SPEC 70000

600V ROYAL® SOOW Cord with Black Jacket 90°C. Silicone-Free.. MSHA Approved

600 Volt 90°C Flexible Cord. Heat, Moisture and Oil Resistant EPDM Rubber Insulation, Heat, Moisture and Oil Resistant Flexible CPE Jacket.

...

Construction:

  1. Conductor:Class K stranded bare copper per ASTM B-174
  2. Insulation:Heat, moisture and oil resistant EPDM
  3. Filler:Waxed paper or rubber fillers, with a full cotton serve or paper separator wrapped around the assembly
  4. Jacket:Heat, moisture and oil resistant flexible black CPE jacket

Applications and Features:

Southwire Type SOOW Flexible Cords UL/ CSA listed are permitted for use as specified by Article 400 and related articles of the 2014 National Electrical Code. The cable is rated -40°C to 90°C, water, oil, and weather resistant. Southwire Type SOOW Flexible Cords are designed for extra hard usage on industrial equipment, heavy tools, battery chargers, portable lights, welding leads, marine dockside power, power extensions and mining applications.

Specifications:

  • UL 62 Flexible Cords and Cables
  • CSA C22.2 No. 49 Flexible Cords and Cables
  • MSHA Approved
  • MSHA flame test - P07-KA070018-1MSHA
  • Passes CSA FT2 Flame Test
  • RoHS-2 (European Directive 2011/65/EU)
  • NEC Article 400 Flexible Cords, Cables and Fixture Wire
  • Federal Specification J-C-580B
  • Sample Print Legend:

    SOUTHWIRE{R} ROYAL{R} CORD X/C X AWG (XX.X{mm2}) SOOW E46194 MASTER-DESIGN {UL} 600V -40{D}C TO 90{D}C -- {CSA} LL90458 SOOW 600V -40{D}C TO 90{D}C FT2 WATER RESISTANT {NOM}-ANCE -- {MSHA}

    Packaging:

    Standard lengths: 250', 500' and 1,000' reels. Other lengths available upon request.
    Table 1 – Weights and Measurements
    Stock NumberCCI Part #Cond. SizeCond. NumberCond. StrandsInsul. ThicknessJacket ThicknessApprox. ODApprox. WeightAmpacity *
    AWG/KcmilCount# x AWGmilmilinchlb/1000ftAmp
    5581408222251821630700.3486710
    5581428223251831630700.3708010
    5581438224251841630700.390958
    5582358305051851630950.4651348
    5600188222261622630700.3707613
    5581008223261632630700.3959413
    5581018224261642630650.42011110
    5582318305061652630950.51416210
    5581388222271424145850.50113218
    5580998223271434145900.53016518
    5581028224271444145900.57020114
    55814783050714541451050.65525414
    55813982222812265451050.58018225
    585842NA12365451150.60522125
    55809482232812365451150.60622425
    55809582242812465451050.64426620
    55810483050812565451000.70929520
    558141822229102104451050.63022230
    558097822329103104451200.66529530
    558096822429104104451050.71534724
    558103830509105104451200.77244424
    56003982231683133601250.84842640
    631387NA83133601250.84944440
    63072682259184133601550.95459632
    59696182254085133601651.03671732
    56004182239163133601950.99067555
    56004282258964133602051.07583044
    56206882239265133602151.192103644
    57005482260143427601751.13788970
    56092582247144427601651.257115256
    56206782254245427601851.395144656
    56092882249124168602051.480170676
    56206582249225168602551.716206476
    All dimensions are nominal and subject to normal manufacturing tolerances
    ◊ Cable marked with this symbol is a standard stock item
    * Ampacities are based on TABLE 400.5(A)of the 2014 National Electrical Code and CEC Table 12.
    ! Orange jacket
    ^ Color sequence: black, red, green
    Table 2 – Weights and Measurements (Metric)
    Stock NumberCCI Part #Cond. SizeCond. NumberCond. StrandsInsul. ThicknessJacket ThicknessApprox. ODApprox. WeightAmpacity *
    AWG/KcmilCount# x AWGmmmmmmkg/kmAmp
    558140822225182160.761.788.8410010
    558142822325183160.761.789.4011910
    558143822425184160.761.789.911418
    558235830505185160.762.4111.811998
    560018822226162260.761.789.4011313
    558100822326163260.761.7810.0314013
    558101822426164260.761.6510.6716510
    558231830506165260.762.4113.0624110
    558138822227142411.142.1612.7319618
    558099822327143411.142.2913.4624618
    558102822427144411.142.2914.4829914
    558147830507145411.142.6716.6437814
    558139822228122651.142.6714.7327125
    585842NA123651.142.9215.3732925
    558094822328123651.142.9215.3933325
    558095822428124651.142.6716.3639620
    558104830508125651.142.5418.0143920
    5581418222291021041.142.6716.0033030
    5580978223291031041.143.0516.8943930
    5580968224291041041.142.6718.1651624
    5581038305091051041.143.0519.6166124
    560039822316831331.523.1821.5463440
    631387NA831331.523.1821.5666140
    630726822591841331.523.9424.2388732
    596961822540851331.524.1926.31106732
    560041822391631331.524.9525.15100555
    560042822589641331.525.2127.30123544
    562068822392651331.525.4630.28154244
    570054822601434271.524.4428.88132370
    560925822471444271.524.1931.93171456
    562067822542454271.524.7035.43215256
    560928822491241681.525.2137.59253976
    562065822492251681.526.4843.59307276

    Revision: 1.000.000

    Updated On: Aug. 18, 2023, 2:40 p.m. UTC