. Insulation:Heat, moisture and oil resistant TPE
  3. Filler:Non-wicking polypropylene fillers, with a tissue-paper separator wrapped around the assembly
  4. Jacket:Black TPE (other colors available upon request)

Applications and Features:

Southwire Type SEOOW Flexible Cords are permitted for indoor and outdoor temporary power uses, portable industrial machinery and compressors. Type SEOOW Cords are suitable for use in temperatures between -50°C to maximum 105°C.

Specifications:

  • MSHA Approved
  • RoHS-3 Complies with European Directive 2015/863
  • Sample Print Legend:

    SOUTHWIRE® SEOPRENE® CORD 2/C 8 AWG (7.85mm2) SEOOW 600V - 50C TO 105C WATER RESISTANT

    Packaging:

    Standard lengths: 250', 500' and 1,000' reels. Other lengths available upon request.
    Table 1 – Weights and Measurements
    Stock NumberCCI Part #Cond. SizeCond. NumberCond. StrandsInsul. ThicknessJacket ThicknessApprox. ODApprox. WeightAmpacityInsul. ColorJacket Color
    AWG/KcmilNo.No.milmilinchlb/1000ftAmp
    55044922320839645900.70132435BK,WE,GNBK
    550450224208496451000.78341728BK,WE,RD,GNBK
    551140224708596451250.85149728BK,WE,RD,GN,OEBK
    550556223216396451250.81844145BK,WE,GNBK
    550405224216496451000.89255536BK,WE,RD,GNBK
    598330225216596451400.99268136BK,WE,RD,GN,OEBK
    598331223224396451100.91360860BK,WE,GNBK
    550404224224296451251.02780148RD,BKBK
    598333225524596451551.11796948BK,WE,RD,GN,OEBK
    5539422232323119451551.158103080BK,WE,GNBK
    5504732242324119451251.260130264BK,WE,RD,GNBK
    5505632255325119451701.395161564BK,WE,RD,GN,OEBK
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item
    * Ampacities are based on TABLE 400.5(A)(1) of the 2023 National Electrical Code and CEC Table 12.
    TBA stock codes are estimations only and actual product may vary. Please wait until a stock code is assigned to purchase connectors and/or fittings.
    Table 2 – Weights and Measurements (Metric)
    Stock NumberCCI Part #Cond. SizeCond. NumberCond. StrandsInsul. ThicknessJacket ThicknessApprox. ODApprox. WeightAmpacity *Insul. ColorJacket Color
    AWG/KcmilNo.No.mmmmmmkg/kmAmp
    5504492232083961.142.2917.8148235BK,WE,GNBK
    5504502242084961.142.5419.8962128BK,WE,RD,GNBK
    5511402247085961.143.1821.6274028BK,WE,RD,GN,OEBK
    5505562232163961.143.1820.7865645BK,WE,GNBK
    5504052242164961.142.5422.6682636BK,WE,RD,GNBK
    5983302252165961.143.5625.20101336BK,WE,RD,GN,OEBK
    5983312232243961.142.7923.1990560BK,WE,GNBK
    5504042242242961.143.1826.09119248RD,BKBK
    5983332255245961.143.9428.37144248BK,WE,RD,GN,OEBK
    55394222323231191.143.9429.41153380BK,WE,GNBK
    55047322423241191.143.1832.00193864BK,WE,RD,GNBK
    55056322553251191.144.3235.43240364BK,WE,RD,GN,OEBK
    * Ampacities are based on TABLE 400.5(A)(1) of the 2023 National Electrical Code and CEC Table 12.

    Color Code

    # of ConductorColor Sequence
    2Black, White
    3Black, White, Green
    4Black, White, Red, Green
    5Black, White, Red, Green, Orange

    Revision: 1.000.000

    Updated On: Dec. 31, 2024, 11:08 p.m. UTC