SPEC 70034

600V SEOPRENE® SEOOW Cord with Black Jacket 105°C. Silicone-Free

600 Volt Cord. 105°C Premium Oil Resistance, Sunlight, Water Resistance and Flame Retardant

...

Construction:

  1. Conductor:Class K stranded bare copper per ASTM B-174
  2. Insulation:Heat, moisture and oil resistant TPE
  3. Filler:Non-wicking polypropylene fillers, with a tissue-paper separator wrapped around the assembly
  4. Jacket:Black TPE (other colors available upon request)

Applications and Features:

Southwire Type SEOOW Flexible Cords UL/ CSA listed are permitted for use as specified by Article 400 and related articles of the 2020 National Electrical Code. The cable is rated -40°C to 105°C, water, oil, and weather resistant. Southwire Type SEOOW Flexible Cords are designed for extra hard usage on industrial equipment, heavy tools, battery chargers, portable lights, welding leads, marine dockside power, power extensions and mining applications.

Specifications:

  • UL 62 Flexible Cords and Cables
  • CSA C22.2 No. 49 Flexible Cords and Cables
  • Passes CSA FT2 Flame Test
  • RoHS-2 (European Directive 2011/65/EU)
  • NEC Article 400 Flexible Cords, Cables and Fixture Wire
  • Sample Print Legend:

    SOUTHWIRE® SEOPRENE® CORD X/C XX AWG (X.XXmm2) SEOOW E46194 (UL) 600V -40C TO 105C -- CSA LL90458 STOOW(TPE) 600V -50C TO 105C FT2 WATER RESISTANT

    Packaging:

    Standard lengths: 250', 500' and 1,000' reels. Other lengths available upon request.
    Table 1 – Weights and Measurements
    Stock NumberCond. SizeCond. NumberCond. StrandsInsul. ThicknessJacket ThicknessApprox. ODApprox. WeightAmpacity *
    AWG/KcmilCount# x AWGmilmilinchlb/1000ftAmp
    5505601821630600.3425210
    5505611831630650.3656410
    5514691841630600.387747
    5696451851630850.4621065
    5506341622630600.3686313
    5504021632630600.3877713
    5504641642630600.4169310
    5505551652630800.4921288
    5505621424145800.49711318
    5503981434145800.52213618
    5503991444145900.59218015
    5506261454145950.64221412
    5987391464145950.69024712
    55043212265451050.57015825
    5503951236545950.60319325
    5503971246545950.64223120
    55049712565451050.70728416
    550431102104451000.61719630
    550393103104451050.65224630
    550394104104451000.70330425
    550875105104451050.76236320
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item
    * Ampacities are based on TABLE 400.5(A)of the 2014 National Electrical Code and CEC Table 12.
    Table 2 – Weights and Measurements (Metric)
    Stock NumberCond. SizeCond. NumberCond. StrandsInsul. ThicknessJacket ThicknessApprox. ODApprox. WeightAmpacity *
    AWG/KcmilCount# x AWGmmmmmmkg/kmAmp
    550560182160.761.528.697710
    550561183160.761.659.279510
    551469184160.761.529.831107
    569645185160.762.1611.731585
    550634162260.761.529.359413
    550402163260.761.529.8311513
    550464164260.761.5210.5713810
    550555165260.762.0312.501908
    550562142411.142.0312.6216818
    550398143411.142.0313.2620218
    550399144411.142.2915.0426815
    550626145411.142.4116.3131812
    598739146411.142.4117.5336812
    550432122651.142.6714.4823525
    550395123651.142.4115.3228725
    550397124651.142.4116.3134420
    550497125651.142.6717.9642316
    5504311021041.142.5415.6729230
    5503931031041.142.6716.5636630
    5503941041041.142.5417.8645225
    5508751051041.142.6719.3554020

    Color Code

    # of ConductorColor Sequence
    2Black, White
    3Black, White, Green
    4Black, White, Red, Green
    5Black, White, Red, Green, Orange

    Revision: 3.0.00M