"Table 1 - Weights and Measurements" "" "Stock Number","Cond. Size","Conductor Number",,"Conductor Shape","Strand Count","Diameter Over Conductor","Insulation Thickness","Jacket Thickness","Approx. OD","Copper Weight","Approx. Weight" "","AWG/Kcmil","","","No. of Strands","inches","mils","mils","inches","lbs./MFT","lbs./MFT" 647083,"1/0","1","19","0.362","68","47","0.598","326","428" "TBA","250","1","TRACTION POWER CABLE","37","0.558","75","65","0.838","771","947" 644487,"350","1","TRACTION POWER CABLE","37","0.641","75","65","0.944","1081","1296" 890433,"500","1","TRACTION POWER CABLE","37","0.766","75","65","1.063","1544","1791" 585827,"500","1","TRACTION POWER CABLE","91","0.791","75","65","1.088","1544","1798" 671312,"500","1","TRACTION POWER CABLE","91","0.791","90","65","1.120","1544","1826" 669725,"500","1","TRACTION POWER CABLE","427","0.909","105","65","1.271","1610","1961" "TBA","750","1","TRACTION POWER CABLE","61","0.968","90","65","1.282","2316","2601" 563581,"750","1","TRACTION POWER CABLE","127","0.968","90","65","1.297","2315","2650" 647082,"1000","1","TRACTION POWER CABLE","127","1.118","90","65","1.450","3088","3468" "TBA","1500","1","TRACTION POWER CABLE","91","1.370","115","95","1.790","4631","5228" "TBA","2000","1","TRACTION POWER CABLE","127","1.583","115","95","2.003","6175","6852" "All dimensions are nominal and subject to normal manufacturing tolerances" "Table 2 - Electrical and Engineering Data" "Stock Number","Cond. Size","Min Bending Radius","Max Pull Tension/Rated Braking Strength","DC Resistance @ 25C","AC Resistance @ 90C","Inductive Reactance","Short Circuit Current 6 Cycles","Allowable Ampacity At 60C","Allowable Ampacity At 75C","Allowable Ampacity At 90C" "","AWG/Kcmil","inches","lbs.","ohm/MFT","ohm/MFT","ohm/MFT","Amps","Amps","Amps","Amps" 647083,"1/0","4.8","854","0.102","0.1323","0.033","","125","150","145" "TBA","250","6.7","2000","0.043","0.053","0.041","","215","255","290" 644487,"350","7.6","2800","0.031","0.039","0.040","","260","310","350" 890433,"500","8.5","4000","0.022","0.029","0.039","","320","380","430" 585827,"500","8.7","4000","0.022","0.029","0.039","","320","380","430" 671312,"500","9.0","4000","0.022","0.029","0.039","","320","380","430" 669725,"500","10.2","4000","0.022","0.029","0.039","","320","380","430" "TBA","750","10.3","6000","0.014","0.022","0.038","","400","475","535" 563581,"750","10.4","6000","0.014","0.022","0.038","","400","475","535" 647082,"1000","11.6","8000","0.011","0.018","0.037","","455","545","615" "TBA","1500","14.3","10000","0.007","0.016","0.035","","525","625","705" "TBA","2000","16.0","10000","0.005","0.016","0.034","","555","665","750"