SPEC 45054

CU 600V XLPE Insulation Thermoplastic LSZH-TP Jacket. XHHW-2

Type TC-ER Control Cable 600Volt Copper Conductors, Cross Linked Polyethylene (XLPE) Insulation XHHW-2 Thermoplastic SOLONON® Low Smoke Zero Halogen (LSZH-TP) Jacket, Control Cable Conductor Identification Method 1 Table 2

...

Construction:

  1. Conductor:7 strands class B compressed bare copper per ASTM B3 and ASTM B8
  2. Insulation:Cross Linked Polyethylene (XLPE) Type XHHW-2 for cables 14 AWG or larger, 30 Mils thick for all cable sizes
  3. Filler:Polypropylene filler on cables with 5 or less conductors
  4. Binder:Polyester flat thread binder tape applied for cables with more than 5 conductors
  5. Overall Jacket:Thermoplastic SOLONON® Low Smoke Zero Halogen (LSZH-TP) Jacket

Applications and Features:

Southwire’s 600 Volt Type TC-ER control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. For uses in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. Constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10. 16 AWG wire is made in accordance with UL 66: Fixture Wire.

Specifications:

  • ASTM B3 Soft or Annealed Copper Wire
  • ASTM B8 Concentric-Lay-Stranded Copper Conductors
  • UL 44 Thermoset-Insulated Wires and Cables
  • UL 66 Fixture Wire
  • UL 1277 Electrical Power and Control Tray Cables
  • UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
  • ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2
  • ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables
  • ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
  • IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
  • Sample Print Legend:

    For 16 AWG:
    SOUTHWIRE MASTER-DESIGN {UL} AWG XX 7 CDRS TYPE TC-ER XLPE CDRS SOLONON 90C JACKET SUNLIGHT RESISTANT DIRECT BURIAL 600 VOLTS YEAR {SEQUENTIAL FOOTAGE MARKS} SEQ FEET

    For 14 AWG and larger:
    SOUTHWIRE MASTER-DESIGN {UL} AWG XX 7 CDRS TYPE TC-ER XHHW-2 CDRS SOLONON 90C JACKET SUNLIGHT RESISTANT DIRECT BURIAL 600 VOLTS YEAR {SEQUENTIAL FOOTAGE MARKS} SEQ FEET
    Table 1 – Physical and Electrical Data
    Stock NumberCond. SizeCond. NumberCond. StrandsDiameter Over Cond.Insul. ThicknessJacket ThicknessApprox. ODCopper WeightApprox. WeightDC Resistance @ 25°CAC Resistance @ 75°CMin Bending RadiusAllowable Ampacity At 60°CAllowable Ampacity 75°CAllowable Ampacity 90°C
    AWGNo.strandsinchmilmilinchlb/1000ftlb/1000ftΩ/1000ftΩ/1000ftinchAmpAmpAmp
    14 AWG
    56131214270.07030450.34925672.6313.1701.3152025
    89015914370.07030450.37350932.6313.1701.4152025
    56131314470.07030450.402511112.6313.1701.6121620
    56338314570.07030450.443641352.6313.1701.7121620
    56131414770.07030450.478891712.6313.1701.9101417
    TBA14670.07030450.492881562.6313.1701.9121620
    TBA14870.07030600.5621142122.6313.1702.2101417
    56131514970.07030600.5871152332.6313.1702.3101417
    597524141070.07030600.6491272622.6313.1702.571012
    563194141970.07030600.7742424402.6313.1703.071012
    TBA142070.07030800.8622674882.6313.1703.471012
    TBA142570.07030800.9523315902.6313.1703.86911
    TBA143070.07030801.0053956882.6313.1705.06911
    574617143770.07030801.07571912092.6313.1705.36810
    12 AWG
    57461512270.08830450.38440891.6622.0021.5202530
    89012212370.08830450.412611211.6622.0021.6202530
    56131912470.08830450.445811521.6622.0021.7162024
    57461212570.08830450.4871011801.6622.0021.9162024
    57461312770.08830600.5671422571.6622.0022.2141721
    TBA12670.08830600.5761422371.6622.0022.3162024
    TBA12870.08830600.6211822941.6622.0022.4141721
    TBA12970.08830600.6662033261.6622.0022.6141721
    TBA121070.08830600.7242233581.6622.0022.8101215
    574614121270.08830600.7322444111.6622.0022.9101215
    TBA121570.08830800.8693255351.6622.0023.4101215
    TBA122070.08830800.9574266791.6622.0023.8101215
    TBA122570.08830801.0605288271.6622.0025.391113
    TBA123070.08830801.1206309671.6622.0025.691113
    TBA123770.08830801.20877211641.6622.0026.081012
    10 AWG
    57714410370.11330450.459971661.0401.2531.8303540
    56672010470.11330450.5021292141.0401.2532.0242832
    TBA10570.11330600.5991932911.0401.2532.3242832
    TBA10670.11330600.6512263381.0401.2532.6242832
    TBA10770.11330600.6512583771.0401.2532.6212428
    TBA10870.11330600.7042904221.0401.2532.8212428
    TBA101070.11330800.8643555491.0401.2533.4151720
    574619101270.11330800.8793886291.0401.2533.5151720
    TBA101570.11330800.9865177651.0401.2533.9151720
    TBA101970.11330801.0376469301.0401.2535.1151720
    TBA102070.11330801.0906789771.0401.2535.4151720
    TBA102570.11330801.21084011931.0401.2536.0131518
    TBA103070.11330801.280100214011.0401.2536.4131518
    TBA103770.11330801.383122816931.0401.2536.9121416
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item
    *Ampacities based upon 2023 NEC Table 310.16 and do not take into account the overcurrent protection limitations in NEC 240.4(D) of 15 Amps for 14 AWG CU, 20 Amps for 12 AWG CU, and 30 Amps for 10 AWG CU (independent of the conductor temperature rating and stranding if size is present in table). Also, see NEC sections 310.15 and 110.14(C) for additional requirements.
    *Ampacities have been adjusted for more than Three Current-Carrying Conductors.

    Revision: 1.000.001

    Updated On: Aug. 18, 2023, 2:40 p.m. UTC