SPEC 45061
Multi-Conductor 600 or 1000 Volt Cu (FR-XLPE) XHHW-2 Thermoplastic CPE-TP Jacket Control Cable Halo-Flex™ Type TC-ER-HL
Halo-Flex™ Type TC-ER-HL Control Cable 600 or 1000 Volt Copper Conductors, Fire Retardant Cross Linked Polyethylene (FR-XLPE) Insulation XHHW-2 -40°C Thermoplastic CPE-TP Jacket, Control Cable Conductor Identification Method 1 Table 2

Construction:
- Conductor:Flexible Stranded Rope-Lay Class K Copper per ASTM B174
- Insulation:Fire Retardant Cross Linked Polyethylene (FR-XLPE) Type XHHW-2
- Ground:Green insulated ground same size as phase conductor
- Filler:Polypropylene filler as needed to fill interstices
- Separator:Mylar for ease of stripability. Optional metal shield
- Rip Cord:Rip cord for quick removal of extruded polymeric layer and jacket
- Extruded Polymeric Layer:Extruded Polymeric Barrier Layer
- Overall Jacket:Low-Friction SIM Technology® -40°C Thermoplastic Chlorinated Polyethylene (CPE-TP) Jacket
Applications and Features:
Southwire’s Halo-Flex™ 600V TC-ER-HL or 1000V TC-ER power cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. A gas/vapor-tight polymeric sheath is extruded over the core. Rated for use in Class I, II, or III, Division 1 & 2, Zone 1 & 2, hazardous locations per NEC Article 501, 502, and 503. Listed for exposed runs in hazardous locations (TC-ER-HL) per NEC 336.10. - 40°C cold bend and cold impact. HALO-FLEX ™ CPE jacket is made with patented SIM Technology. Cable can be installed in conduit without the aid of lubrication. PATENT www.patentsw.com
Specifications:
Sample Print Legend:
(SEQ FOOTAGE) SOUTHWIRE{R} HALO-FLEX{TM} E75755 (Plant Code) {UL} XX AWG CU XX/C XHHW-2 CDRS. GW 1 X XX AWG FR-XLPE/CPE 90°C 600V TYPE TC-ER-HL OR 1000V TYPE TC-ER SUN. RES. FOR DIRECT BURIAL FT4 -40°C OIL RES I/II ABS. RoHS-3 2015/863 COMPLIANT {YYYY} 07-KA180012-MSHA
Table 1 – Physical and Electrical Data
Stock Number | Cond. Size | Cond. Number | Cond. Strands | Diameter Over Cond. | Insul. Thickness | Ground | Jacket Thickness | Approx. OD | Copper Weight | Approx. Weight | DC Resistance @ 25°C | AC Resistance @ 90°C | Min Bending Radius | Allowable Ampacity At 60°C * | Allowable Ampacity 75°C * | Allowable Ampacity 90°C * | |||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AWG | No. | strands | inch | mil | No. x AWG | mil | inch | lb/1000ft | lb/1000ft | Ω/1000ft | Ω/1000ft | inch | Amp | Amp | Amp | ||||
14 AWG | |||||||||||||||||||
679785 | 14 | 5 | 41 | 0.073 | 30 | 1 x 14 | 60 | 0.647 | 76 | 246 | 2.814 | 3.391 | 2.5 | 12 | 16 | 20 | |||
679789 | 14 | 6 | 41 | 0.073 | 30 | 1 x 14 | 60 | 0.647 | 89 | 257 | 2.814 | 3.391 | 2.5 | 12 | 16 | 20 | |||
679792 | 14 | 7 | 41 | 0.073 | 30 | 1 x 14 | 60 | 0.688 | 102 | 285 | 2.814 | 3.391 | 2.7 | 10 | 14 | 17 | |||
678159 | 14 | 8 | 41 | 0.073 | 30 | 1 x 14 | 60 | 0.728 | 115 | 311 | 2.814 | 3.391 | 2.9 | 10 | 14 | 17 | |||
12 AWG | |||||||||||||||||||
679804 | 12 | 5 | 65 | 0.094 | 30 | 1 x 12 | 60 | 0.71 | 121 | 312 | 1.774 | 2.137 | 2.8 | 16 | 20 | 24 | |||
679807 | 12 | 6 | 65 | 0.094 | 30 | 1 x 12 | 60 | 0.71 | 141 | 332 | 1.774 | 2.137 | 2.8 | 16 | 20 | 24 | |||
679810 | 12 | 7 | 65 | 0.094 | 30 | 1 x 12 | 60 | 0.757 | 162 | 371 | 1.774 | 2.137 | 3 | 14 | 17 | 21 | |||
678162 | 12 | 8 | 65 | 0.094 | 30 | 1 x 12 | 60 | 0.803 | 182 | 407 | 1.774 | 2.137 | 3.2 | 14 | 17 | 21 | |||
10 AWG | |||||||||||||||||||
679841 | 10 | 5 | 105 | 0.117 | 30 | 1 x 10 | 60 | 0.779 | 194 | 405 | 1.111 | 1.339 | 3.1 | 24 | 28 | 32 | |||
679844 | 10 | 6 | 105 | 0.117 | 30 | 1 x 10 | 60 | 0.779 | 226 | 442 | 1.111 | 1.339 | 3.1 | 24 | 28 | 32 | |||
679848 | 10 | 7 | 105 | 0.117 | 30 | 1 x 10 | 80 | 0.873 | 258 | 530 | 1.111 | 1.339 | 3.4 | 21 | 24 | 28 | |||
678165 | 10 | 8 | 105 | 0.117 | 30 | 1 x 10 | 80 | 0.927 | 291 | 583 | 1.111 | 1.339 | 3.7 | 21 | 24 | 28 |
All dimensions are nominal and subject to normal manufacturing tolerances
◊ Cable marked with this symbol is a standard stock item
† Ampacities are based on Table 310.16 of the NEC, 2020 Edition. Ampacities of insulated conductors rated up to and including 2000 Volts, based on ambient temperature of 30°C (86°F)
Revision: 3.0.00M